Descrizione:
Askion azoto banco di lavoro C-Line WB zona 200.
Lavoro con lavello in acciaio inox AxLxP: 30x100x45 cm e il raffreddamento del bacino 35x45 cm.
Plexiglas conservazione dei campioni. Porta per lettore di codici a barre.
Pannello di controllo con display LCD. girevole monitor 15'' con il vettore. guanti di protezione freddi. Temperatura di esercizio fino a 100°C regolabile.
Temperature in stagno raffreddamento -130°C o opzionale 196°C con ripieno LN2.
230V. 50Hz. 1000W. Include Askion DVD prodotto. Molto buone condizioni.

Installazione

Eseguiamo l'installazione di questo dispositivo di laboratorio in modo professionale. Saremo lieti di offrirvi l'installazione di questo dispositivo di laboratorio per 680,00 € più le spese di viaggio.
Saperne di più

I sistemi di laboratorio e di analisi sono solitamente dispositivi molto esigenti con le loro specifiche e requisiti particolari. Pertanto, la messa in funzione del dispositivo di laboratorio solleva spesso la domanda su come assemblarlo, regolarlo e metterlo in funzione.

Saremo lieti di occuparci dell'installazione professionale dei vostri dispositivi di laboratorio!
Vi preghiamo di contattarci.


Beneficiate dell'installazione da parte nostra in più modi:

  • Messa in funzione immediata e senza problemi del vostro dispositivo di laboratorio
  • Un'installazione professionale prolunga la durata di vita del vostro dispositivo di laboratorio
  • Le spese di trasporto non si applicano*
  • La garanzia si estende a 3 mesi completi
  • Avete diritto alla garanzia di riacquisto Labexchange.
*sono esclusi i prodotti dei gruppi di prodotti arredamento di laboratorio e flusso laminare. In casi individuali, altri gruppi di prodotti possono essere esclusi.
Maggiori Informazioni
Objektnummer B00029829
Seriennummer 29829
Nome oggetto Askion C-Line WB 200
Fabbricante Askion
Spedizione 10-14 working days
Stato Apparecchi in stock

Gruppo prodotti: REIN

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Hersteller :            Askion

Modell:                  C-Line WB 200 / 220/230

 

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

 

The work bench consists of a cryogenic working area, that may be equipped with additionally two (WB220) or three (WB230) freezers. The work bench WB220/230 is used for defined freezing of biological material such as stem cells, blood components, tissue, semen, occytes, samples for DNA/RNA analysis, etc. The compliance of an uninterrupted cooling chain of the samples is monitored and recorded during this process.

The Integrated freezer unit, containing of up to three independently operating freezers, allows reproducible freezing processes. The freezing process can be done an the basis of freely program­mable freezing curves. lt is possible to start the individual freezers at any time without having to wait for the end of the process of the neighboring freezer. A barcode supported sample manage­ment system for sample tracking is available for the user. The work bench can be delivered also without freezer but with a big, cryogenic working area (WB200).

 

 

Technical Data WB 200, WB 220, "IE 320

 

Dimensions                                           186 x 97 x 203 cm (widht x depth x height

Electric height adjustment                     30cm adjustment range for individual, ergonomic working height

Weight                                                   300 kg (empty), 450 kg (fully loaded)

Barcode scanner                                   optional, one- or two-dimensional, lateral and bottom barcode, permanently installed

Number of freezers                                3 lift freezers (WB230), 2 lift freezers (WB220), working independently

T-range working area                            adjustable +20° down to -110°C

T-range freezer area                            +20° down to -180°C

Time to reach T-working are                max. 45 min (at -100°C working area)

T-display resolution                               0.01°C

Cooling rate freezer                               0.01 - 50 K/min

Freezing rate samples                           depending on the sample volume, sample format and sample material

control                                                   17" LCD Touchscreen-PC, mounted on an mobile support arm

Connection to LIMS/HIS                        interface by C-Line control for communication/implementation with other programmes available

Monitoring                                              integrated temperature control device, temperature sensors, connections for an external alarm system

Electrical connection                              max. power consumption 1000 W (230 V, 10 A, 50 Hz)

Coolant                                                   liquid nitrogen

Pressure liquid nitrogen supply              1,4 bar

Positive operating pressure                    0 bar

Climate conditions for use                      +15 to 25°C;  15 to 60%