Statut: En stockL'article est en notre stock, mais doit être vérifié avant la livraison par nos techniciens Vous recevez des articles entièrement fonctionnels.?L'article est en notre stock, mais doit être vérifié avant la livraison par nos techniciens Vous recevez des articles entièrement fonctionnels. Immediately available"
Envoi: 10-14 jours ouvrablesiFor incoming orders until 12:00 (German local time). If customs handling is required, shipment will be delayed.
Description:
Tecator Système Soxhlet HT2. 2-flamme. Avec unité d éxtraction 1045. Avec condenseur en verre. Minuterie 0-60 min. Sans récipients de verre et manches. Sans unité de service.
Demander une offre
Plus d’information
Objektnummer B00020603
Numéro d'identification 20603
Nom de l'objet Tecator HT2
Statut Lagergerät
Fabricant Tecator
Envoi 10-14 jours ouvrables

Statut, conditions de livraison et de paiement

Vérification des appareils

Les appareils d’occasion sont vérifiés par Labexchange Service GmbH avant la livraison. Vous recevez des appareils entièrement fonctionnels.

 

Délai d'expédition

Les délais de livraison indiqués sont les plus rapides pour l’article en cause. Les délais de fait peuvent varier au cas par cas. Les délais de livraison définitifs sont indiqués dans la confirmation de commande.

Nous offrons des livraisons collectives par principe. Le délai de livraison s’oriente à l’article avec le délai de livraison le plus long. Une livraison partielle est possible par prix additionnel.

 

Méthodes d'expédition

Courrier, agences d'expédition, autocueillette, livraison par flotte de Labexchange

 

Conditions de livraison

Prix plus frais d’expédition. Les frais d’expédition indiqués sont à prévoir. Dérogations éventuelles sont possibles.

Si les coûts de transport ne sont pas spécifiés, s'il vous plaît demander séparément les frais de transport. En cas d’expédition dans des pays situés en dehors de l’union Européenne, des frais additionnels de 70,00€ pour l’exportation sont facturés. Remarque: Nous n'établissons pas des preuves préférentielles/EUR1. Dans le cas d’un enlèvement par vos soins/EXW de pays à l’intérieur ou à l’extérieur de la Union européenne, nous devons conserver 16% de TVA d’acheteur comme dépôt de garantie, jusqu’à ce que nous ayons reçu l’attestation de reception/la prevue de livraison.

 

Modalités de paiement

Nous n’acceptons pas le paiement par carte de credit, lettre de credit, PayPal, etc. Dans tous les cas le montant est payable sans déduction. Jusqu’au paiement complèt l’équipement reste notre propriété. Un escompte n’est pas accordé.

Pays

Modalités de paiement possible

Remarque

DE, AT, CH

Paiement par facture, prépaiement

Paiement par facture est possible pour clients professionnels.

NL, BE, LU

Paiement par facture, prépaiement

Paiement par facture est possible pour clients professionnels.

Autre pays

Prépaiement

 

 

Nos conditions de vente, de livraison et de paiement sont en vigueur. Vous pouvez télécharger les documents ici.

La vente intermédiaire nous est réservée.

 

Défintion des statuts

Tous articles sont d’occasion, sauf si explicitement défini comme « appareil neuf ».

Statut

Condition

Remarque

Immédiatement disponible

Occasion

L’article a été déjà entièrement vérifié et peut être envoyé directement à vous.

En stock

Occasion

L'article est en notre stock, mais doit être vérifié avant la livraison par nos techniciens Vous recevez des articles entièrement fonctionnels.

Publié

Occasion

L’article est toujours au l’offreur. Nous achetons, vérifions et en fin livrons l’article après votre commande. Le certificat de fonctionnement ainsi que le rapport de service sont inclus à la livraison.

Appareil neuf

Neuf

C’est un dispositif neuf. L’article n’est pas utilisé et neuf d’usine. En ce qui concerne des article neufs, la garantie du fabricant est valable.

Firma:              Tecator

Modell:            HT2

Kommentar:    Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

Introduction

Extraction is used to isolate soluble matter such as Grude fat, additives, pesticides and critical minor constituents from complex materials. Extraction analysis is traditionally based an the Soxhlet principle because of its worldwide accepted ac­curacy and reproducibility. However, conventional Soxhlet analysis involves tedious and time consuming manual work and explosion risks.

The patented design of the Soxtec System HT2 makes it pos­sible to perform extractions using a wide range of solvents, in a quicker, safer and more economical way compared to Soxhlet extractions. Thus, the technique normally reduces extraction times to less than 20% of Soxhlet times and recovers 60-70% of the solvent.

High safety is ensured by external heating.

The combination of the Soxtec extraction technique and the wide range of solvent use makes the Soxtec System HT2 a flexible and powerful tool in the analysis of soluble com­pounds from materials such as: food, feed, soil, fibres, chemi­cal technical products and pharmaceuticals.

Samples to be analysed are weighed into thimbles and in­serted into the Extraction Unit. After solvent addition to the extraction cups, the soluble material is extracted into the sol­vent in a two stage process followed by a solvent recovery cycle. Finally the extraction cups are dried and weighed.

The Service Unit supplies the Extraction Unit with hot oil to achieve solvent evaporation. The tubing connecting the Ex­traction and Service Units, is deigned to withstand the use of hot oil, and allows constant temeratures. The lenght of the tubing permits the units to be placed in separate rooms.

The Service Unit is also equipped with an air pump for evaporation of the last traces of solvent from the extraction cups.


Function

The Soxtec System HT2 comprises:

-            1045 Extraction Unit

-            1046 Service Unit

-            Extraction Cups

-            Tongs for extraction cups

-            Thimbles

-            Thimble Adapter

THE 1045 EXTRACTION UNIT.

If the Extraction Unit, solvent extraction is done in two steps. At first the sample is immersed in the boiling solvent to dissolve most of the soluble material. In the second step the sample is raised above the solvent surface to permit an efficient washing of the sample with solvent from the con­densers.

After extraction the condenser valves are closed by turning the valve knobs a quarter turn. After some minutes most of the solvent is collected in the condenser. The last residue of solvent is evaporated when the air valves are opened.

THE 1046 SERVICE UNIT

The Service Unit supplies the Extraction Unit with hot oll or water from a built in tank. The heating medium is pumped from the Service Unit to the hot plates in the Extraction Unit.

In the Service Unit there is also a pump providing an air flow for solvent evaporation.

THE EXTRACTION CUPS.

The Extraction cups are made of aluminium. Never place them an a dirty surface during the analysis. This might alter the tare weight. Before use, check that the bottom of the cups are clean and undamaged, otherwise boiling might be delayed due to bad contact.

Alternatively glass cups Gould be used (part no 1000 2291).

THE THIMBLES.

The standard sizes of thimbles are 0 26x60 mm and 0 33x80 mm (the larger thimbles is normally used for sample sizes ~~5 g). Smaller thimbles are also available (0 22 mm, length 50 mm; part no 1522 0009).

TONGS FOR THE EXTRACTION CUPS.

For inserting and removing the extraction cups the tongs (Fig. C) are used.