Agilent 8453
| Objektnummer | B00018843 |
|---|---|
| Seriennummer | 018843 |
| Nome oggetto | Agilent 8453 |
| Stato | Archived Product |
Gruppo prodotti: Fotometri / Spettrofotometri
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Hersteller : Agilent
Modell : 8453
Die folgenden Abbildungen und Beschreibungen beziehen sich auf das Gerätemodell und stammen aus Prospekten. Sie stellen nicht den Lieferumfang dar. Den genauen Lieferumfang entnehmen Sie bitte dem Angebotstext.
Spezifikationen
Optische Leistung
Wellenlängenbereich 190–1100 nm
Spaltbreite 1 nm
EP-Auflösungstest > 1,6 Toluol in Hexan, Verhältnis abs. bei 269 nm / 266 nm
Streulicht <0,03% bei 340 nm (NaNO 2, ASTM)
<0,05% bei 220 nm (NaI, ASTM)
<1% bei 198 nm (KCl, EP)
Wellenlängengenauigkeit <± 0,5 nm 0,5-Sekunden-Scan (NIST 2034)
<± 0,2 nm bei 486,0 und 656,1 nm
Wellenlängenreproduzierbarkeit <± 0,02 nm bei zehn aufeinanderfolgenden Scans (NIST 2034)
Photometrische Genauigkeit <± 0,005 A bei 440,0, 465,0, 546,1, 590,0 und 635,0 nm, 1 A (NIST 930e)
<± 0,01 A bei 235, 257, 313, 350, 430 nm (Kaliumdichromat, EP-Methode)
Photometrisches Rauschen <0,0002 A 60 0,5 Sekunden Abtastung bei 0 A, 500 nm, Effektivwert
Photometrische Stabilität <0,001 A / h bei 0 A, 340 nm, nach einstündigem Aufwärmen, gemessen über 1 Stunde, alle 5 Sekunden, konstante Umgebungstemperatur.
Grundlinienebenheit <0,001 Ein 0,5-Sekunden-Blindwert, 0,5-Sekunden-Scan, Effektivwert
Die typische Scanzeit beträgt 1,5 Sekunden
Kürzeste Scan-Zeit 0,1 Sekunden voller Bereich
Zeit bis zum nächsten Scan 0,1 Sekunden voller Bereich, 0,1 Sekunden Scan, bis zu 150 aufeinanderfolgende Scans
Abmessungen
Höhe x Breite x Tiefe 185 x 344 x 560 mm (7,3 x 13,5 x 22,0 Zoll)
Gewicht 16,5 kg
Leistungsbedarf
Netzspannung 90–264 V AC
Netzfrequenz 47–63 Hz
Leistungsaufnahme 70 VA typisch
Umweltbedingungen
Betriebstemperatur 0–50 ° C
Betriebstemperatur -40–70 ° C (-4–158 ° F)
Luftfeuchtigkeit <95% bei 25–40 ° C