Waters Fluorescence detector 474. Flowcell 16µl. Max pressure 1000 kPa.
siehe Storeview
More Information
Objektnummer B00014811
ID-number 014811
Object name Waters 474
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Firma:                   Waters

Modell:                474

Kommentar:        Dokumente engl.

The Waters 474 Scanning Fluorescence Detector is a high-performance unit that provides a high level of sensitivity for spectrofluorometric analysis.

Features

The Waters 474 Scanning Fluorescence Detector includes:

•     An optical design that maximizes sensitivity

•     Microprocessor control for greater versatility and reliability

•     An emission wavelength sweep function so you can obtain an emission spectrum

•     An excitation wavelength sweep function so you can obtain an excitation spectrum

•     An automatic second-order filter to enhance applications in the visible wavelength range

•     Optional optical filters that can be installed on the flow cell for specialized measurements

•     Quartz flow cell or cuvette cell, permitting measurement of ultraviolet fluorescence

•     Nine-stage photomultiplier tube for amplifying the emission radiation

•     Photodetector to compensate for excitation fluctuations throughout a scan

•     An RS-232 port to allow connectivity to the Millennium 32 data system

There are three critical optical design features in the 474 detector-.

•     A highly energy-efficient optics system that does not use lenses, minimizing reflection loss

•     An optics system that uses holographic concave diffraction gratings and aspherical mirrors to provide highly efficient monochromators in a Compact package

•     A 150 VV Xenon lamp that provides greater light energy for excitation

There are five critical microprocessor-based features:

•     Operating parameters that are set using the keypad

•     A multi-line liquid crystal display (LCD) that provides Information on the status of the 474 detector

•     Self-diagnostic messages that are displayed on the LCD

•     Digital processing that controls the entire signal processing system, assuring higher reliability and operational stability

•     An auto-zero feature that provides a wide range of Offset adjustment for the analog output


Operational Specifications

Monochromator                       Holographic concave diffraction grating (for both excitation and emission)

Light source                            150 W Xenon lamp

Wavelength range                              200 to 700 nm (for excitation and emission). Can be set from 0 to 900

Spectrum band width              Excitation: 18 nm

                                               Emission: 10, 18, or 40 nm (set an keypad)

Wavelength accuracy             ±2 nm

Wavelength repeatability         ±0.3 nm

Detector                                  Excitation-. Photodiode

                                               Emission-. Photomultiplier tube

Second order filter                   Automatically inserted into light path when Ex > 400 nm

Flow cell                                  16 µL (standard) or 5 µL

Maximum flow cell pressure   16 µL: 145 psi (10 bar)

                                               5 µL: 500 psi (34.5 bar)

Wetted surfaces                     Synthetic silica, fluororesin, PEEK, stainless steel
SXS-316

Sensitivity                                S/N for the Raman peak of water is 320 or above, where Ex λ = 350 nm and time constant is 1.5 sec, 16 µL cell (Instruments shipped prior to June 1997, S/N for the Raman peak of water is 200 or above)

Attenuation range (Recorder output) Ten steps, including 1, 2, 4, 8, 16, 32, 64, 128, 256, S

Gain range                               1, 10, 100, 1000

Response                                Fast, Standard, Slow, and digital filter

Signal processing                   Digital processing by A/D and D/A converters (with surrounding temperature compensation circuits)

Outputs                                   •     Recorder: 10 mV full-scale (can be inverted)

                                               •     Integrator: 1 V full-scale

                                               •     Marker output

                                               •     Leak output

Inputs                                       •     Marker input

                                               •     Auto Zero input

                                               •     Program reset

Program functions                  Time program with following variables:

                                               •     Wavelength change (excitation and emission)

                                               •     Gain

                                               •     Attenuation

                                               •     Wavelength scan

                                               •     Ex, Em Spectra

Wavelength scan functions    Manual and time program parameters:

                                               •     Time

                                               •     Interval

                                               •     Amplitude

                                               •     Memory location

                                               •     Ex, Em Spectra

Spectrum storage                   Ten locations for both emission and excitation spectra

Self-test diagnostics               •     Memory (ROM and RAM)

                                               •     DC power

                                               •     Excitation energy decrease

                                               •     Leak in cell

                                               •     Lamp use time

Lamp use timer                       Internat timer for accumulating the total hours an the
Xenon Iamp

Dimensions                            Width. 11.81 inches (300 mm)

                                               Height: 5.90 inches (150 mm)

                                               Depth: 18.11 inches (460 mm)

Weight                                     41.8 pounds (19 kg)

Power requirement                 115 VAC (90 to 132 V), 50/60 Hz

                                               230 VAC (187 to 264 V), 50/60 Hz

Power consumption                300 W maximum

Ambient temperature              10 °C to 32 °C (50 °F to 90 °F) operation

                                               10 °C to 60 °C (50 °F to 140 °F) storage

Relative humidity                     20 to 80%, non-condensing