Sold

VG Elemental ICP/MS Plasma Quad ExCell

Numéro d'identification: 019648
Statut : Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
VG Elemental ICP/MS Plasma Quad Excell. Flamme horizontale. 230 V. 50 Hz. 7,2 kW. Plug CEKON. Signe CE. Logiciel: VG Elemental Plasmalab 1.00.043 sur CDRom. P4 ordinateur. Clavier. Écran TFT. L imprimante HP Deskjet 510. Spetec Perimax pompe péristaltique, 4 canaux, tête de pompe avec 12 rouleaux. 2 Edwards pompes à vide: 1x VR 5 avec filtre 10 EMF filtres CEM, avec 1x E2M28 20e 2x pompe à vide poussé. Pour faire fonctionner l argon, \"est 99,996% et l eau de refroidissement, <10°C, 2 L/min, 3-5 bar est nécessaire. Dimensions: 114x201x70 cm. Poids: 500 kg. Sur les roues. Signe CE.
Quotation
siehe Storeview
Plus d’information
Objektnummer B00019648
Numéro d'identification 019648
Nom de l'objet VG Elemental ICP/MS Plasma Quad ExCell
Statut Stock unit

Groupe de produits: ICP / MS

Impossible de trouver des produits correspondants à votre sélection.

Statut, conditions de livraison et de paiement

Vérification des appareils

Les appareils d’occasion sont vérifiés par Labexchange Service GmbH avant la livraison. Vous recevez des appareils entièrement fonctionnels.

 

Délai d'expédition

Les délais de livraison indiqués sont les plus rapides pour l’article en cause. Les délais de fait peuvent varier au cas par cas. Les délais de livraison définitifs sont indiqués dans la confirmation de commande.

Nous offrons des livraisons collectives par principe. Le délai de livraison s’oriente à l’article avec le délai de livraison le plus long. Une livraison partielle est possible par prix additionnel.

 

Méthodes d'expédition

Courrier, agences d'expédition, autocueillette, livraison par flotte de Labexchange

 

Conditions de livraison

Prix plus frais d’expédition. Les frais d’expédition indiqués sont à prévoir. Dérogations éventuelles sont possibles.

Si les coûts de transport ne sont pas spécifiés, s'il vous plaît demander séparément les frais de transport. Les frais de transport et d'emballage indiqués se réfèrent à l'itinéraire de transport le moins cher et sont sujets à des augmentations de coûts imprévues. En raison d'événements imprévisibles, les tarifs de transport et les délais de livraison peuvent changer à tout moment et doivent être adaptés à la situation actuelle. Incoterm codage selon les Incoterms 2010: Pour personnes qui viennent chercher les dispositifs elles-mêmes: EXW, pour les expéditions par voie maritime: CFR, par avion: CPT, d'autres expéditions: DAP. Remarque: Nous n'établissons pas des preuves préférentielles/EUR1. Dans le cas d’un enlèvement par vos soins/EXW de pays à l’intérieur ou à l’extérieur de la Union européenne, nous devons conserver 16% de TVA d’acheteur comme dépôt de garantie, jusqu’à ce que nous ayons reçu l’attestation de reception/la prevue de livraison.

 

Modalités de paiement

Nous n’acceptons pas le paiement par lettre de credit, PayPal, etc. Dans tous les cas le montant est payable sans déduction. Jusqu’au paiement complèt l’équipement reste notre propriété. Un escompte n’est pas accordé.

Pays

Modalités de paiement possible

Remarque

DE, AT, CH

Paiement par facture, prépaiement, par carte de credit

Paiement par facture est possible pour clients professionnels.

NL, BE, LU

Paiement par facture, prépaiement, par carte de credit

Paiement par facture est possible pour clients professionnels.

Autre pays

Prépaiement, par carte de credit

 

 

Nos conditions de vente, de livraison et de paiement sont en vigueur. Vous pouvez télécharger les documents ici.

La vente intermédiaire nous est réservée.

 

Défintion des statuts

Tous articles sont d’occasion, sauf si explicitement défini comme « appareil neuf ».

Statut

Condition

Remarque

Immédiatement disponible

Occasion

L’article a été déjà entièrement vérifié et peut être envoyé directement à vous.

