Sold

Waters M 616

ID-number: 010591
Status: Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
Waters quarternary HPLC-Pump M 616. YoC: 1998.
Quotation
siehe Storeview
More Information
Objektnummer B00010591
ID-number 010591
Object name Waters M 616
Status Stock unit

Product group: HPLC-Pumps (gradient)

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Waters

Modell:            M 616

Kommentar:   Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.

Intended use

The 616 Pump can be used for in-vitro diagnostic testing to analyze many compounds, including diagnostic indicators and therapeutically monitored compounds.

Waters 616 LC System Overview

Features common to 616 LC systems

The Waters 616 LC system includes the following features:

• 50 µL pump head volume

• Maximum system pressure: 5000 psi (351.5kg/cm 2 )

• 0.01 to 5.0 mL/min operating flow rate

• Four-eluent gradient capability (Auto•Blend ä method)

• Automatic eluent degassing by helium sparge

• Pump vent valve to facilitate priming and purging of eluent lines and changing eluents

• Rheodyne 7725i (616 LC system) variable-volume, syringe-loading sample injector

• Automated, continuous plunger seal wash with integral pumping system

• Single keypad control with PowerLine system controller

• Methods storage allowing access to previously created gradient, event, autosampler, and detector programs

• 11 preprogrammed gradient profiles including:

• Step change at start of segment

• Step change at end of segment

• Linear change

• Four convex gradient curves

• Four concave gradient curves

• System control of PowerLine detectors and autoinjectors through IEEE-488 interface

• RS-232 serial communications interface for connection to optional integrator

• Optional shelf unit to house system modules.

• SILK pumping technology for pulse-free flow

• Optional column heater monitoring

• Low-dispersion system volume for rapid eluent changeovers and narrow-bore/microbore separations

616 overview

The Waters 616 LC system:

• Is a High Performance Liquid Chromatography (HPLC) pumping system for microbore, narrow-bore, and analytical chromatography and micropurifications

• Uses 0.005- and 0.009-inch I.D. stainless steel tubing to optimize system performance

• Performs complex methods with less eluent and in less time than semi-preparative systems

Waters 600S Controller

Controls eluent gradient, flow rate, external events, and sparging for the Waters 616 LC system.

Provides connection terminals and communication ports for operation with and control of external devices, such as detectors, autosamplers, and data systems.

Waters 616 Pump

Contains components required to blend and to deliver eluents from the eluent reservoir bottles to the injector and column.

Consists of the pump with 50-µL volume pump heads, plunger wash pump, eluent sparge valve assembly, eluent proportioning valve assembly, manual injector, and vent valve.

Rheodyne 7725i Injector (optional)

Contains one 20-µL sample loop.The 616 LC system Startup Kit includes 5-µL, 50-µL, and 200-pL sample loops.

You can also purchase 5-, 10-, 20-, and 100-µL sample loops.

Vent Valve

Allows you to direct flow from the pump directly to waste, or through the injector, columns, and the rest of the system.

Operational Specifications

Number of Eluents

One to four

Modes of Operation

Gradient, isocratic, and flow programming

Programmable flow range

0.00 to 10 mL/min (50 µL heads), in 0.01 mL increments

Operating Flow Range (typical)

0.00 to 5.00 mL/min (50 µL heads), in 0.01 mL increments

System Volume

Without mixers - <400 µL (616), <500 µL (626)

With mixers (GM-150) - <700 µL (616), <750 µL (626)

Composition Range

0 to 100% programmable in 1% increments for each of four reservoirs: A, B, C and D. Total composition must sum to 100%.

Compositional Accuracy

Better than 1.0%, independent of pressure

Automatic Eluent Sparging

Standard, helium gas, input gas pressure range 50 to 150 psi (3.5 to 10.5 kg/cm 2 ).

Helium flow rate range 0 to 100 mL/min, programmable in 1 mL/min increments.

Pressure Maxima

616 Pump: 5000 psi (351.5 kg/cm 2 ) over flow rate range

Programmable Pressure Limits

Pump lower: 0 to 4950 psi (0 to 348.0 kg/cm 2 )

Pump upper: 51 to 5000 psi (3.6 to 351.5 kg/cm 2 )

Plunger Seal Wash

Approximately 80 µL/min intermittent and automatic

Program Storage

Storage for 15 sets of tables (gradient, program event, and detector), with a maximum of 15 steps per table.

Storage for a time-based multi-method program with up to 48 individual steps.

EEPROM stores setup parameters and tables, and preserves memory indefinitely following power loss or extended shutdown.

Gradient Profiles

Eleven gradient curves (including linear, Step [2], concave [4], and convex [4]). Up to 80 curve segments can be linked.

Liquid Crystal Display (LCD)

5-inch (12.7 cm) diagonal screen.

Sixteen lines with 40 characters per line.

320 x 200 pixels.

Displays current operating conditions.

Allows operator to monitor complete gradient and timed-event tables on single screens.

Reverse video cursor prompts operator through program setup.


Keypad, Function Keys, and Screen Keys

Dedicated keys provide direct access to all display screens. Cursor movement keys simplify programming, editing, and parameter entering. All keys are eluent-resistant.

Programmable Timed Events

You can program and store 15 timed events for each table.

Contact closure switches S1 through S4 are located on the 600S controller rear panel for timed output to external devices.

The following actions may also be controlled by timed events:

• Audible alarm

• Sparge rate

• Column temperature

• Proceed to initial conditions of specifed table

• Start run of specified table

• Turn detector lamp off

Electrical Specifications

Power Requirements

Maximum power: 250 VA

Frequency:

47 to 63 Hz

Environmental Specifications

Temperature

Operating Range: 4 to 38°C (39.3 to 100.4°F)

Storage Range: 0 to 50°C (32 to 122°F)

Humidity

Operating Range: 20 to 90% Relative Humidity

Storage Range: 0 to 90% Relative Humidity (non-condensing)

Eluent Compatibility

Compatible with eluents consistent with materials of construction

Physical Specifications

Wetted Surface Material

Stainless steel (616 LC system)

Controller

Height: 7.19 inches (18.26 cm)

Depth: 21.75 inches (55.25 cm)

Width: 11.32 inches (28.75 cm)

Weight: 33 Ib (15 kg)

Pump

Height: 9.625 inches (24.4 cm)

Depth: 20.5 inches (52.1 cm)

Width: 11.125 inches (28.3 cm)

Weight: 60.2 Ib (27.3 kg)