I JavaScript sembrano essere disabilitati nel tuo browser. Per una migliore esperienza sul nostro sito, assicurati di attivare i javascript nel tuo browser.
Usually, laboratory and analysis devices are very exigent system with a very own specifications and requirements. Therefore, the startup of a laboratory device often rises the question how to assemble, adjust and to launch it.
We would be pleased to take over the professional installation of your laboratory devices!Please contact us.
Benefit from the installation by us in more than one way:
All guarantee services for you
optional guarantee services bring even more safety
optional installation of equipment for immediate and safe use of equipment
We shall be glad to answer your questions regarding this device
Attractive rental and leasing offers conserve your budget
Use our free call-back-function
Se si acquista questo articolo usato anziché nuovo, si risparmia tanta CO2 quanta se ne percorre 290 km con un'auto a benzina.
Garanzia:Tutti gli strumenti utilizzati da Labexchange sono soggetti a verifiche ed ispezioni prima della consegna che avverrà solo nel caso essi risultino perfettamente funzionanti. La verifica e la funzionalità sono documentate da un rapporto di una società di servizio indipendente. La Labexchange Fullguarantee è di 60 giorni. (Valido per i paesi all'interno dell'UE e CH) Certificato di funzionamento:La verifica della funzionalità dei nostri strumenti è documentata oltre che dal rapporto di servizio anche da un certificato di funzionamento.Garanzia:Il periodo di garanzia dei nostri strumenti è di 24 mesi dalla data di consegna.
On demand, we verify the option of an extension of warranty for your device. If possible, the period of warranty is 6 months for 10 % extra charge and 1 year for 20 % extra charge on the list price. (Valid for DE, AT, CH, FR, NL, BE, LU, GB and IR)
Play it safe! We are pleased to offer you the installation of your laboratory equipment. Our qualified technicians install the device on your desired date in the laboratory, so that you can work quickly and safely with your new laboratory equipment.
The installation of the equipment by Labexchange brings further advantages. You thereby obtain a guarantee extension to 3 months and you have also the right to the Labexchange Repurchase Guarantee.
You receive sensible laboratory equipment and analytical systems as well as much of the available laboratory hoods, already incl. installation.
* Campi obbligatori
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country
Possible payment methods
Comment
DE, AT, CH
Payment by invoice, payment in advance
Payment by invoice is only possible for corporate clients.
NL, BE, LU
Payment by invoice is only possible for corporate clients
Other countries
Payment in advance
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
All articles are used articles, except an article is listed especially as a new device.
Status
Condition
Immediately available
Used
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.
Published
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.
New device
new
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.
Firma: Gilson
Modell: 155
Kommentar: Dokumente engl.
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
Gilson 155 UV/UVIS Detector
The Gilson 155 and 156 UVNIS Detectors are microprocessor-controlled absorbance detectors that provide dual wavelength detection. Both detector models are compatible components of a Gilson modular HPLC system. And, the 155 Detector with its front panel control is also compatible with other commercially available HPLC systems.
The 155 Detector can be controlled via its front panel or via TRILUTIIoN'"" LC Software. The 156 Detector must be controlled via TRILuTION LC since it does not have an integral front panel display. For information an how to control the 156 Detector, refer to the TRILuTioNTM" LC Software User's Guide.
Gilson's optical design lets you monitor absorbance at any wavelength from 190 to 700 nm.
The detector has a sensitivity range of 0.001 to 2.0 AUFS (Absorbance Units, Full Scale).
The 155 Detector software is self-guiding.
All parameters, values and commands appear an the four-line display.
All of your options are displayed above the six soft keys. Press a soft key to choose and carry out a command. Numeric entries are made using the keypad.
You can choose from the following modes to specify detection conditions and basic operating parameters:
single wavelength
dual wavelength
scan wavelength
setup
status
fite
Suppresses up to 1.0 AU with 5 mm flow cell installed
Event and autozero inputs: remote contact closure can be activated by other Instruments or the Computer
Three channels output data to a recorder.
Four-line display shows modes, parameters, commands and data (155 only)
After one hour at constant temperature: 3.0 x 10 -4 AU/hour
4.0 x 10 -4 AU for flow step of 2.0 mL/min to 0.5 mL/min with methanol
LAMP ON/OFF hard key, LED indicator Iights for POWER, UV, VIS, REMOTE, and ERROR (155 and 156)
Six soff keys, HELP, ESC and CLEAR hard keys, arrow keys, numeric hard keys, and ENTER hard key (155 only)
One hour maximum time
UV Iamp: Deuterium, warranted for 750 hours or 180 days shelf-life Visible Iamp: Tungsten/halogen Iamp, warranted for 500 hours
1%, when value is within sensitivity range of 0.001 to 2.0 AU
The following quartz flow cells are available:
Pressure
Flow cell
Pathlength
Volume
psi
bar
MPa
Analytical
5 mm
12 µL
500
34.5
3.45
Preparative
0.05 mm
0.16 µL
0.2 mm
0.7 µL
Capillary
8 mm
35 nL
3000
200
20
Microbore
2 mm
1.6 µL
SFC*
0.5 mm
2.0 µL
10000
689.7
68.97
10µL
*Stainless steel
Meets applicable Safety and EMC certification standards; UL and CE certified.
Dual beam, steppermotor-driven
Range: 190 to 700 nm
Spectral bandwidth: 9 nm
Setting accuracy: ±2 nm
Setting precision: ±0.2 nm
220 nm, short term, peak to peak; 2.0 x 10 -5 AU/cm
254 nm, short term, peak to peak; 2.5 x 10 -5 AU/cm
350 nm, short term, peak to peak; 10.0 x 10 -5 AU/cm
415 nm, short term, peak to peak; 8.0 x 10 -5 AU/cm
520 nm, short term, peak to peak; 6.0 x 10 -5 AU/cm
650 nm, short term, peak to peak; 4.0 x 10 -5 AU/cm
Single wavelength, dual wavelength, scan wavelength, status, setup, and fite
0.0 or 4.0 to 99.0 seconds
26.5 x 43.5 x 15.6 cm (10.4 x 17.1 x 6.2 in) requirement
Frequency: 50 to 60 Hz
Voltage: 90-240V
Current rating: 1.5A for 90-120V or 1.0A for 220-240V
Online switching regulation of line input from 80 to 260V AC
0.001 to 2.0 AU. Sensitivity is adjustable in increments of 0.001 AU.
You can issue commands via the GSIOC or RS-232
You can use the GSIOC or RS-232 to do the following:
Select all detection parameters
Program parameter changes during run to optimize detection
Send digital detector output
Methanol versus cyclohexane at 270 nm: 5.0 x 10 -3 AU
3.0 x 10 -4 /°C for temperature change from 21 ° to 24°C
8.6 kg (19 lbs.)
Il tuo Labexchange-Team sarà lieto di aiutarvi:
Christian Schmid Laboratory and analysis, Laboratory equipment, Life science
Hubert Sauter Spectroscopy, Chromatography