Agilent 3D-Capill.Elek
| Objektnummer | B00008996 |
|---|---|
| Seriennummer | 008996 |
| Nome oggetto | Agilent 3D-Capill.Elek |
| Stato | Archived Product |
Gruppo prodotti: Elettroforesi Capillare
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Kommentar: Dokumente dt./engl.
Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.
Sie geben nicht den Lieferumfang des Systems wieder.
Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.
Hersteller: Hewlett Packard
Typ: 3D-Capillary Electrophoresis Instrument G1600A
Ausstattung: HP 3D Kapillarelektrophorese-System:
3D CE-Gerät mit DAD
3D-CE Chemstation-Software
Zubehör: HP Vectra XM4 5/150
Überwachung: gemäß QM-VA 1110-03 Abschnitt 5.2.2., bei jeder Meßreihe
Wartung: Reinigung der Elektroden und Prepuncher einmal die Woche.
Austausch der Luftfilter bei Bedarf ( ca. alle 2 Monate)
Reinigung: bei Bedarf mit handelsüblichen Reinigern
HP G1602A
HP 3D Kapillarelektrophorese-System einschl. HP 3D CE-Gerät, HP 3D-CE Chemstation-Software, HP Vectra XM4 5/150 HP LaserJet 5- Drucker und Win 95
HP G1314A
HP 1100 Variabler Wellenlängendetektor Mit variablem Wellenlängendetektor mit Deuteriumlampe und CAN-Kabel, Ohne Flußzelle
Standardflußzelle
Flußzelle aus Edelstahl mit 10 mm optischer Weglänge und 14 Mikroliter Volumen. Druckfest
bis zu 40 bar
Specifications
Dimensions Width 42.5 cm, (16.8 in)
Height 57.5 cm, (22.7 in)
Depth 52 cm, (20.5 in)
Weight 52 kg, (115 Ib)
Environment Temperature: 540 °C
Humidity: up to 80 %, at 30 °C (non-condensing)
Power requirements Line voltage: 100/120/220/240 VAC ; +5 %, -10 %, 650 VA
Line frequency: 50 (4855) Hz; 60 (5766 ) Hz
Pressure system Programmable with 050 mbar bidirectional
Flushing with 1 bar or with high pressure 212 bar bidirectional Vial pressurization with high pressure 212 bar
Safety features Current leak detection; Low current limit
Safety sensors at door and cover disabling high voltage Diagnostic functions
Electrophoresis power Voltage range: setable 0 to ± 30 kV supply
Current: setable 0300 µA
Power: setable 06 W
Operation under constant voltage, current or power Programmable polarity switch
Injection modes Seif correcting injection system with injection from both ends
Programmable range: up to 10,000 seconds
Pressure: 050 mbar
Electrokinetic: 030 kV
Autosampler/ 48-position carousel. All vials are randomly accessible from
fraction collector cathode and anode end of capillary. Temperature control with external waterbath with vial temperature from 1040 °C (non-condensing conditions)
Replenishment Satellite Station for refilling anode and cathode buffer vials with fresh buffer for automatic continuous operation and buffer selectable buffer levelling
Vials 100 µl sample vials, 1 ml or 2 ml buffer vials (polypropylene or glass) with resealing snap caps
Capillary cassette Forced-air temperature-controlled with Peltier element
Temperature range: 10 °C below ambient to 60 °C (± 0.1 °C) with a min. of 4 °C
Minimum total capillary length: 33 cm
Capillary compatibility 365 µm o.d.
Detector Real time UV-Visible diode-array detector (190600 nm)
Wavelength accuracy: 1 nm
Response time: 0.1 to 10 s (8 choices)
Light source: prealigned deuterium lamp
Signals: up to five signals simultaneously, full spectral acquisition with Agilent ChemStation
Raw data channels Detector signals, voltage, current, power, capillary temperature and pressure.
System control Operating with graphical user interface under Microsoft° Windows 95 and Windows NT
Time programmable parameters:
voltage, current, power, polarity pressure, inlet and outlet vial capillary temperature, pre and post-run conditioning with pressure and/or voltage, replenishment, fraction collection
CE specific software Mobility report, time corrected areas, pl calibration and bio polmer
size calibration
CE for highest confidence in your results
Typically, there are five steps required for full instrument, method and data validation. Agilent Technologies offers software tools and kits to facilitate and automate there steps for the Agilent CE system.
Step1: Qualify your vendor and your vendor's design
Ensured with Agilent's reputation and documentation of successful development validation.
Step 2: Qualify the instrument in your laboratory before beginning operation
Follow the appropriate test procedures and certification for Installation Qualification (IQ) and Operation Qualification/ Performance Verification (OQ/PV). Agilent offers a kitwhich provides instructions, methods and materials for performing OQ/PV for the Agilent CE system.
Step 3: Validate your analytical method
The Agilent ChemStation includes system suitability software for automated method validation.
Step 4: Qualify system performance during routine operation
Agilent's software features automated daily system suitability testing, with an optional database with online quality control charts for documenting performance parameters.
Step 5: Ensure data security, integrity and traceability
The software has a password-protected user access. lt saves instrument conditions and logbooks together with raw data in checksum-protected binary fites.