Archivio

Analytik Jena Mercure

Seriennummer: 013854
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00013854
Seriennummer 013854
Nome oggetto Analytik Jena Mercure
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

 

Company: Analytik Jena

Model: Mercur / Mercur plus

                           

 

The following illustrations and descriptions are model-related and taken from brochures.

They do not reflect the scope of delivery of the system.

The exact scope of delivery can be found in the offer text.

 

Technical specifications

 

For Mercur Plus instruments, gold collector enrichment can be used to separate fluorescence quenching gases.

A second, downstream gold collector makes it possible to reload the enriched mercury onto the measuring gold collector.

With the second gold collector, the device meets the US EPA standard.

 

Number of significant digits displayed

3, 4 or 5 selectable

Units of concentration

mg / L, μg / mL, ng / mL, μg / L, ng / L or user defined

Signal evaluation, type of integration

Maximum value: maximum value of fluorescence intensity Integral value: time-integrated fluorescence intensity

integration time

1 to 120 s

Zero adjustment (AZ measurement time)

1 to 120 s

delay

1 to 120 s

smoothing

running average:

over 0, 2, 4, 8, 12, 16 or 20 measuring points

weighted averaging:

over 0, 5, 11, 19 or 25 measuring points

(Least squares method according to GolaySavitzky)

Results window

Alphanumeric values

Bar graph of integrated values (bar graph) Time profile of the single peak Superimposed peak graph Overview of peak gradients

Special windows

Flow report

Concentration values in the reference curve Peak curves with variable integration limits

QC window (Quality Check)

QC blank

- Blank control chart QC control samples

- Mean control chart

- Recovery control card

QC double determination sample / matrix

- difference control chart (trend control chart) - span control chart (range control chart) - precision control chart (SD control chart)

QC restocking sample

- Percent Recovery Chart

Statistical Methods

Sigma statistics

- mean value with standard deviation (SD) and relative standard deviation (RSD)

Median statistics

- median value with span (R) and relative span (R%)

confidence interval

optional: absolute, relative or switch off

selectable confidence interval:

68.3% (1 (Y) 90% (1.6 (Y) 95.4% (2 (Y) 99% (2.6 (Y) 99.7% (3 (Y) 99.9% ( 3.6 (Y)

 

calibration

calibration

Standard Calibration Input Method Recalibration Standard Addition Addition Calibration

Adjust the reference curve

linear, variable weight functions non-linear, variable weight functions

Number of standards

1 to 10

Number of addition concentrations

1 to 6

recalibration

Two-point recalibration with indication of the recalibration factor

 

power supply

 

Supply voltage frequency

230 V ± 10% 50/60 Hz

different voltage and frequency on request

network security

Installation side in the building

16 A, medium-term

input

Mercur stand-alone

mean value 130 VA

Maximum value 600 VA

(when heating the gold collector)

PC device

average value 90 VA

Maximum value 600 VA

Overvoltage category

II according to DIN EN 61010-1

pollution degree

2 according to DIN EN 61010-1

protection class

I

protection

IP 20

 

fuses

G fuse-links (5 × 20 mm 2 ) according to IEC 60127/230 V.

mains voltage

Fuses F1 and F2

230V

T 3.15 A / H

110V

T 6.3 A / H

 

Environmental conditions

working temperature

+ 10 ° C to 35 ° C

humidity

max 90% at + 30 ° C

Storage temperature (desiccant)

-25 ° C to + 55 ° C according to DIN 58390-2

 

mass and weight

 

PC device

stand-alone device

Mass [kg]

37

42

Dimensions (W x H x D) [mm]

600 x 350 x 490

600 x 555 x 490

 

Data to the control computer

computer

(Minimum)

PC Pentium with 64 MByte RAM, recommended: 128 MByte hard disk with 4 GByte

43 cm color monitor (17 ") or larger, resolution 800 x 600 pixels

CD ROM

interfaces:

- Mouse connection

- Printer connection

- A buffered RS232C interface for the Mercur

Built-in PC for stand-alone operation

VIA Eden "ProX-1215" 128MB SDRAM

IDE hard drive 3.5 ", TFT display with touchscreen, VGA color, resolution 640 x 480 pixels

printer

Inkjet Printer HP DeskJet Laser Printer HP Laser Jet

operating system

Windows XP embedded

 

Sampler AS 51 S

Sampler without dilution function, completely PC-controlled

 

Sample plate 87/15

Sample containers special containers

77 pieces, 15 mL 10 pieces, 30 mL

 

Sample plate 49/30

Sample containers special containers

39 pieces, 30 mL 10 pieces, 30 mL

power supply

over Mercur

Dimensions

5 kg

 

Sampler AS 52 S

Sampler with dilution function, completely PC-controlled

Sample plate 87/15

Sample containers special containers

77 pieces, 15 mL 10 pieces, 30 mL

Sample plate 49/30

Sample containers special containers

39 pieces, 30 mL 10 pieces, 30 mL

metering

5 mL

power supply

over Mercur

Dimensions

9 kg

 

performance parameters

  • Carrier gas flow typically 5 L / h or 10 L / h
  • Cycle time typically 40 s (without enrichment, FBR method)
  • Reaction time typically 6 s
  • Dynamic range 0.0001 to 100 g / L in 5 decades
  • Sample amount per measurement
  • Measured value processing and display
  • 1 mL (at 6 s reaction time)
  • Fluorescence intensity 0.0001 to 1.0000
  • Concentration Value range 5-digit (0.0001 to 99999 unit selectable)

 