Description:
Waters quarternary HPLC-Pump 616. YoC 1999.
Quotation
siehe Storeview
More Information
Objektnummer B00012826
ID-number 012826
Object name Waters 616
Status Stock unit

Product group: HPLC-Pumps (gradient)

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                Waters

Modell:              616

Kommentar:      Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

The Waters 616LC system is a High-Performance Liquid Chromatopraphy (HPLC) pumping system for microbe, narrow-bore, and analytical chromatography and micropurifications.

Uses 0.005 and 0.009 inch I.D. stainless steel tubing to optimize system performance.

Performs complex methods with less eluent and in less time than semi-preparative systems.

Features

- 50 µl pump head volume

- Maximum system pressure: Pump 616: 6000 psi (420kg/cm 2 )

- 0.01 to 5.0 mL/min operating flow rate

- Four-eluent gradient capability (Auto Blend method)

- Automatic eluent degassing by helium sparge

- Pump vent valve to facilitate priming and purging of eluent lines and changing eluents

- Rheodyne 7725

- Automated, continuous plunger seal wash with integral pumping system

- Single keypad control with PowerLine system controller

- Methods storage allowing access to previously creafed gradient, event, autosampler, and

   detector programs

- 11 preprogrommed gradient profiles including:

--   Step change at Start of segment

--   Step change at end of segment

--   Linear change

--   Four convex gradient curves

--   Four concave gradient curves

- System control of PowerLine detectors and autoinjectors through IEEE-488 interface

- RS-232 serial communications interface for connection to optional Integrator

- Optional shelf unit to hause system modules.

- SILK pumping technology for pulse-free flow

- Optional column heater monitoring

- Low-dispersion system volume for rapid eluent changeovers and norrow-bore/microbore

  Separations

Waters 600S Controler

Controls eluent gradient, flow rate, external events, and sparging for the Waters 616 LC system.

Provides connection terminals and communication ports for Operation with and control of external devices, such as detectors, autosamplers, and data Systems.

Waters 616 Pump

Contains components required to blend and to deliver eluents from the eluent reservoir bottles to the injector and column.

Consists of the pump with 50-µL volume pump heads, plunger wash pump, eluent sporge volve assembly, eluent proportioning valve assembly, manual injector, and vent valve.

Rheodyne 7725i Injector (optional)

Contains one 20-µL sample loop. The 616 LC system Startup Kit includes 5-µL and 200-µL sample loops.

You can also purchase 5-, 10-, 20-, 50-, and 100-µL sample loops.

Vent Valve

Allows you to direct flow from the pump directly to waste, or through the injector, columns, and the rest of the system.

Physical Specifications

Wetted Surface Material

Stainless steel (616 LC system)

Controller

Height:      7.19 inches (18.26 cm)

Depth:      21.75 inches (55.25 cm)

Width:       11.32 inches (28.75 cm)

Weight:     33 lb (15 kg)

Pump

Height:      9.625 inches (24.4 cm)

Depth:      20.5 inches (52.1 cm)

Width:       11.125 inches (28.3 cm)

Weight:     60.2 lb (27.3 kg)


Optional equipment:

Photodiode Array Detector 996

Obtaining complete spectral data no longer means compromising chromatographic sensitivity. The 996 PDA Detector has the chromatographic sensitivity of even the best tunable UV/Vis wave­length detector. Trace amounts of sample and minor impurities can be detected and quantitated accurately.

Advanced optics enhances sensitivity und detectability

Optical design innovations enable the use of 10 mm flow cells to provide a 67% increase in observed absorbance over PDA detectors with 6 mm flow cells.

The 996 PDA Detector flow cell features the patented Toper-Beam technology that reduces refractive index effects at the eluate/flow cell interface. This technology focuses maximum light intensity on the diode array and improves detectability by reducing noise resulting in improved sensitivity. What's more, advanced mathematical algorithms for the 996 detector improve detection by reducing baseline noise (Figure 5B).

Lamp optimization software maintains high signal-to-noise ratio

Reducing baseline noise is a key element in maximizing compound detection. To ensure consistent performance over time, special software unique to the 996 PDA detector automatically maintains a minimal noise level over the lifetime of the lamp The software selects an appropriate exposure time for the diodes based on lamp energy, mobile phase and wavelength-range. This optimization, automatically performed before each injection, requires no manual adjustments to the detector operating current, slit width, or diode resolution.

