Agilent 3D-Capill.Elek

Seriennummer: 008996
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Descrizione:
Agilent 3D elettroforesi capillare tipo G100A. Con DAD. Software ChemStation. Stampanti laser. Anno: 1997. Prezzo originale: 48 570, - Euro.
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00008996
Seriennummer 008996
Nome oggetto Agilent 3D-Capill.Elek
Stato Archived Product

Gruppo prodotti: Elettroforesi Capillare

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Agilent

Modell:            3D-Capill.Elek

Kommentar:   Dokumente dt./engl.

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

Hersteller:                  Hewlett Packard

Typ:                           3D-Capillary Electrophoresis Instrument G1600A

Ausstattung:              HP 3D Kapillarelektrophorese-System:

                                 3D CE-Gerät mit DAD

                                 3D-CE Chemstation-Software

Zubehör:                    HP Vectra XM4 5/150

Überwachung:           gemäß QM-VA 1110-03 Abschnitt 5.2.2., bei jeder Meßreihe

Wartung:                   Reinigung der Elektroden und Prepuncher einmal die Woche.

                                 Austausch der Luftfilter bei Bedarf ( ca. alle 2 Monate)

Reinigung:                 bei Bedarf mit handelsüblichen Reinigern

HP G1602A

HP 3D Kapillarelektrophorese-System einschl. HP 3D CE-Gerät, HP 3D-CE Chem­station-Software, HP Vectra XM4 5/150 HP LaserJet 5- Drucker und Win 95

HP G1314A

HP 1100 Variabler Wellenlängendetektor Mit variablem Wellenlängendetektor mit Deuteriumlampe und CAN-Kabel, Ohne Flußzelle

Standardflußzelle

Flußzelle aus Edelstahl mit 10 mm optischer Weglänge und 14 Mikroliter Volumen. Druckfest

bis zu 40 bar

Specifications

Dimensions                    Width                   42.5 cm, (16.8 in)

                                       Height                  57.5 cm, (22.7 in)

                                       Depth                   52 cm, (20.5 in)

                                       Weight                 52 kg, (115 Ib)

Environment                   Temperature:       5—40 °C

                                       Humidity:              up to 80 %, at 30 °C (non-condensing)

Power requirements       Line voltage:        100/120/220/240 VAC ; +5 %, -10 %, 650 VA

                                       Line frequency:   50 (48—55) Hz; 60 (57—66 ) Hz

Pressure system            Programmable with 0—50 mbar bidirectional

Flushing with 1 bar or with high pressure 2—12 bar bidirectional Vial pressurization with high pressure 2—12 bar

Safety features               Current leak detection; Low current limit

Safety sensors at door and cover disabling high voltage Diagnostic functions

Electrophoresis power   Voltage range: setable 0 to ± 30 kV supply

                                       Current:        setable 0—300 µA

                                       Power:          setable 0—6 W

Operation under constant voltage, current or power Programmable polarity switch

Injection modes              Seif correcting injection system with injection from both ends

                                       Programmable range:             up to 10,000 seconds

                                       Pressure:                                 0—50 mbar

                                       Electrokinetic:                          0—30 kV

Autosampler/                  48-position carousel. All vials are randomly accessible from

fraction collector             cathode and anode end of capillary. Temperature control with external waterbath with vial temperature from 10—40 °C (non-condensing conditions)

Replenishment               Satellite Station for refilling anode and cathode buffer vials with fresh buffer for automatic continuous operation and buffer selectable buffer levelling

Vials                                100 µl sample vials, 1 ml or 2 ml buffer vials (polypropylene or glass) with resealing snap caps

Capillary cassette           Forced-air temperature-controlled with Peltier element

                                       Temperature range:                      10 °C below ambient to 60 °C (± 0.1 °C) with a min. of 4 °C

                                       Minimum total capillary length:      33 cm

                                       Capillary compatibility                   365 µm o.d.

Detector                          Real time UV-Visible diode-array detector (190—600 nm)

                                       Wavelength accuracy:             1 nm

                                       Response time:                       0.1 to 10 s (8 choices)

                                       Light source:                            prealigned deuterium lamp

                                       Signals:                                    up to five signals simultaneously, full spectral acquisition with Agilent ChemStation

Raw data channels        Detector signals, voltage, current, power, capillary temperature and pressure.

System control               Operating with graphical user interface under Microsoft° Windows 95 and Windows NT

                                       Time programmable parameters:

voltage, current, power, polarity pressure, inlet and outlet vial capillary temperature, pre and post-run conditioning with pressure and/or voltage, replenishment, fraction collection

CE specific software      Mobility report, time corrected areas, pl calibration and bio polmer

                                       size calibration

CE — for highest confidence in your results

Typically, there are five steps required for full instrument, method and data validation. Agilent Technologies offers software tools and kits to facilitate and automate there steps for the Agilent CE system.

Step1: Qualify your vendor and your vendor's design

Ensured with Agilent's reputation and documentation of successful development validation.

Step 2: Qualify the instrument in your laboratory before beginning operation

Follow the appropriate test procedures and certification for Installation Qualifica­tion (IQ) and Operation Qualification/ Performance Verification (OQ/PV). Agilent offers a kitwhich provides instructions, methods and materials for performing OQ/PV for the Agilent CE system.

Step 3: Validate your analytical method

The Agilent ChemStation includes system suitability software for automated method validation.

Step 4: Qualify system performance during routine operation

Agilent's software features automated daily system suitability testing, with an optional database with online quality control charts for documenting perfor­mance parameters.

Step 5: Ensure data security, integrity and traceability

The software has a password-protected user access. lt saves instrument condi­tions and logbooks together with raw data in checksum-protected binary fites.