AMA KA-D
Objektnummer | B00012911 |
---|---|
Seriennummer | 012911 |
Nome oggetto | AMA KA-D |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Ein modernes, rechnergesteuertes System für die Cryofokussierung von thermisch desorbierten Proben, welche anschließend durch schnelle Aufheizung der Aufgabekapillare (Trap) direkt auf die Kapillarsäule des Gas-Chromatographen gegeben werden.
Der spezielle Einsatzbereich dieses Gerätes liegt darin, kleinste Probemengen aus großvolumigen Sammelgefäßen, Adsorptionsrohren und Ausdampfeinrichtungen auf kleinstem Raum zu konzentrieren.
Das Gesamt-System ist in zwei Geräteteilen aufgebaut, um den Platzbedarf am Gas-Chromatographen so gering wie möglich zu halten.
Beide Geräteteile sind mit ca. 1,5 m langen Kabeln verbunden. Das Steuergerät kann dadurch an der günstigsten Stelle am GC aufgestellt werden, ohne die Bedienung zu behindern.
Alle Arbeitsparameter werden über die Eingabetastatur und die zweizeilige VF-Anzeige eingegeben und abgespeichert. Die Funktionen können durch Tastendruck aufgerufen werden; mit den Cursortasten (links/rechts) wird die gewünschte Stelle angesprochen und der Temperatur- oder Zeitwert eingegeben. Die gesamten Daten sind im Speicher abgepuffert und bei Stromausfall oder Abschalten des Gerätes über lange Zeit erhalten.
Die Anordnung der Aufgabekapillare und somit des Säulenanschlusses in der äußersten linken Ecke des Aufgabeteils bietet die Möglichkeit, den günstigsten Aufbaupunkt am GC zu wählen.
Die Trennkapillare wird durch einen separaten, beheizten Übergang in den Säulenofen geführt.
Die Einspritzstücke bleiben so für die eigentliche Aufgabe frei und können nach Umschrauben der Säule normal benutzt werden, ohne das AMA-Aufgabeteil zu demontieren.
Technische Daten:
Zeitsteuerung: Alle Funktionen Std. : Min., nur Kurzspülung max. 60 sek.
Heizregler max.: 1 x Kühlen-Heizen KA-Stufe, 1 x Desorptionseinrichtung,
1 x Zusatzheizung oben, 1 x Säulenübergang zum GC
Schnittstelle: Anschluß Desorptions-Automat DA 816,
Anschluß je eine Kurzschluß- und eine konventionelle Heizung
Netzanschluß: 220 V 50 Hz, Leistungsaufnahme ca. 800 W
Abmessungen: Aufgabeteil B=260 / H=160 /T= 180,
Steuergerät B 340 / H = 150 / T= 380
Gewicht: ohne Desorptionseinheit ca. 13 kg