Waters 996 Photodiode Array Detector Gives You Confidence - Erases the Doubts.

You're developing an HPLC method for analyzing the composition of a high-value-added fine chemi­cal. You're responsible for developing methods to check for impurities in a drug to treat hypertension. You ve been given the task of isolating a compound taken from a rare plant that is known for its curative powers.

With challenges like this, you may have to place your reputation and that of your lab at stake. Can you afford not to invest in technology that gives you confidence in your ability to deliver results that are the best they can be?

How do I know if this substance is really pure or isn't something else?

With Waters 996 Photodiode Array Detector, you can be confident that if there is an impurity in your sample, you'll find it; that your compound is really what you report it to be and not something else. Every spectral detail of your sample is rapidly, easily, and accurately detected. Every peak is analyzed with mathematical precision so you can be sure your ability to assess the purity of peaks and confirm their identity is state-of-the art. And you will never have to trade off resolution for sensitivity.

Confidence in results through technological innovation

The 996 Photodiode Array Detector represents the most powerful combination of software and optics uniquely integrated to provide speed, detectability, and ease-of-use. Built into the 996 PDA Detector are technological innovations for obtaining the most complete and accurate spectral data of any photodiode array detector available today - designed to greatly enhance your ability to do more with the time you have and give you more confidence in the integrity of your results.

• Absorbance measurement over the entire 190-800nm wavelength range (or for any pre-selected wavelength range) to-obtain as detailed a spectral map as possible.

• Powerful Millennium ® software routines with advanced mathematical algorithms give you the rare ability to see the finest spectral details of even trace analytes. With Millennium Software you can extract wavelengths, calibrate, quantitate, determine peak purity, perform library com­parisons, check system suitability, calculate RSD's, print custom reports and export all data automatically and without time consuming, post-run, manual calculations.

• Advanced Taper-Beam optics for exceptional signal-to-noise performance and the linearity you need to analyze major peaks and minor impurities in the same run.

Validation and quality begin with our ISO 9000-certified manufacturing process

To assure product quality, reliability, und consis­tency, Waters instruments, data management sys­tems und chemical products are developed and manufactured in accordance with Waters Total Quality Management (TQM) programs. Manufacturing operations are defined by written SOP's und specifications und are cerfified to ISO 9000 International Quality Management Standards und comply with cGMP requirements, Certificates of Validation are supplied with most products to verify that product design has been validated using a System Development Life Cycle (SDLC) process.

From installation to scheduled maintenance, Waters expertise in compliance und quality management is available to assist you in meeting ISO 9000 and regulatory requirements.

Qualification workbooks from Waters form the foun­dation for your Laboratory Validation Master Plan. Module and system level SOP's (IQ, OQ, PQ) guide you through installation, operation and main­tenance for both instrument und data products.

Specially trained and certified Validation Support Specialists are available to assist you by providing maintenance and qualification services.

Optional Preventative Maintenance und Total Protection Service Plan coverage can be enhanced to include qualification services.


Operating Specifications

Wavelength range                            190-800 nm

Light source                                      Deuterium arc lamp

Spectral resolution                            1.2 nm per photodiode (digital and optical)

Wavelength accuracy                       ± 1 nm

Linearity range                                  5% over-0.1 to 2.0 AU

                                                         Propyl paraben, 257nm

Baseline Noise                                  ±1.5 X 10 5 AU at 254 nm (10mm cell)

Drift                                                   <1 X 10 3 AU/hour at 254 nm

Sensitivity setting range                    0.0001-2.0 AUFS (under software control)

Taper Beam flow cells                      Cell Pathlength/volume

                                                         Standard analytical       10 mm/ 8 µl

                                                         Semi preparative          3 mm/2.5 µl

                                                         Inert                               10 mm/8 µl

                                                         High pressure               10 mm/8 µl

                                                         Microbore                      3 mm/2.5 µl

Outputs                                             Two analog integrator outputs

                                                         Two programmable event outputs

Physical/Environmental Specifications

Dimensions                                      Width:11,5 inches (29 cm)

                                                         Height: 5;9 inches (15 cm)

                                                         Depth: 22 inches (56 cm)

