WTW LF 296 TRS
Objektnummer | B00011474 |
---|---|
ID-number | 011474 |
Object name | WTW LF 296 TRS |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: WTW
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.
Display
Measured value LCD 7 segment
‧ χ 3½-digit
‧ Temperature 4-digit
Units, settings Symbols
χ measurement
Cells that can be connected 2 or 4-electrode cells
Display and measuring Up to 1000 mS/cm depending on the sensor type
range
Measured value resolution 0.001 µS/cm ... 1 mS/cm (according to the measuring
range)
Accuracy ± 0.5% from measuring value ± 1 digit
Automatic temperature - 5°C ... + 60°C
Compensation (TetraCon ® 700, 600, 300)
- 5°C ... + 130°C
(0.01 cm -1 ; 0.1 cm -1 ; 10 cm -1 ; 1 cm -1 )
Reference temperature + 20°C; + 25°C configurable
Calibration Calibration against the standard by changing the cell constant:
± 10 % (TetraCon ® 700, 600 und 300)
± 50 % (Cell constant 10 cm -1 )
0.09 cm -1 ... 1.5 cm -1 in the variable setting of the cell constant
Salinity measurement
Display and measuring 0.0 ... 70.0
range
Measured value resolution 0.1
Reference temperature 20 °C
Temperature measurement
Temperature sensor NTC
Accuracy ± 0.2 K ± 1 digit
Additional fine adjustment of ± 0.5 K
Resolution 0.1 K
Inputs / outputs
digital Interface RS-485; 2(3)-wire connection bus operation with up to 31 units is possible
Sensor input 7-contact round plug connector with screw fixing
Contact outputs Relay 1/ Relay 2 Functions, limit controller
max. switching voltage 250 VAC
max. switching current 5 A
max. switching capacity 150 W (ohmic load)
Signal outputs 0/4 to 20 mA; electrically isolated from the input
Recorder ranges and recorder attenuation can be set via software
Basic accuracy 0.1%
Load max. 600 Ohm
Load effect < 0.1 %
Connector terminals Accessible after opening the instrument;
Cable inlet by 4 PG screws
Connector cross section 0.5 to 2.5 mm²
Power supply 2-contact
Relay ½ each 2-contact
SENS Check 2-contact
Recorder connections each 2-contact
Sensor 6-contact
Protection type
Lightning protector Coarse protection 90 V / 1.5 KA (8/20µs)
(inputs and outputs) Fine protection 600 Watt
Electrical instrument Safety class 2 according to IEC 1010
protection
Housing IP 54
Electrical connection data
Voltage supply 230 VAC ( 15% + 10%)
(depending on the instrument 115 VAC ( 15% + 10%)
version) 24 VAC ( 15% + 10%)
24 VDC ( 30% + 20%)
Frequency 48 to 62 Hz
Power consumption Max. 18 Watt
Test certificates CE (for all supply voltages)
Interference suppression According to EN 50081-1, FCC class A
Interference immunity According to EN 50082-2, Namur recommendations
Ambient temperature
Limits of operating range 25 °C to + 55 °C
Storage and transport 25 °C to + 65 °C
temperature
Climate class Climate class 4, VDI / VDE 3540 Bl.2
Mechanical data
Dimensions 96 x 96 x 168 mm (B x H x T)
(height in parentheses without PG screws)
Weight Approx. 1.1 kg
Keypad (material) Polyester
Housing (material) Fiber-reinforced Noryl