Agilent G1888A Headspace
Objektnummer | B00018531 |
---|---|
Seriennummer | 018531 |
Nome oggetto | Agilent G1888A Headspace |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
manufacturer : Agilent
model : G 1888 A
annotation : Dokumente engl .
Specifications
Sample Capacity
Holds 70 vials in tray. Twelve position oven for optimized sample overlapping constant time heating.
Sample Vials
Standard crimp top or screw cap vials, 20 mL , 10 mL . No adaptor required for 10-mL sample vials.
Mode of Operation
Shaking with choice of off, low, or high.
Constant heating time (CHT) mode for each sample. Overlapping up to 12 vials for maximized sample throughput
Multiple headspace extraction (MHE) mode with up to 100 extractions per vial for method development and validation or for analysis of sample in unusual matrices
Multiple headspace extraction concentration (MHC) mode , with up to 10 extractions from 1 vial made followed by one GC start after the last extraction to increase sensitivity
Zone Temperature
All temperature zones can be set off
Oven heating: 40 °C to 230 °C in
1 °C increments;
0.5999 min in
0.1 min increments
Loop/Valve: 45 °C to 250 °C
Transfer line: 50 °C to 250 °C
Sample Pathway
Inert deactivated path from sample needle to transfer line. Transfer line length: 85 cm. Sample loop: 1 mL (standard), 3 mL (option)
Pneumatic Control
In-unit switch connection between:
Built-in manual pneumatics (pressure regulator and flow controller) and GC built-in electronic pneumatic control (EPC)
Interfacing with GC
Volatile inlet (VI) or other standard GC inlet
Communication
LAN; RS-232; Remote start/stop
System Control
Control and monitoring by full function control keypad and built-in multiline display. Features:
Parameter set up
Store up to four user defined headspace methods (there are also five preset methods)
Detailed power-on self test
Built-in leak test routine
Update firmware via LAN or RS-232
Monitor set and actual values, as well as, operation status
GC ChemStation
Complete integration/control with the GC ChemStation , (G2070AA - A.09.03 or later) and headspace control SW (G2922AA). Headspace parameters are part of a GC method. Using a GC ChemStation sequence table to track sample from sampling to analysis. Event log function records every step of headspace events. FDA 21 CFR part 11 compliant. (Must also order ChemStation Plus Security Pack separately.)
Dimensions and Weight
Height: 55.5 cm (21.6 in)
Width: 46.0 cm (18.1 in)
Depth: 63.5 cm (25.0 in)
Average weight: 46.3 kg (102 lb)
Environmental Conditions
Operation: 10 °C to 35 °C
Storage: 40 °C to 70 °C
Humidity: 5% to 95%
Line voltage: 100240 V ±10%
Power required: 750 VA maximum