Weight                                              34 lb. (15,4 kg)

Temperature                                     Operating: 4 to 40°C (39 to 104°F)

Humidity                                            Operating: 20 to 80%, non-condensing programmable         lamp shutoff

Electrical Specifications/Requirements

Power requirements                         115 VAC (90-132 V), 50/60 Hz

                                                         230 VAC (190-264 V), 50/60 Hz

Power consumption                         100 VAC (nominal)


Optional

Autosampler 717 Plus

Description

The Waters 717plus Autosampler injects samples into a high performance liquid chromatography (HPLC) system. The Waters 717plus automates sampling by storing up to 96 sampling methods or "steps". Each method controls all injection parameters for a sequence of vials.

The Waters 717plus may be used as either a stand-alone unit or as a component in a Waters IEEE-488 based HPLC system. As part of an IEEE-488 based system, the autosampler may be controlled by Waters PowerLine­ System Controllers or Waters Data Workstations.

The Waters 717plus autosampler features:

Sample carousels and vials

Two carousel sizes:

•     48-vial carousel - Holds 4 mL sample vials

•     96-vial carousel - Holds 1 mL sample vials

Multi-method automatic sampling

An auto sampling multi-method may contain:

•    Up to 96 steps, with each step containing a different sampling method

•     Random access to any single or series of vials

Priority (Stat) sampling

The Stat function:

•     Interrupts a programmed sampling method.

•     Performs injections from a single vial or a series of vials.

•     Returns to the interrupted sampling method, and continues auto sampling from the Interruption point.

Automation options

The 717plus allows you to program the following options:

•     Auto Addition - Allows you to inject a common solution with each sample.

•     Auto Standards - Allows you to run standards automatically during a run.

•     Auto Transfer -Allows you to program the 717plus to transfer solutions from specified           vials to your sample vial; to mix the solution; and to inject.

Interaction with other LC modules

The Waters 717plus sends and receives signals from other LC modules, including:

•     Inject Start - Occurs when the sample is injected into the mobile phase stream. Initiates data acquisition, fraction collection, and detector autozero. Contact closure is initiated by the autosampler.

•     Inject Stop - Occurs when the programmed run time expires. Signals data integrators that the chromatography run is complete. Contact closure is initiated by the autosampler.

•     Hold - Halts the autosampler until the signal changes. Can be used to prevent sample injections if an LC system module fails or while a data acquisition system is preparing for the next run. Signal is received from external devices.

•     Report Delay - Delays the next injection until a data integrator can complete a report for the previous run. The delay is a programmable interval that occurs after the Inject Stop signal.

•     Programmable Event - The 717plus includes a programmable event output that can control external devices during a run.

IEEE-488 bus communication

As part of a Waters IEEE-488 system, the Waters 717plus autosampler accepts programming and control signals from an LC System controller.

RS-232 communications

The Waters 717plus autosampler sends data over an RS-232 communication line. The data is in ASCII format.

Purge and compression

Purge and compression testing copability includes:

• Purge - Fills the sample loop and iniection syringe with fresh mobile phase.

• compression - Tests the sample loop for gas content (compressibility). Compressibility limits may be set for specific mobile phases. Testing may be automatic or Operator initiated.

           

Needle wash system        

•            Prevents Cross-contamination of samples

•            Extends seal life by removing the mobile phase and the sample from the sampling needle

Semiprep chromatography

For semiprep chromatography (up to 2 mL iniections), the 717plus autosampler may be configured with optional:

•            2000 µL sample loop - Required for iniections greater than 200 µL

•            2500 µL syringe - Speeds pre-iniection sequence for samples greater than 150 µL

Microbore (<1µL) Chromatography

For microbore chromatography, the 717plus autosampler may be configured with:

•            25 gL syringe for improved iniection volume precision below 1.0 µL

•            Low volume sample vials

Syringe speed

The autosampler syringe speed is adiustable for each syringe size and allows you to adiust for sample viscosity.

Heater/Cooler

The Waters 717plus Autosampler may be configured with a heater/cooler to maintain constant sample compartment temperature from 4 to 40°C.

Weight

Requires a bench capable of supporting at least 75 lbs.

Power requirements

Requires 6 Amps at 110 Vac (nominal) or 3 Amps at 220 Vac (nominal) from a grounded outlet.