En stock

Occasion

L'article est en notre stock, mais doit être vérifié avant la livraison par nos techniciens Vous recevez des articles entièrement fonctionnels.

Publié

Occasion

L’article est toujours au l’offreur. Nous achetons, vérifions et en fin livrons l’article après votre commande. Le certificat de fonctionnement ainsi que le rapport de service sont inclus à la livraison.

Appareil neuf

Neuf

C’est un dispositif neuf. L’article n’est pas utilisé et neuf d’usine. En ce qui concerne des article neufs, la garantie du fabricant est valable.

Labprocure

Occasion

Responsable du contenu de l‘offre d’appareil est la société Labprocure GmbH, comme annonceur. Labprocure assume la responsabilité des offres annoncées ici ainsi que des photos et des textes d’offre inclus. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       VG Elemental

model :                   ICP/MS Plasma Quad ExCell

annotation :           Dokumente engl .

 

 

 

 

 

Technical Description

 

 

Instrument overview ( PlasmaQuad System)

 

The PlasmaQuad is a powerful, inductively-coupled mass spectrometer developed for the analysis of a wide variety of samples.

 

The high performance quadrupole analyser exhibits good transmission characteristics, combining optimal sensitivity and resolution with high abundance sensitivity, giving minimal interelement "cross-talk". Different parts of the spectrometer are held at different pressures to ensure correct operation of the plasma sampling interface and quadrupole mass filter. A combination of rotary and turbomolecular vacuum pumps is used to maintain these pressures.

 

The physical interface between the plasma and the mass spectrometer comprises two cones. The first cone, designated the sampling cone, is used to sample the ions created in the plasma; the second cone provides an ion skimming function. A series of cylindrical electrodes hehind the cones are designed to extract and focus Ions from the interface into the mass spectrometer. A range of alternative sample introduction facilities can be used with the PlasmaQuad , including laser ablation techniques.

 

Ions of a selected mass-to-charge ratio are transmitted by the quadrupole mass filter to a system used to detect the number of ions transmitted, and to measure and display this information in a number of ways. The ion detector comprises a channel electron multiplier with suitable amplification facilities. Pulses from the detection system are supplied to a microprocessor-controlled multi-channel scaler (MCS) data acquisition unit.

 

Overall control of instrument operation is provided by another microprocessor. The entire system is controlled via a standard communications link by a PC running special PQ Vision software. The accumulated data from the MCS is also transferred over the communications link for storage and farther processing.

 

 

 

 

Technical Details (VG PlasmaQuad )

 

The ions transmitted by the quadrupole are detected by the detector assembly. The full system is

  • a pulse counting and analogue eIectron multiplier assembly
  • a high voltage supply
  • a head amplifier assembly comprising pulse counting amplifier and associated comparator
  • an analogue amplifier and associated VFC (voltage to frequency converter)
  • signal routing multichannel scaling cards in the control unit ratemeter with meter range selection (10² Hz to 10 7 Hz)
  • multiplier protection circuits including trip indicators and manual reset ion beam defocusing grid voltage supply for multiplier protection

 

The detector is a dual simultaneous pulse counting and analogue device. For the trace analysis which is one of the great strengths of the ICP-MS technique, the multiplier is operated in the pulse counting mode. This allows individual ion arrivals to be recorded. For a large working range the pulse counting mode is augmented by a less sensitive analogue gain mode. Data is collected simultaneously in both the pulse counting and analogue modes, into the MCA. In analogue mode the output of the analogue amplifier is converted to a regular pulse train with a frequency of up to 2MHz by a voltage to frequency converter (VFC).

 

The output is sent from die head amplifier assembly to the scaler in the VG PlasmaQuad 3 control unit as a differential pair via a twisted pair transmission line. This gives good noise immunity.

 

A positive ion striking the first dynode causes the ejection of one or more secondary electrons from the surface, which are accelerated down the tube. Collisions with other dynodes liberate further electrons and as the gain for this process is generally greater than unity, the avalanche builds up exponentially. Towards the bottom of the detector, the avalanche process reaches saturation. The space charge of electrons that builds up during the pulse becomes sufficient to inhibit further rnultiplication , so that the output pulses tend to be grouped around a standard size (about 15 picocoulombs ).

