Descrizione:
Adrona Sistema di trattamento dell'acqua Crystal EX HPLC. Modello EX-1101. Produzione di acqua ultrapura per analisi IC, ICP, HPLC, GC e TOC. Acqua di grado 1 (18.2 Mohm x cm). Grado 2 (> 10 Mohm x cm). Contenuto TOC: <2 ppb. Portata nominale: 4 L / min (Grado 2) o 2 L / min (Grado 1). Dimensioni: 55x40x35 cm. Con serbatoio di stoccaggio da 30 litri. Pressione dell'acqua di alimentazione 0,5-5 bar. La conduttività dell'acqua di alimentazione deve essere <900 µS / cm. Nuovo. Garanzia del produttore
Add to Offer list
Maggiori Informazioni
Objektnummer B00021935
Seriennummer 21935
Nome oggetto Adrona Crystal EX HPLC
Stato Neugerät
Fabbricante Adrona
Spedizione 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

manufacturer:       Adrona

model:                   Crystal E HPLC

annotation:           Dokumente engl .

 

 

 

 

 

The Crystal E ultrapure systems are economy class, multi-purpose, water purification systems.

 

 

All Crystal E systems produce two types of water: Ultrapure (ISO 3696 Grade 1) and Pure (ISO 3696 Grade 2). Ultrapure water produced by the Crystal E systems has resistivity 18.2 MegaOhm *cm (conductivity 0.055 μ S/cm). This exceeds requirements of all the relevant standards (ISO 3696 Grade 1, ASTM Type I, CLSI Type I). Purified water is collected in a storage tank. The recirculation system ensures a consistent quality of water, and a low level of organic carbon content (TOC). TOC is <2ppb for “HPLC” and “Bio” configurations; and 5-10 ppb for the “Trace” configuration.

 

The dispensing rate of high-quality, Ultrapure water is 2 L/min.

 

Pure water produced by Crystal E systems can be used for labware washing, wet chemistry methods, flame spectrophotometers, etc.. Pure water is dispensed directly from the storage tank. The dispensing flow rate of Pure water is 4 L/min.

 

All systems have a graphic LCD display that provides a clear waterquality readout. The display also provides information about the system status. This includes current resistivity and remaining prefilter service life. The smart deionization (DI) module performance monitoring system provides a reduction in running costs. All cartridge and filter replacement can be done by the operator and no tools are required. The Crystal E systems include important safety functions, such as:

§         tank filling control

§         tap water pressure control

§         protection from a tank sensor failure

 

Running costs can be decreased even more by installing an 8L deionization module option (P/N 10101).

 

Crystal E systems include:

§         Boost pump

§         Pre-filter

§         RO module

§         Deionization module

§         Polishing module

§         25L storage tank with integrated Grade 2 dispensing pump

§         Recirculation system

§         Point-of-use Final Filter:

§         0.22 μ m microfilter for Crystal E Trace and HPLC systems

§         ultrafilter for Crystal E Bio systems

§         Photo-oxidation module for reduction of organics (for HPLC and Bio configurations)

§         UV sterilization module (for the Bio configuration)

 

 

Crystal E HPLC System (P/N CE-1101) produces water with very low organic carbon content

(TOC) to comply with the requirements of liquid chromatography methods. Crystal E HPLC water can also be used for some microbiological and molecular biology applications.

 

 

Purified water specifications Crystal E HPLC

 

Grade 2 water resistivity

>10 M Ω x cm

 

Grade 2 water conductivity

<0.1 μ S/cm

 

Grade 1 water resistivity

18.2 M Ω x cm

 

Grade 1 water conductivity

0.055 μ S/cm

 

TOC

<2 ppb

 

RNase

N/A

 

DNase

N/A

 

Bacteria

< 1 cfu / mL

 

Endotoxins

<0.15 EU/ mL

 

Particles > 0.22 μ m

<1 per mL

 

Nominal flow, pure water (to storage tank)

10 L/h

 

Nominal dispense flow, ultrapure water

2 L/min

 

Nominal dispense flow, pure water

4 L/min

 

Deionization module life (standard module)

1 m³

 

Deionization module life (high capacity module)

3 m³

 

Recovery

>30 %

 

Dimensions ( WxDxH ), cm

40x35x55

 

Storage tank

25 L

 

Tank dimensions ( WxDxH ), cm

30x25x50

 

Feed water pressure

0.5 – 5 bar

 

Feed water conductivity

< 900 μ S/cm

 