Archivio

Amersham ÄKTA Crossflow

Seriennummer: 021469
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
GE Healthcare AKTA sistema di filtrazione tangenziale. La filtrazione e la concentrazione di proteine. Computer con WinXP pro. Stampante. Monitor. Software su supporto di distribuzione. Costruito nel 2010. Dispositivo è stato di circa 18 mesi in attività di R & S in uso. Dispositivo è dovuto alla chiusura di aziende liberamente.
siehe Storeview
Maggiori Informazioni
Objektnummer B00021469
Seriennummer 021469
Nome oggetto Amersham ÄKTA Crossflow
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

 

manufacturer:      Amersham

model:                  ÄKTA Prime

 

 

The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.

 

 

 

 

System Specifications and Operating Data

 

ÄKTAprime

Size                                        400 × 450 × 530 mm (W × D × H)

Weight                                    13 kg

Solvent compatibility              All aqueous buffers commonly used in chromatography of

biomolecules

Pump

Flow rate range                      0.1–50 ml/min

Increment                               0.1 ml/min

Pressure range                       0–1 MPa (10 bar, 145 psi)

Pressure limits                        Programmable upper limit

Viscosity                                 Up to 10 cP

 

Monitor

Absorbance range                  0.01–5 AU (full scale)

Wavelengths

with Hg lamp

(using filter selection) 254 , 280 nm (supplied)

313, 405, 436, 546 nm (optional)

with Zn lamp 214 nm

Linearity                                  <3% up to 2 AU at 254 nm

<5% up to 1 AU at 280 nm

Noise (at 254nm)                    ≤40 × 10–6 AU

Drift                                         ≤100 × 10–4 AU

Maximum pressure                 4 MPa (40 bar, 580 psi)

Flow rate                                0–100 ml/min

Optical path length                 2 mm

 

Conductivity measurement

Conductivity range                 1 μS/cm–999.9 mS/cm (IEX and HIC gradients)

 

pH measurement (optional)

pH range                                0–14 (specifications valid between 2–12)

Accuracy                                ± 0.1 pH unit, temperature compensated

Stability maximum                  0.1 pH units deviation/10 h

 

Fraction collector (with flow diversion valve PSV-50)

Tube capacity                         95 in Tube Rack 18 mm (supplied)

175 in Tube Rack 12 mm (optional)

40 in Tube Rack 30 mm (optional)

 

Environment

Ambient temperature              +4 – +40 °C

Relative humidity                    10–95% relative humidity

Atmospheric pressure            84–106 kPa (840–1060 mbar)