Archivio

Agilent G 1321 A

Seriennummer: 013072
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00013072
Seriennummer 013072
Nome oggetto Agilent G 1321 A
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Agilent

Modell:            G 1321 A

Kommentar:   Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

Agilent 1100 Series Fluorescence Detector

Optimized sensitivity and selectivity, for reliable quantitative and qualitative information

The Agilent 1100 Series fluorescence detector provides high-sensitivity multisignal detection, online fluorescence spectra, straightforward Operation and maintenance, and built-in features for GLP compliance.

•            Simplified optical design for optimized baseline stability.

•            Long-life Xenon lamp for highest sensitivity.

•            Variable-mode monochromators for selective multisignal detection and

online spectra acquisition.

•            Easy front access to flow cell for fast inspection or exchange.

Increase selectivity with multisignal detection

The monochromators work in signal or spectral mode and are synchronized with the flash lamp to allow single or multi­signal detection of up to four different excitation and emission wavelengths.

Get spectra and quantitative data from a single run

View online spectra without interrupting your chromatography. Excitation or emission spectra are acquired in just tenths of a second. Save all the data for postrun review.

Quantitative information in trace analyses

The optical design guarantees lowest stray-light performance for optimized baseline stability. A Jong-life (>4000 hours) flash lamp, lamp reference system and efficient Iight collection ensures constant lamp energy for maximum excitation of fluorophores.

Check or exchange your flow cell—fast

Plus automatic recognition of all flow cell cartridges provides documentation of instrument parameters and helps you to comply with GLP.


Specifications

Detection type:                        Multisignal fluorescence detector with rapid online scanning capabilities and spectral data analysis

Performance:                          10 fg anthracene LOD, Ex 250 nm, Em 400 nm*, Raman (H 2 0) >400 Ex 350 nm, Em 397 nm, dark value 450 nm, standard flow cell

Light source:                                       Xenon flash lamp, normal mode (20W) and economy mode (5W)

Pulse frequency:                     296 Hz for signal mode, 74 Hz for economy mode

Excitation monochromator:    Concave holographic grating, F/1.6, blaze 300 nm, range 200—700 nm and zero-order, bandwidth 20 nm

Emission monochromator:     Concave holographic grating, F/1.6, blaze 400 nm, range 280—900 nm and zero-order, bandwidth 20 nm

Reference system:                 Inline excitation measurement

Time programing:                    Up to 4 signals, response time, PMT gain, baseline behaviour (append, free, zero), spectral parameters

Spectral acquisition:                Excitation or emission spectra, scan speed 28 ms per datapoint, e.g. 0.6 s per spectrum 200—400 nm, 10 nm step

Step size:                                1—20 nm

Spectra storage:                     Limited only by disk space

Wavelength repeatability:        ±0.2 nm

Wavelength accuracy:            ±3 nm

Flow cells:                               Standard: 8 µl volume, 20 bar (2 MPa) pressure maximum, quartz

                                               Optional: fluorescence cuvette for offline spectroscopic measurements with 1 ml syringe, 8 µl volume, quartz

Control and data evaluation: Agilent ChemStation for HPLC or Agilent 1100 Series control module with limited spectral data analysis and printing of spectra

Analog outputs:                       Recorder/integrator: 100 mV or 1 V, output range >10 2 luminescence units, 2 outputs

Communications:                    Controller-area network (CAN), HP-IB, RS-232C, LAN, APG Remote: ready, start, stop and shut-down signals

Safety and maintenance:        Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak

            handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.

GLP features:                          Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy using Raman band (H 2 O).

Housing:                                  All materials recyclable

Environment:                                      0 to 40 °C constant temperature at <95%, humidity (non-condensing)

Dimensions (h x w x d):          140 mm x 345 mm x 435 mm, (5.5 x 13.5 x 17 inches)

Weight:                                    11.5 kg (25.5 Ibs)

* Reference conditions: standard cell 8µl, response time 4s, 2.1 x 100 mm ODS column, 0,4 ml/min flow rate.