Waters UV/VIS-Detector 486. YoC: 1999.
siehe Storeview
More Information
Objektnummer B00012825
ID-number 012825
Object name Waters 486
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Waters

Modell:                         486

Kommentar:     Dokumente engl.

 

 

 

 

The Waters 486 Tunable Absorbance Detector (the Waters 486) is a single-channel tunable ultraviolet/visible (UV/VIS) detector designed for high performance liquid chromatography (HPLC) applications.

 

The Waters 486 can operate as a stand-alone unit (with a chart recorder) or with other Waters system modules, such as the Waters 860 Networking Computer System, the Waters 600E Multisolvent Delivery System, or the Waters 745/745B or 746 Integrators.

 

 

Wavelength range        The 486 provides a usable light intensity over the wavelength range

and sensitivity                of 190-600 nanometers (nm), although its primary use is in the   ultraviolet wavelength range between 190 and 380 nanometers. The       maximum sensitivity of the instrument is 0.001 absorbance units full                                       scale (AUFS).

 

Features                        The Waters 486 offers the following features:

• Easy to use operator interface

• Self-calibration to ensure wavelength accuracy

• Battery backup to retain parameter settings when the detector is powered down or during power interruptions

• A deuterium arc lamp

• The patented Taper-Gell© flow cell design which reduces refractive index interference with the absorbance signal

• Optional cells:

• Non-metallic

• Semi-prep

• Microbore

• High Pressure (A cell optimized for operation in LC/MS)

• Lamp shut-off to lengthen usable lamp life

• User selectable chart mark an IV integrator ouput (standard an 10mV)

• Wavelength scanning for determination of optimal wavelength

• Diagnostic routines to verify proper functioning

• A modular design for easy servicing

 

Operational Specifications

 

Wavelength range                   190 to 600 nm

(single, fixed wavelength)

Wavelength accuracy             ± 2 nm

Wavelength repeatability         ± 0.25 nm

Noise                                       ±1.0 x 10 -5 AU, 1 second filter setting, 210 to 280 nm) dry cell

Drift                                          1.0 x 10 -4 AU per °C (after warm-up)

                                               1.0 x 10 -4 AU per hour (after warm-up)

Sensitivity Setting Range        0.001 to 2.0 AUFS (under software control)

Filter Setting Range                0.1 to 5.0 seconds (under software control)

Bandwith                                 8 nm

 

Optical Component Specifications

Lamp Source                          Deuterium arc lamp

Flowcell                                   Dual beam Taper-Cell ® design

Path length                              10 mm (standard, analytical)

Cell volume                             8 µL (standard, analytical)

Pressure limit                          1000 psi

Materials                                  316 stainless steel, Dynasil ® ,

                                               Suprasil II ® , Teflon ®

 

Environmental Specifications

Operating temperature            15 to 32.2°C

Operating humidity                  20 to 80%, non-condensing

Shipping and storage              -40° to 65°C

temperature

Shipping and storage              20 to 80% non-condensing

humidity

 

Dimensions

Height                                      9.2 inches (24 cm)

Length                                     21.5 inches (54.5 cm)

Width                                       11.2 inches (28.5 cm)

Weight                                     38 pounds (17.5 kg)

 

Electrical Specifications

Line Frequency                       50 Hz, 47 -53 Hz

                                               60 Hz, 57 - 63 Hz

 

Fuse Ratings                           1.5A, 100/120 VAC

                                               0.75A, 220/240 VAC

 

Power Consumption               100 VA (Nominal)

 

DC Power Supply                   +5VDC at 2.2 A (Power limited at 11 W) ±15VDC at 300 mA

 

Lamp Power Supply                309 mA Regulated Constant

                                               Current (Fused at 3/8 A)

                                               3.0 VAC Filament Heater

                                               (unregulated) (Fused at 6 1/4 A)

                                               500 VDC Arc Strike (nominal)

 


Instrument Operating Voltages

                                               Voltage                          Setting Range

                                               100 Vac                          85 to 110 Vac

                                               120 Vac                          102 to 132 Vac

                                               220 Vac                          187 to 242 Vac

                                               240 Vac                          204 to 264 Vac

 

 

Optical Specifications

                                               Monochromator           Seya-Namioka configuration

                                               Grating                           Concave holographic

                                               Optical Bandwidth         8 nm

                                               Lamp Power                  30W

 

 

Optional Flow Cell Specifications

                                 Volume            Path                 Sample                          Reference

                                                         Length            In              Out                In              Out

Analytical Cell                  8 µl             10 mm             0.009"       0.009"            0.009"       0.009"

Semi-Prep Cell             2.5 µl               3 mm             0.040"       0.040"            0.009"       0.009"

Microbore Cell              2.5 µl               3 mm             0.005"       0.005"            0.009"       0.009"

Non-metallic Cell             8 µl             10 mm             0.010"       0.010"            0.020"       0.020"

Mass Spec Cell               8 µl             10 mm             0.009"       0.009"            0.009"       0.009"

 

Product group: HPLC-Detectors (UV/VIS)