Usually, laboratory and analysis devices are very exigent system with a very own specifications and requirements. Therefore, the startup of a laboratory device often rises the question how to assemble, adjust and to launch it.
We would be pleased to take over the professional installation of your laboratory devices!Please contact us.
Benefit from the installation by us in more than one way:
All guarantee services for you
optional guarantee services bring even more safety
optional installation of equipment for immediate and safe use of equipment
We shall be glad to answer your questions regarding this device
Attractive rental and leasing offers conserve your budget
Use our free call-back-function
Se si acquista questo articolo usato anziché nuovo, si risparmia tanta CO2 quanta se ne percorre 410 km con un'auto a benzina.
Garanzia:Tutti gli strumenti utilizzati da Labexchange sono soggetti a verifiche ed ispezioni prima della consegna che avverrà solo nel caso essi risultino perfettamente funzionanti. La verifica e la funzionalità sono documentate da un rapporto di una società di servizio indipendente. La Labexchange Fullguarantee è di 60 giorni. (Valido per i paesi all'interno dell'UE e CH) Certificato di funzionamento:La verifica della funzionalità dei nostri strumenti è documentata oltre che dal rapporto di servizio anche da un certificato di funzionamento.Garanzia:Il periodo di garanzia dei nostri strumenti è di 24 mesi dalla data di consegna.
On demand, we verify the option of an extension of warranty for your device. If possible, the period of warranty is 6 months for 10 % extra charge and 1 year for 20 % extra charge on the list price. (Valid for DE, AT, CH, FR, NL, BE, LU, GB and IR)
Play it safe! We are pleased to offer you the installation of your laboratory equipment. Our qualified technicians install the device on your desired date in the laboratory, so that you can work quickly and safely with your new laboratory equipment.
The installation of the equipment by Labexchange brings further advantages. You thereby obtain a guarantee extension to 3 months and you have also the right to the Labexchange Repurchase Guarantee.
You receive sensible laboratory equipment and analytical systems as well as much of the available laboratory hoods, already incl. installation.
* Campi obbligatori
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country
Possible payment methods
Comment
DE, AT, CH
Payment by invoice, payment in advance
Payment by invoice is only possible for corporate clients.
NL, BE, LU
Payment by invoice is only possible for corporate clients
Other countries
Payment in advance
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
All articles are used articles, except an article is listed especially as a new device.
Status
Condition
Immediately available
Used
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.
Published
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.
New device
new
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.
Modell: G 1377A
Kommentar: Dokumente engl.
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
Four models of Agilent 1100 Series well-plate sampler are available :
G1367A Well-plate sampler
G1368A Thermostatted well-plate sampler
G1377A Micro well-plate sampler
GI378A Thermostatted micro well-plate sampler
The Agilent 1100 Series well-plate samplers and Agilent 1100 Series thermostatted well-plate samplers are designed for use with other modules of the Agilent 1100 Series LC system, with the HP 1050 Series, or with other LC Systems if adequate remote control Inputs and Outputs are available. The wellplate samplers are controlled from the Agilent 1100 Series control module or from the Agilent ChemStation for LC.
The special-designed thermostattable sample tray for this Instrument holds 2 well-plates (shallow - or deepwell) and additional 10 x 2.0 ml vials. The format of the well-plates can be up to 384 wells per plate (on a footprint of 128x86 mm). The well-plate sampler can also handle 100 x 2 ml vials using the current trays for the Agilent Gl313/29A autosampler. There are Sensors to detect the presence of the tray.
The well-plate sampler transport mechanism uses an X-Z-theta robot to optimize the positioning of the sampling arm on the well-plate. Once the sampling arm is positioned over the programmed sample position, the programmed sample volume is drawn by the metering device into the sampling needle. The sampling arm then moves to the injection position where the sample is flushed onto the column.
The well-plate sampler employs a vial/plate pusher mechanism to hold down the vial or the plate while the needle is drawn back from the sample vessel (a raust in the case a septum is used). This vial/plate pusher employs a Sensor to detect the presence of a plate. All axes of the transport mechanism
(x-,z-,theta-robot) are driven by Stepper-motors. Optical encoders ensure the correct Operation of the movement.
The standard metering device (for the G1367A/68A) provides injection volumes from 0.1-100 µl. A multi-draw kit extends the range up to 1500 µl. The micro metering device (for the G1377A/78A) provides injection volumes from 0.01 - 8µl with the standard loop capillary installed and from 0.01 - 40 µl with the extended loop capillary. The metering device is always flushed by the mobile phase after injection for minimum internal carry-over.
An additional needle flush station with a peristaltic pump is installed to wash the outside of the needle. This reduces the already low carry-over for very sensitive analysis. The bottle containing the mobile phase for the wash procedure will be located in the solvent bottle cabinet. Produced waste during this Operation is channeled safely away through a waste drain.
The six-port (only 5 ports are used) injection valve unit is driven by a high-Speed hybrid Stepper motor. During the sampling sequence, the valve unit bypasses the autosampler, and connects flow from the pump to the column directly. During injection and analysis, the valve unit directs the flow through the well-plate sampler which ensures that all of the sample is injected onto the column, and that the metering unit and needle are always free from sample residue before the next sampling sequence begins. The injection valves from the G1367A/68A and the G1377A/78A have a different stator head and a different rotor seal. The volume of each valve is different.
