Soldé

Agilent 5973 N

Seriennummer: 014039
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00014039
Seriennummer 014039
Nome oggetto Agilent 5973 N
Stato Archived Product

Gruppo prodotti: GC / MS

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Agilent

Modell:            5973 N

Kommentar:    Dokumente engl. (nur für IDNR.10325)

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.

Agilent 5973N

The 5973NMSD is a stand-alone capillary GC detector

The 5973N Mass Selective Detector (MSD) is designed for use with the 6890 Plus Series Gas Chromatograph.

The MSD features:

•     Control panel for locally monitoring and operating the MSD

•     One of three different high vacuum pumps

•     Rotary vane foreline pump

•     Independently heated electron-ionization ion source

•     Independently heated hyperbolic quadrupole mass filter

•     High-energy dynode (HED) electron multiplier detector

•     Independently heated GC/MSD interface

•     Chemical ionization (EI/PCI or EI/PCl/NCI) models available

Physical description

The 5973N MSD is a rectangular box, approximately 42 cm high, 26 cm wide, 65 cm deep. The weight is 25 kg for the diffusion pump mainframe, 26 kg for the standard turbo pump mainframe and 29 kg for the performance turbo pump mainframe. The attached rough pump weighs an additional 11 kg.

The basic components of the instrument are: the frame/cover assemblies, the control panel, the vacuum system, the GC interface, the electronics, and the analyzer.

The control panel allows local monitoring and operation of the MSD

The control panel acts as a local user interface to the MSD. You can perform some basic tasks such as running a tune, a method, or a sequence; and monitor MSD status from the control panel.


Agilent 7694

Major Units

Description

1           Loader Unit

2           Tray Unit

3           Control Unit

4           Sampler Unit

5           Oven Unit


Hewlett Packard 6890

At every step in the growth of gas chromatography as an essential analytical tool for research, quality control, and environmental testing, Hewlett­Packard has led the way with systems that have taken chro­matography to the peak of performance.

Now the HP 6890 Series GC system takes you to the next level of Gc performance. It is a complete chromatography sys­tem, from sample preparation through data management. The system features the HP 6890 Series GC, a dual channel gas chromatograph, that is available with electronic pneumatics control (EPC) for all pneumatic parameters, or it is available with manual control. The system can be easily con­figured for automated operation and for a broad spectrum of industries and applications.

The HP 6890 Series GC system will be the platform for GC growth into the 21st century.

It has been developed with extensive input from chromatographers to let you easily and routinely meet the ever more challenging demands of business with improvements in

• Performance

• Productivity

• Usability

• Dependability

• GLP Compliance

• Value

See how the HP 6890 Series GC system can help you grow to meet the business challenges of the nineties-and beyond.


Hewlett Packard G1576A

__________________________________________________________________________

Hewlett Packard 7683

Der HP 7683 Automatische Probengeber besteht aus dem HP G2612A ALS Interface Board, dem HP G2613A Injektormodul, optional dem HP G2614A Probenteller sowie einer optionalen HP G1926A Barcode-Leseeinheit für den Probenteller. Der Probenteller ist auf dem HP 6890 Plus Gaschromatograph (GC) installiert.

Der Probengeber entnimmt aus einem Probenfläschchen mit 2 ml oder 100 µL Inhalt eine Probe und injiziert sie zu einer vorwählbaren Zeit in den Einlaß des HP 6890 Gaschromatographen. Nur mit der Ladeeinheit können Sie bis zu 8 Probenflaschen mit der Ladeeinheit verwenden, mit dem optionalen HP G2614A Probenteller und der Standardladeeinheit bis zu 100 Probenflaschen.

Zusätzlich hat der Probengeber folgende Möglichkeiten:

•     Pre- und Postinjektionsspülungen mit Lösungsmittel

•     Preinjektionsspülungen mit Probe

•     Probenförderung

•     Aktivierung verlängerter Ansaugzeiten, z. B. für hochviskose Proben

•     Injektion verschiedener Probenmengen aus unterschiedlichen Probenfläschchen

•     Pausieren einer Sequenz zum Vermessen von Proben mit Priorität und Wiederaufnahme der Sequenz

•     Cool-On-column Injektionen auf 250 µm-, 320 µm- und 530 µm-Säulen

Kenndaten des automatischen Flüssigprobengebers

Parameter                                                Wählbarer Bereich

Spritzenvolumen                                        5, 10, 25, 50, oder 100 µL

Anzahl Probenfläschchen                          Bis zu 8 ohne und bis zu 100 mit Probenteller

Anzahl Injektionen pro                                1 bis 99

Probenfläschchen

Injektionsvolumen          Minimum               0,1µL (mit 5µL Spritze)

                                      Maximal                50.0µL      (100µL Spritze)

Injektionsgeschwindigkeit (µl/sec)             Langsam         Schnell

5 µL Spritze                                                2,5                    50

10 µL Spritze                                              5                       100

25 µL Spritze                                              12,5                  250

50 µL Spritze                                              25                     500

100 µL Spritze                                            50                     1000

Gesamtzeit der Injektion                            0.1 s (Standard)

(Näherungsweise)                                      4 s (Cool on-column)

Injektionstiefe                                              -2 bis +30 mm über Standard

Verzögerung für hochviskose Proben       0 bis 7 Sekunden

Anzahl der Prewash-Operationen vor       0 bis 15

Injektion

Anzahl von Probenförderungen                 0 bis 15

Anzahl Prewash-Operationen mit              0 bis 15 (pro Flasche)

Lösungmittel

Anzahl Postwash-Operationen mit            0 bis 15 (pro Flasche)

Lösungsmittel

Modus Mehrfachinjektion (nur mit PTV-Einlaß)