 

With these high electron fluxes, residual gas is likely to be ionised . High electron currents will ultimately damage individual dynodes, so a charged grid mounted within the body of the detector can stop the build up of large fluxes. If it were not for the orientation of the dynodes, these ions might be accelerated back to the entrance to start another avalanche and the process, called ion feedback would repeat, giving a very long output pulse. Even with this detector design, it is important not to operate the multiplier with a high residual gas pressure (such as would be the case if insufficient pumpdown time was allowed) because die ionic feedback mechanism will produce an undesirably high gain.

 

The cloud of about 10 7 to 10 8 electrons leaves the base of the channel and is collected by the collector electrode. A decoupling capacitor isolates the - 150V DC voltage at the exit of the multiplier from the pulse counting amplifier.

 

Ultimate detection limits are determined only by the counting statistics of the random background counts. These result when multiplier electron avalanches are initiated by species other than the analyte ions of interest. This background rate can be as low as 5 Hz, but does vary considerably from one individual multiplier to another. A discriminator threshold level may be set which eliminates electronic noise almost entirely, while passing most of the real pulses. This is achieved by a comparator which compares the output of the amplifier with a reference level sent from the VG PlasmaQuad 3 control unit.

 

The allowed discriminator levels 1 to 255 correspond to the range 0.08 to 20mV. The required value can be found by operating the instrument with all noise sources on (ICP, quadrupole , computer) and pulse counting mode selected, but with the high voltage off. As increasing discriminator settings are sent from the data system, the electronic noise level should be seen to drop to zero on the ratemeter . Typical values to achieve this lie between 10 and 30. A trial scan in pulse counting mode with the chosen discriminator level set and with the multiplier HT disabled should show no counts.

 

Having set the discriminator level, it is then possible to set the correct operating voltage for pulse counting operation. With a modest ion flux (a few tens of kHz) incident on the detector and the pulse counting mode selected, the voltage can be carefully increased and the signal observed. The choice of operating voltage is a compromise between achieving best multiplier lifetimes, which implies tower settings, and keeping the pulse height distribution well above the discriminator level so that excessive counts are not lost when the gain is suppressed by high count rates, which implies higher settings.

 

 

 

 

 

 

Technical Data (12000 ICP Power Supply Operator’s Manual)

 

Output Frequency:

27.12 MHz

 

Frequency Stability:

0.005% Short Term

 

RF Power Output

2000 Watts into a 50 Ohm load

 

Output Impedance:

50 Ohms +/- 5 Ohms

 

Metering Accuracy:

Forward: +/- 1% Full Scale, +/- 3% of reading

 

Temperature Coefficients:

0.025% per °C

 

Output Connector:

Type N female

 

Power Stability:

0.1% Long Term @ 25°C typical

 

Regulation:

-45dBc into 50 Ohm load

 

Line Regulation:

No change from 198-250VAC.

 

Load Tolerance:

No oscillation or failure into a mismatch

 

Noise, Hum, and Ripple:

-45dBc

 

Harmonie Distortion:

All harmonics less than -50dBc

 

Spurious Radiation:

Meets or exceeds FCC and VDE regulations

 

Operating Temperature/Humidity:

0 to +40°C, 10% to 90% relative humidity, non-condensing.

 

Power Required:

180-250VAC, 47-63Hz, Single Phase,

20Amps maximum, 3100 Watts maximum,

Power factor: 0.99

 

Over Current Protection:

Circuit breaker, 20 Amp over-current, 1000 Amp interrupt capacity

 

Overall Dimension, inch (cm):

8.75 (22.23) High x 19 (48.26) Wide x 19(48.26) Deep, including fan

 

Weight:

60 LBS / 27.2Kg

 

Cooling:

Air, 235 CFM fan below 11,000 feet

 

Power Cord:

Standard: 12 AWG 600V type SOW, length: 6 feet / 183crn (custom cord configurations available)

 

Power Cord Connector

Standard: 20 Amp 250V twist-lock, male, NEMA type L6-20P (custom connector configurations available)

 

Analog Interface Connector:

15-pin female D-subminiature connector.

 

 

 

 

 

 

 

 

 

 

 

 

 