AIR 755 380
| Objektnummer | B00006875 |
|---|---|
| Seriennummer | 006875 |
| Nome oggetto | AIR 755 380 |
| Stato | Archived Product |
Gruppo prodotti: Gascromatografi con altri Detector
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
DESCRIPTION
1.1 GENERAL
The GAS CHROMATOGRAPH 755 is far more than just, a gas chromatograph. It is a self contained transportable instrument with all functions user programmable to perform your analysis in manual or fully automatic mode and record the results on an optional built-in or any other auxiliary recorder.
The control of the instrument is performed by a self contained microprocessor consisting of a central processing unit (CPU) and random access memory (RAM). Functions to be executed in the manual mode are simply selected by keyboard entry of a two digit command Code. In the automatic mode, keyboard entry of a step, time and command code sequence is stored in RAM and executed at the lapsed time indicated on the crystal controlled clock.
The Eight Digit Led display indicates all keyboard entries. facilitates editing of the stored program and displays the elapsed time and command code in the automatic mode.
In addition signal and logic outputs have been provided for interface and control of auxiliary data acquisition equipment and accessories.
1.2 SUMMARY OF GC 755 SERIES , 300-400-600-700 FEATURES
The A.I.R. Instruments 755 gas chromatograph incorporates many features not normally found in more complex and expensive laboratory and process systems. Quality components are uniquely packaged to provide optimum reliability, compactness and operational simplicity.
Although the compact design may appear to be a limiting factor, users agree this is not the case. The thoughtful mechanical design provides for the addition of many options including a variety of gas train configurations, detectors, valves and electronics.
The result is a multi-purpose instrument used by research scientists, industrial hygienist, environmental engineers and educators. The 755 is equally at home in the laboratory, industrial environment or remote field locations. Applications include the monitoring and analysis of components present in ambient air, stack gases, vehicle emissions, industrial processes, hazardous atmospheres, controlled environments, respiratory gases and specialty gas mixtures, etc.
The 755 has many standard features to reduce the need for auxiliary equipment, improve accuracy and simplify operation.
These features are:
* DISPLAY 8 digit led for indicating keyboard entries, to facilitate program editing and monitor elapsed time and commands.
* KEYBOARD for entry of all parameters.
* FUNCTION SWITCHES
CLEAR entry and initiate function
ENTER program
MANUAL event selection
AUTOMATIC event sequence
READ program stored
* ATTENUATION for manual selection of recorder range.
* ZERO for manual baseline correction.
* VALVE-DETECTOR compartment.
* FAN driven column oven accommodates packed or fused capillary columns.
* DETECTOR plug in options.
* DISPLAY DRIVER decodes the microprocessor output and drives the LED display.
* MICROPROCESSOR central processing unit and program storage.
* INTERFACE decodes the microprocessor output and enables all valve, signal, recorder and attenuation gates.
* ISOTHERMAL TENTERATURE and PROGRAMMED TEMPERATURE CONTROL
* FORCED COOL-DOWN to initial oven temperature.
* AMPLIFIER for conditioning all signals to the recorder.
* BATTERY BACK-UP to prevent the loss of program in case of power failure.
1.3 SPECIFICATIONS OF THE GC 755 SERIES 300-400-600-700
AMPLIFIER
* Push button range and attenuation
* Automatic and manual zero
* Programmable detector Signal selection
* Noise less than @ 0.5 % full scale
* Linearity @ 1 % of Pull scale
* Programmable attenuation of 7 windows
VALVE
* 10 Port multi functional pneumatically operated with dual solenoid valve (Standard)
* 1/16" Stainless steel fittings and body
* Ceramic filled teflon TM rotor assembly
* 3.0 Bar actuation pressure
* Maximum operating temperature 175° C
OVEN
* Volume 2.4 dm 3 dimensions 17.5 x 18.5 x 7.5 cm ( WxDxH)
* Column temperature from 30° to 180° C, isothermal or temperature programmed
* Up to 10 temperature programs may be stored
* Column temperature control @ 0.1° C and overheating protection
* Forced cool-down by pneumatical operated shutter an the rear side
* Spiral winded kanthal wired heating element with "K" type thermocouple Sensor
* Additional isothermal temperature zone controllers are optional
DETECTORS (optional)
* Flame Ionisation Detector (FID) with 1 ppm full scale sensitivity for methane
* Photo Ionisation Detector (PID) with 0.1 ppm full scale sensitivity for vinylchloride
* Thermal Conductivity Detector (TCD) with 0.2 % sensitivity fsd for n-butane, WX filaments
* Electron Capture Detector (ECD) an request
* Flame Photometric Detector (FPD) an request
RECORDER (optional)
* Built-in model
* Fibre tip pen cartridge
* 60 mm Z-fold chart, convenient front loading
* Chart Speed 15" per hour (standard)
* Accuracy including linearity @ 1 % of full scale and dead band @2% of full scale
* Response 2.0 seconds for full scale travel
PHYSICAL
* Weight 9 kg, dimensions 32 x 19 x 40 cm ( WxHxD)
" Portable case configuration, 19" rack mounting optional
* Blue case with handle and easy snap-off cover clamps
* Black front and back panel with white lettering
POWER
* 220 VAC 50 Hz (@ 10% deviation), 110 VAC 60 Hz and 110 VAC 50 Hz optional
* Consumption @ 150 VA isothermal operated, maximum 350 VA when temperature programmed