Control of the vial/plate temperature in the thermostatted well-plate sampler is achieved using an additional Agilent 1100 Series module; the ALS thermostat.
The ALS thermostat contains Peltier-controlled heat-exchangers. A fan draws air from the area above the sample vial tray of the well-plate sampler. It is then blown through the fins of the cooling/heating module. There it is cooled or heated according the temperature setting. The thermostatted air enters the well-plate sampler through a recess underneath the special designed sample tray. The air is then distributed evenly through the sample tray ensuring effective temperature control, regardless of how mang vials are in the tray. In cooling mode condensation is generated an the cooled side of the Peltier elements. This condensed water is safely guided into a waste bottle for condensed water.
Performance Specifications Agilent 1100 Series Micro Well Plate Sampler
GLP features Early maintenance feedback (EMF), electronic records of maintenance and
errors
Communications Controller-area network (CAN). RS232C, APG-remote standard, optional
fourexternal contactclosures and BCDvial numberoutput
Safety features Leak detection and safe leak handling, low voltages in maintenance areas,
error detection and display
Injection range 0.01 8 µl in 0.01 µl increments with the small loop capillary
0.01 40 µl in 0.01 µl increments with the extended loop capillary
Precision Typically < 0.5 % RSD of peak areas from 5 40 µl,
Typically < 1 % RSD from 1 5 µl
Typically <3 % RSD from 0.2-1 µl
Sample viscosity range 0.2 5 cp
Sample capacity 2 X well-plates (MTP) + 10 X 2 ml vials
100 x 2 ml in one tray
40 x 2 ml in half tray
lnjection cycle time Typically < 30 s using following standard conditions:
Default draw speed: 4 µl/min
Default eject speed: 10 µl/min
Injection volume: 0.1 µl
Carry-over Typically < 0.05 % using the following conditions:
Column:150 x0.5 mm Hypersil ODS, 3 pm
Mobile phase: Water/Acetonitrile = 85/15
Column Flovv rate: 13 µl/min
Injection volume:1 µl caffeine (=25ng caffeine),1 µl water to test carryover
Outside wash of needle before injection: 20 sec with water using flush port
Physical Specifications - sampler (G1367A / G1377A)
Type Specification Comments
Weight 15.5 kg (34.2 Ibs)
Dimensions 200 x 345 x 440 mm
(height x width x depth) (8 x 13.5 x 17 inches)
Line voltage 100 240 VAC, ±10 % Wide-ranging capability
Line frequency 50 or 60 Hz, -±5 %
Power consumption (apparent power) 300 VA Maximum
Power consumption (active power) 200 VV Maximum
Ambient operating temperature 4 to 55 °C (41 to 131 °F)
Ambient non-operating temperature -40 to 70 °C (-4 to 158 °F)
Humidity < 95 %, at 25 to 40 °C(77 to 104 °F) Non-condensing
Operating Altitude Up to 2000 m (6500 ft)
Non-operating altitude Up to 4600 m (14950 ft) For storing the
autosampler
Safety standards: IEC, CSA, UL Installation Category II, Pollution Degree 2
Optional with G1330B Thermostat
lntroduction to the Thermostatted Autosampler
The Agilent 1100 Series autosampler is designed for use with other modules of the Agilent 1100 Series LC System, with the HP 1050 Series, or with other LC Systems if adequate remote control Inputs and Outputs are available. The autosampler is controlled from the Agilent 1100 Series control module or from the Agilent ChemStation for LC Systems.
The specially-designed thermostattable Sample trays holds Bither 100 x 1.8 ml vials or two wellplates and 10 x 1.8 ml vials.
The ALS thermostat contains Peltier-controlled heat exchangers. A fan draws air from the area above the sample vial trag of the autosampler and is then blown through the fins of the cooling/heating module. There it is cooled or heated according to the temperature setting. The thermostatted air enters the autosampler through a recess underneath the specially-designed sample tray. The air is then distributed evenly through the Sample tray ensuring effective temperature control, regardless of how many vials are in the tray.
In cooling mode condensation is generated an the cooled side of the Peltier elements. This condensed water is safely guided into the leak System.
Thermostat
Weight 20.7 kg (45.6 Ibs)
Dimensions 140 x 345 x 435 mm
(height X width X depth) (5.5 x 13.5 x 17 inches)
Line voltage 100 - 120 or 220 - 240 VAC, ± 10 % Automatic selection
Line frequency 50 or 60 Hz, ± 5%
Power consumption Autosampler: 300 VA Maximum
ALS Thermostat: 260 VA Maximum
Ambient operating temperature 4. 40°C (41 - 131°C) see an page 22
Ambient nun-operating temperature -40 70 °C (-4 - 158 °C)
Humiuity < 95 %, at 25 - 40°C (77 - 104 °C) Non-condensing;
Operating Attitude Up to 2000 m (6500 ft)
Safety standards: IEC, CSA, UL, EN Installation Category II, Pollution Degree 2