Archivio

Appl.Biosystems BioCad Sprint

Seriennummer: 014150
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00014150
Seriennummer 014150
Nome oggetto Appl.Biosystems BioCad Sprint
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                   Appl.Biosystems

Modell:                BioCad Sprint

Kommentar:        Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

Overview PerSeptive Biosystems BioCAD SPRINT P TM P – System for Perfusion Chromatography is a Computer-aided chromatography system that integrates all aspects of biomolecule purification with Perfusion Chromatography technology.

The BioCAD SPRINT System is designed for:

•     Chromatographic method execution—Routine execution of chromatographic methods for the purification and analysis of biomolecules.

•     Systematic method development—The goal of method development is to optimize conditions for your application. Systematic method development makes it easy to identify variables that affect your application, systematically change the variables, observe the effects, and use the Information to optimize chromatographic conditions.

Features The BioCAD SPRINT System provides the following features:

•     Simplicity—Microsoft® Windows°-based software

that is intuitive and easy to use. You can efficiently

develop and execute separations for analytical and

preparative applications.

•     Full Process Capability—Full capability from sample injection through fraction collection, including automated column washing and regeneration.

•     Speed—Chromatographic separations in as little as one to three minutes, when using POROS® media and columns.

•     Versatility—Multiple injection mode options.

•     Gradient Capability—Six-buffer/solvent capability, with simultaneous blending between any four buffers/solvents.

•     Detection—Monitoring of pH, conductiviry, dual-wavelength UVNis absorbance, fluorescence (optional), and system pressure.

•     Templates—Predefined templates for systematic method development of some variables such as columns and sample.

•     Data Analysis—Data analysis of single data fites or groups of data fites.

•     ChromatoCADTM Scale-up Design System Software—Tool for studying the effects of changing conditions in a process method (optional).

•     Biopharmaceutical Manufacturing Software­Compliance with FDA GMP requirements (optional).

•     SCOUT Column Selector—Automated multi-column switching device that allows flow to be diverted to any one of six attached columns (optional).

Parts of the System

The BioCAD SPRINT System is shown in Figure 1-2.

The BioCAD SPRINT System includes:

•            Front panel indicators and controls

•            Buffer/solvent and pump system

•            Sample loader

•            Columns and plumbing

•            Detector and monitors

•            Fraction collection

•            Computer components

Indicators The front panel includes LED (light emitting diode) indicators:

•            Power On/Off—Indicates status of system power

•            Pump On/Off—Indicates status of pump

•            Event Mark—Indicates Status of Event Mark control

•            Lamp On/Off—Indicates status of UV/Vis detector lamp

Controls The front Panel includes push-Button controls:

•            Pump On/Off—Turns pump an and off

•            Event Mark—Marks the electronic strip Chart recorder manually with an MRK notation

•            Lamp On/Off—Turns UV/Vis detector lamp an and off

General Specifications

Condition

Specification

Weight

255 pounds (116 kg)

Dimensions

36 Inches (91 cm) deep, 72 Inches (183 cm) wide, 36 Inches (91 cm) high (space required for system, Computer monitor, keyboard, and buffers)

Pumping

system

Dual piston, positive displacement with 6 inlets, pressure safety,

and built-in seal flush

Flow rate

0.2-60 ml/min

Accuracy is +/- 1% of setpoint or 0.05 ml/min (whichever is

greater)

Maximum

system

pressure

3,000 psi (204 bar, 20.4 MPa)

Gradient

capability

Up to six solvents, with low-pressure quaternary blending in

Percentage, Eluent, or pH blend modes with 0.1% increments.

Compositional accuracy: ± 1

Sample

handling

Four injection modest

•            Manual—Eliminates prime volume, needle port adapter included

•            Pump—Unlimited volume loading

•            Integrated Autosampler (optional)—Inject from multiple samples, with complete control over autosampler functions

•            Direct Wire Autosampler (optional)—Inject from multiple samples, control autosampler from autosampler front panel

Column sizes

•            POROS° Perfusion Chromatography° columns-2.1 to 27 mm diameter

•            Conventional chromatography columns—no limit an column size

Column

configurations

One column

NOTE: Use up to six columns with optional SCOUT Column

Selector.

 

Fraction

collection

Integrated control of optional external fraction collectors, which

accommodate tubes or larger bottles. Tube-to-tube switching time is 0.1 seconds with the Advantec fraction collector.

 

Materials

Biocompatible and solvent-resistant—PEEK, Teflon®, Kel F°,

Kynar°, sapphire, stainless steel, aluminum Oxide, ruby

 

Auxiliary Inputs

and Outputs

•            Inputs-2 TTL

•            Outputs-2 TTL

 

Auxiliary driver

Outputs

•            Spareout LC-12 V (0.25 A)

•            Spareout HC-24 V (1 A)

 

Detection Specifications

Condition

Specification

Pressure

Transducer an pump discharge-0 to 3,000 psi

Auxiliary Input

12-bit A/D for additional detector

pH probe

•            Range-2 to 12 pH units

•            Flow Gell volume-50 NI

Conductivity

probe

•            Range-0 to 200 mS

•            Flow cell volume-7 pI

UVNisible

Model 201 (single wavelength)-190 nm to 800 nm

Model 205 (dual wavelength)

•            190 nm to 800 nm (single wavelength range)

•            190 to 450 nm OR 366 to 700 nm (dual wavelength ranges)

Flow cells available:

•            Analytical-6 mm path length, 9 NI volume, 45 ml/min flow rate maximum

•            Semi-prep 3 mm path length, 4.5 pI volume, 100 ml/min flow rate maximum

 

Miscellaneous Specifications

Condition

Specification

Computer

Minimum internal Pentium/100 MHz, 1.2 gigabyte hard disk drive,

16 megabyte RAM Irandom access memory), 3.5" floppy disk

drive, 14" Super VGA color monitor, keyboard, and mouse

Options

17" or 21" color monitor, laser and color printers, SCOUT Column

Selector, external detector (UV/Vis or fluorescence), fraction

collector, autosampler, 28.8K bps modern and remote control

software, Supervisorr"" Software (stand-alone software version),

Biopharmaceutical Manufacturing Software, ChromatoCAD

Scale-Up Design System Software, and kits of selected POROS

columns

Back to Top