Archive

Waters 6000 A

ID-number: 011045
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Waters HPLC-Pump M 6000 A. Flowrate: 0,1-9,9 ml/min.
siehe Storeview
More Information
Objektnummer B00011045
ID-number 011045
Object name Waters 6000 A
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Waters

Modell:                         6000 A

Kommentar:     Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

BENEFITS OF THE MODEL 6000A SOLVENT DELIVERY SYSTEM

The Model 6000A Solvent Delivery System (Figure 1-1), referred to as the Model 6000A, is a high-performance solvent delivery System de­signed specifically for liquid chromatography applications. Constant flow of the solvent delivery is achieved with a pair of specially­driven positive-displacement pumping chambers. Flow rate is manually selectable in 0.1-milliliter-per-minute increments from 0.1 to 9.9 milliliters per minute (ml/min). An auxiliary electrical connection enables the flow rates to be programmed automatically by the Waters Model 660 Solvent Programmer. The maximum output pressure is 6000 pounds per square inch gauge (psig) with the overpressure limit adjustable from 100 to 6000 psig (7 to 420 bars).

Because of the low internal volume of the Model 6000A, solvent change­over time is minimized and recycle Operation is permitted. For example, each piston in the pair of pumping chambers only displaces 100 microliters of solvent per stroke.

Electronic control of piston reciprocation rate governs the solvent flow rate. Variations in line voltage and line frequency do not affect Model 6000A Operation. Solvent viscosity and System elas­ticity are automatically compensated to ensure a steady solvent flow.

The Model 6000A is available for Operation on one of two nominal supply voltages: 115 Vac, 50/60 Hz (part No. 25990) or 220 Vac, 50/60 Hz (Part No. 25991). Converting from one supply voltage to another can be done by your local Waters Associates Field Service specialist.

PHYSICAL DESCRIPTION

The Model 6000A is packaged as one module which can be disassembled into two functional sections -- the Pump Unit and the Electronics Unit (see Figure 1-2). Hydraulic assemblies and connections are readily accessible on the front of the Pump Unit. Operating controls are conveniently placed on the front of the Electronics Unit.

FUNCTIONAL DESCRIPTION

SOLVENT HYDRAULICS

Figure 6-1 illustrates the solvent pumping operation of the Model 6000A. Solvent from the reservoir(s) is pulled into the inlet mani­fold assembly, through a filter and check valve, and into both pump head assemblies. Pistons, in the fixed displacement chambers of the pump head assemblies, are driven alternately in a push-pull arrange­ment. Inlet and outlet check valves in each pump head assembly ensure that one piston can draw in solvent while the other piston delivers solvent, and that the solvent will not flow back toward the supply reservoir. The outputs from both heads are combined in the reference manifold assembly to produce a continuous solvent delivery.

During normal operation, the solvent from the reference manifold as­sembly flows through the high-pressure filter. The filter smoothes the minor solvent flow fluctuations. In addition, this filter pro­vides sufficient system capacity to minimize pressure upsets during manual injection.

Solvent, after passing through the high-pressure filter, passes through the transducer assembly to the pump output connection of the Model 6000A. The transducer assembly contains a flow-through Bourdon­type pressure sensor which detects changes in solvent pressure and is monitored by the electronic control assembly. Several alternate sol­vent connections are provided in the Model 6000A. A control of the inlet manifold assembly enables a system to operate in recycle, col­lect, and waste modes by simply turning a knob. A drawoff port located on the inlet manifold assembly facilitates manual drawoff of the solvent. In addition, a solvent select valve is also located on the inlet manifold assembly which enables the user to select from one of the three solvents by the turn of a knob.

A reference port on the reference manifold assembly is controlled by the reference valve. It provides a solvent reference for a refrac­tive index detector (when used) and a means to fast flush the Model 6000A system when the valve is opened. In addition, a gradient connection port is also located on the reference manifold assembly. It enables the reference valve to be used as a mixer manifold when the Model 6000A is used for gradient operations.

ELECTRONIC CONTROL

Automatic control of the solvent flow rate is accomplished by the Electronics Control Unit. The flow rate is determined by the speed of the electronically-powered motor which drives both pump head assemblies. The motor speed is accurately controlled by the setting of a digital flow switch on the Electronics Unit front panel. The higher the switch setting, the faster the motor speed and the higher the resultant flow rate.

The output of the transducer assembly is fed back to the Electronics Unit which performs the following:

1.         Changes current of the drive motor, as pressure changes, to minimize heat at low pressure operation.

2.         Compensates for solvent compressibility and system elasticity to maintain a constant flow rate.

3.         Halts Model 6000A Operation if the pressure exceeds the preset pressure limit.

4.          Provides panel meter indication of solvent pressure.

5.         Provides an electrical output (via terminal jacks) of solvent pressure for recording by an external device, to aid in monitoring Model 6000A operation and troubelshooting.

Product group: HPLC-Pumps (isocratic)

We can't find products matching the selection.
Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Smart Deals Smart Deals
Labprocure