HPLC-Systems

Waters Acquity UPLC System with 2996 PDA Detector,

Preis auf Anfrage
ID-number: 15540
Status: LabprocureLabprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.?
Shipping: 4-6 weeks
Description:
Waters Acquity 2996 PDA detector. wavelength range. 190 to 800 nm. Light source. Pre-aligned deuterium lamp. Spectral resolution / optical bandwidth. 1. 2nm per photodiode with a total of 512 photodiodes, digital and optical (3D mode). Digital resolution. 1. 2nm - 600nm (2D mode). Wavelength accuracy. ±1 nm. Linearity range. 5% at 2.0 AU, propylparaben, at 256 nm. Spectral resolution. 1. 2 nm. noise floor. ±1. 5 × 10-5 AU peak to peak, dry, at 254 nm. Drift. 1 × 10-3 AU/hour at 254 nm (after warming up) ?T ? 1°C per hour. Operating temperatur. 4 to 40°C (39 to 104°F), varying no more than 1°C per hour (to avoid drift). Relative humidity. 20 to 80%, non-condensing. Energy. Grounded AC, 100 to 240 Vac. Electricity requirement. 100-230VAC. Frequency range. 50 to 60 Hz. Path length. 10mm (standard analytical cell). Cell volume. 8 µl (standard analytical cell). pressure limit. 1000 psi (standard analytical cell). Humidified materials. 316 stainless steel, fused silica Tefzel. Dimensions. Width: 11.5 inches (29 cm) Depth: 24 inches (61 cm) Height: 8.5 inches (22 cm). Weight. 31. 5 lbs (14. 3 kg). Waters Sample Template Manager. Injection volume range. 0. 1 to 10. 0 µL as standard configuration. Up to 1000.0 µL with optional expansion loop. Accuracy. +0. 2 µL measured by the weight of fluid removed from the vial in 10. 0 µL injections averaged over 20 injections using standard 100 µL syringe. Injection linearity. >0. 999 (see ACQUITY UPLC I-Class System Specification Document for conditions). Maximum sample capacity. Two of each of the following:. 96 and 384 microtiter plates. 48 positions 2.00 mL vial plates. 48 positions 0. 65 mL microcentrifuge tube plates. 24 positions 1. 50 mL microcentrifuge tube plates. Temperature range of the sample compartment. 4. 0 to 40. 0°C. Adjustable in 0. 1°C increments. Maintains 19°C below ambient temperature with a tolerance range between -2 and 4°C. Temperature accuracy. +0. 5°C on the sensor. Temperature stability. +1. 0°C at the sensor. Wash the injection needle. Integrated, active, programmable. Minimum sample required. 3µL remainder, with Waters' 2-mL vials for total recovery. Transmission (UV). <0. 004% <0. 001% typical. Advanced sample manager capabilities. Automatic dilution and automatic addition. Primary wetted materials. 316L stainless steel, polyimide, PEEK blend, DLC, PPS. Waters Binary Solvent Manager. Number of solvents. Up to four, in combination of two, A1 or A2 and B1 or B2. Solvent conditioning. Integrated vacuum degassing, six lines, two of which are reserved for washing/rinsing the injection needle. Gradient formation. High pressure mixing, binary gradient. Gradient profiles. 11 gradient curve [including linear, step (2), concave (4) and convex (4)]. Primary check valves. Intelligent intake valves. Flow accuracy. +1. 0% of the set flow rate at 0. 500 mL/min, according to SystemsQT. Flow precision. 0.075% RSD or 0.01 min SD, (0.2 to 2.0 mL/min), whichever is greater, with premixed solvent. Composition rib (baseline noise). <1. 0 mAu. Pump composition precision. <0. 2% RSD, or 0.02 min SD, whichever is greater (from 0.2 to 2.0 mL/min). Pump composition accuracy. +0. 5% absolute from 5% to 95%, 0. 2 to 2. 0 mL/min. Compressibility compensation. Automatic, no user intervention required. Priming. Wet priming runs at a flow rate of 4 mL/min. Pump seal washing. Equipped with a programmable active wash system to flush the back of the high pressure seals and pistons. River ramp. Automatically. Primary wetted materials. 316L stainless steel. UHMWPE blend. MP35N. Titanium alloy. Gold. Sapphire. Ruby. Zirconia. Nitronic 60. DLC. Fluoropolymer. PEEK and PEEK blend. 316L Stainless Steel, UHMWPE Blend, MP35N, Titanium Alloy, Gold, Sapphire, Ruby, Zirconia, Nitronic 60, DLC, Fluoropolymer, PEEK and PEEK Blend. Blend options. Standard: 50 µL. Optional: 100 µL and 380 µL. This Waters UPLC system includes:. Waters 2996 PDA detector. Waters Sample Template Manager. Waters binary solvent manager. This refurbished Waters UPLC system is in perfect condition. We have special expertise in the field of analysis technology. Labprocure is responsible for this device.
Quotation
More Information
Objektnummer C00015540
ID-number 15540
Object name Waters Acquity UPLC System with 2996 PDA Detector,
Status Labprocure Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.
Manufacture Waters
Shipping 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Product group: HPLC

Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
lazyOwllazyOwl
Labprocure