Archive

WTW LF 296 TRS

ID-number: 011474
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
WTW Conductivity Measuring instrument LF 296 TRS. YoC: 2001.
siehe Storeview
More Information
Objektnummer B00011474
ID-number 011474
Object name WTW LF 296 TRS
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              WTW

Modell:            LF 296 TRS

Kommentar:    Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.

Display

Measured value                            LCD 7 segment

                                                    ‧ χ 3½-digit

                                                    ‧ Temperature 4-digit

Units, settings                              Symbols

χ measurement

Cells that can be connected        2 or 4-electrode cells

Display and measuring                Up to 1000 mS/cm depending on the sensor type

range

Measured value resolution           0.001 µS/cm ... 1 mS/cm (according to the measuring

                                                    range)

Accuracy                                      ± 0.5% from measuring value ± 1 digit

Automatic temperature                • - 5°C ... + 60°C

Compensation                             (TetraCon ® 700, 600, 300)

                                                    • - 5°C ... + 130°C

                                                    (0.01 cm -1 ; 0.1 cm -1 ; 10 cm -1 ; 1 cm -1 )

Reference temperature               + 20°C; + 25°C configurable

Calibration                                    Calibration against the standard by changing the cell     constant:

                                                    • ± 10 % (TetraCon ® 700, 600 und 300)

                                                    • ± 50 % (Cell constant 10 cm -1 )

                                                    • 0.09 cm -1 ... 1.5 cm -1 in the variable setting of the cell             constant

Salinity measurement

Display and measuring                0.0 ... 70.0

range

Measured value resolution           0.1

Reference temperature               20 °C

Temperature measurement

Temperature sensor                    NTC

Accuracy                                      ± 0.2 K ± 1 digit

                                                    Additional fine adjustment of ± 0.5 K

Resolution                                    0.1 K

Inputs / outputs

digital Interface                             RS-485; 2(3)-wire connection bus operation with up to 31         units is possible

Sensor input                                 7-contact round plug connector with screw fixing

Contact outputs                           Relay 1/ Relay 2                 Functions, limit controller

                                                    • max. switching voltage    250 VAC

                                                    • max. switching current    5 A

                                                    • max. switching capacity   150 W (ohmic load)

Signal outputs                              0/4 to 20 mA; electrically isolated from the input

                                                    Recorder ranges and recorder attenuation can be set via          software

                                                    • Basic accuracy                0.1%

                                                    • Load                                 max. 600 Ohm

                                                    • Load effect                       < 0.1 %

Connector terminals                    Accessible after opening the instrument;

                                                    Cable inlet by 4 PG screws

                                                    Connector cross section   0.5 to 2.5 mm²

                                                    • Power supply                   2-contact

                                                    • Relay ½                            each 2-contact

                                                    • SENS Check                    2-contact

                                                    • Recorder connections     each 2-contact

                                                    • Sensor                              6-contact

Protection type

Lightning protector                       • Coarse protection 90 V / 1.5 KA (8/20µs)

(inputs and outputs)                     • Fine protection 600 Watt

Electrical instrument                    Safety class 2 according to IEC 1010

protection

Housing                                        IP 54

Electrical connection data

Voltage supply                              • 230 VAC (– 15% + 10%)

(depending on the instrument      • 115 VAC (– 15% + 10%)

version)                                        • 24 VAC (– 15% + 10%)

                                                    • 24 VDC (– 30% + 20%)

Frequency                                    48 to 62 Hz

Power consumption                     Max. 18 Watt

Test certificates                           CE (for all supply voltages)

Interference suppression             According to EN 50081-1, FCC class A

Interference immunity                  According to EN 50082-2, Namur recommendations

Ambient temperature

Limits of operating range             – 25 °C to + 55 °C

Storage and transport                  – 25 °C to + 65 °C

temperature

Climate class                               Climate class 4, VDI / VDE 3540 Bl.2

Mechanical data

Dimensions                                  96 x 96 x 168 mm (B x H x T)

                                                    (height in parentheses without PG screws)

Weight                                          Approx. 1.1 kg

Keypad (material)                        Polyester

Housing (material)                       Fiber-reinforced Noryl

Product group: Conductivity meters