PCR

Appl.Biosystems 7300

6.313,00 €
Excl. 19% VAT , excl. Shipping Cost
7.512,47 € incl. Vat
Seriennummer: 38379
Stato: Apparecchi in stockL'articolo è disponibile. I nostri tecnici ispezioneranno l'articolo prima della consegna. Riceverai articoli perfettamente funzionanti.?
Spedizione: 10-14 working daysiFor incoming orders until 12:00 (German local time). If customs handling is required, shipment will be delayed.
Descrizione:
Applied Biosystems RealTime PCR System 7300.
Per micropiastre da 96 pozzetti.
PC portatile Dell, WinXP SP2.
Software di rilevamento della sequenza 1.4.
Frequenza di campionamento del campione: +/- 1,1°C/sec.
Intervallo di temperatura: 4-100°C.
Durata quantitativa della PCR: < 1h 50 min.
Interfaccia USB di tipo B
230 V. 50/60 Hz. 725 W.
Add to Offer list
Maggiori Informazioni
Objektnummer B00038379
Seriennummer 38379
Nome oggetto Appl.Biosystems 7300
Stato Apparecchi in stock L'articolo è disponibile. I nostri tecnici ispezioneranno l'articolo prima della consegna. Riceverai articoli perfettamente funzionanti.
Fabbricante Appl.Biosystems
Spedizione 10-14 working days

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

 

manufacturer:     Applied Biosystems

model:                  7300

 

 

The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.

 

Instrument specifications

 

Thermal cycling system                     Peltier-based, 96-well block

Sample Ramp Rate                           +/-1.1°C/sec

Peak Block Ramp Rate                     1.6°C/sec

Temperature Range                          4°C – 100°C

Temperature Accuracy                      ±0.25°C of setpoint/display temperature measured at 3 minutes after clock start

Temperature Uniformity                     ±0.50°C, 30 seconds after clock start

Optical system                                   Single excitation, four emission filters, and CCD camera

Calibrated Dyes at Installation           SYBR® Green I, FAMTM, VIC®, JOETM, NEDTM, TAMRATM, ROXTM

Passive Reference Dyes                   ROXTM or any calibrated dye.

Data Collection                                  Data collected in all 4 filters for all wells regardless of plate setup. Plate setup may be altered after run completes.

Quantitative PCR run time                 < 1 hour 50 minutes

Supported Volumes                           20 – 100 μL

Supported Consumables                   • Standard optical 96-well plates • 8-strip 0.2mL tubes • 0.2mL tubes • Optical adhesive covers • Optical flat caps

Width x Depth x Height                      System 34x45x49 cm

                                                           Tower 18x45x42 cm

                                                            Notebook 32x26x3 cm

Weight                                                 System 29 kg ;   Tower 32 kg;   Notebook 2,1 kg.

Gruppo prodotti: PCR

Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Labprocure