Abimed TN 05
| Objektnummer | B00015100 |
|---|---|
| Seriennummer | 015100 |
| Nome oggetto | Abimed TN 05 |
| Stato | Archived Product |
Gruppo prodotti: Analizzatori per N e NOX
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Abimed
Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.
Sie geben nicht den Lieferumfang des Systems wieder.
Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

Das System TN-05 dient zur Bestimmung von Stickstoff in organischen und in anorganischen Verbindungen.
Stickstoffgehalte im ppb und ppm Bereich können in Proben wie Wasser und Ölprodukten präzise und genau mit dem Gesamtstickstofanalysator TN-05 gemessen werden.
Standardspezifikationen
Model Gesamtstickstoffanalysator TN-05
Haupteinheiten Reaktor-Einheit, Detektor-Einheit, Datenverarbeitungseinheit
Meßbare Substanzen Gesamtstickstoffgehalt von Wasser oder Organischen Lösungen
Meßmethoden Standard Modus
Constant Rate Injektions Modus
Automatischer Probenaufgaben Modus ASI
Automatische Probenaufgabe +
Automatischer Probengeber
Analysen-Methode Oxidative Pyrolyse und Chemilumineszenz
Meßbereich 0,01 bis - 500 ppm Stickstoff
Reproduzierbarkeit
|
Probe |
Volumen |
Variationskoeffizient |
|
Ammonium Sulfat Lösung N=10 ppm |
20 µl |
< 3 % |
|
Pyridin inToluol Lösung N=10 ppm |
20 µl |
< 5 % |
Probenvolumen 5 - 50 µl
Analysendauer 1 - 5 min
Ofentemperatur bis 950 °C
Signalausgang RS-232C, Analog 0 - 1 V DC F.S.
Erforderliche Gase Sauerstoffgas 4 kg/cm 2 (Reinheit mindestnes 99 7 %)
Argongas 4 kg/cm 2 (Reinheit mindestens 99,98 %)
(Argongas wird nur benutzt, wenn organische Proben gemessen werden.)
Stromversorgung 220 V Wechselstrom, 2,3 kVA, 50/60 Hz
Abmessung und Gewicht Reaktor-Einheit
400 x 400 x 500 mm BTH, 32 kg
Detektor-Einheit
400 x 400 x 225 mm BTH, 20 kg
Datenverarbeitungseinheit
400 x 350 x 170 mm BTH, 10 kg
Automatischer Probeninjektor Model TN-05 ASI
Der automatische Probeninjektor Model TN-05 ABI wird benutzt, um wässrige Proben automatisch in den Gesamtstickstoffanalynator TN-05 zu injizieren.
Spezifikationen
Analysierbare Proben: Wässrige Proben ohne suspendierte Feststoffe
Injektionsvolumen: 25 µl
Benötigte Gase: Sauerstoff 2 kg/cm 2 G
(Reinheit mindestens 99,7 %)
Strombedarf: 220 V, 50/60 Hz, 35 VA
Abmessungen: ca. 345 x 300 x 245 BTH