Abbott Cell-Dyn 1800

Seriennummer: 017207
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Descrizione:
Abbott hematology Analyser Cell-Dyn 1800. With scanner and OKI printer B4250. YoC 2007
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00017207
Seriennummer 017207
Nome oggetto Abbott Cell-Dyn 1800
Stato Archived Product

Gruppo prodotti: Ematologia

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                   Abbott

Modell:                Cell-Dyn

Kommentar:        Dokumente deut.

 

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

 

 

Das CELL-DYN 1800 System ist ein automatisches Multiparameter-Hämatologie-Analysensystem für die In-vitro-Diagnostik im klinischen Labor.

 

Der CELL-DYN 1800 wurde entwickelt, um den Bedürfnissen der Hämatologie-Diagnostik im wechselnden Laborumfeld von heute gerecht zu werden. Einfachste Handhabung, geringer Wartungsaufwand, hohe Zuverlässigkeit und geringer Probenverbrauch sind Eigenschaften, die von einem modernen Hämatologie-System erwartet werden. Um den wachsenden Ansprüchen des heutigen Labors zu genügen, sind ein schneller Zugriff auf Ergebnisse, eine umfangreiche Datenverwaltung und eine vereinfachte Datenauswertung notwendig. Alle diese Vorzüge bietet der CELL-DYN 1800 den Hämatologie-Labors, die modernste Technologie einsetzen möchten.

 

Der CELL-DYN 1800 liefert schnell genaue Befunde und Differentialblutbilder und zeichnet sich durch sein umfangreiches Datenmanagement in einem kompakten, leicht zu bedienenden System aus.

 

*                    Automatisches 18-Parameter-System

*                    Dreiteiliges Leukozyten-Differentialblutbild

*                    Graphische Darstellung mit drei Histogrammen

*                    30 Mikroliter Probenverbrauch

*                    Umfassendes Blutbild in 60 Sekunden

*                    Speicher für 5'000 Befunde mit Histogrammen

*                     

Abmessungen

Höhe           45 cm

Breite          66 cm

Tiefe           53 cm

Gewicht      55 kg

 

Spezifikationen der Messung

Messkanal

Das CELL-DYN 1800 hat zwei Widerstandsmesskanäle, einen für die WBC­Widerstandsmessung und einen für RBC und PLT.

WBC und Differenzierung

•            Methode:          Elektrische Widerstandsmessung mit volu­metrischer Messung

•            Größe der Messöffnung          100 µm im Durchmesser x 60 µm in in der Länge

•            Verdünnung:    Ein Teil Vollblut in 284 Teilen Verdünnungs­mittel und Lysereagenz

RBC und PLT

•            Methode:          Elektrische Widerstandsmessung mit volu­metrischer Messung

•            Größe der Messöffnung          60 µm im Durchmesser x 70 mm in der Länge

•            Verdünnung:    Ein Teil Vollblut in 12.801 Teilen Verdün­nungsmittel

HGB

•            Methode:          Modifiziertes Cyanmethämoglobin mit auto­matischem Leerwert

•            Lichtquelle:      LED

•            Wellenlänge:    540 nm

•            Verdünnung:    Ein Teil Vollblut in 284 Teilen Verdünnungs­mittel und Lysereagenz

 