Sold

Varian VK 7030

ID-number: 020191
Status: Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
Varian Dissolution apparatus VK 7030. 5-40°C. 115/230 V. 50/60 Hz. 15 A. Bath with peristaltic pump. YoC 2008
Quotation
siehe Storeview
More Information
Objektnummer B00020191
ID-number 020191
Object name Varian VK 7030
Status Stock unit

Product group: Digestion systems

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer:       Varian

model:                   VK 7030

annotation:           Dokumente engl.

 

 

 

 

 

 

 

 

 

The VK 7030 is an automation-friendly instrument with an easy-to-use design. It offers direct access for easy cleaning, excellent visibility and advanced temperature control.

 

 

Variable                       Specification

 

Condition                    Operating but not necessarily meeting performance specifications

 

Altitude                         0 – 2000 m (0-6562 ft.)

 

Temperature              5 to 40°C

 

Humidity

(non-condensing)        Not more than 80% RH

 

Voltage

Requirements             115 V/60 Hz

230 V/50 Hz

 

Current

Requirements             115 V – 15.0 Amp

                                   230 V – 15.0 Amp

 

Spindle Speed

range                          10 - 250 RPM

 

Spindle speed:

accuracy                    ± 1% over 25 RPM; ± 2% 10-25 RPM

 

Speed

Selection                     Via front-panel keypad

 

Sampling                     Compatible with VK 8000 (not supplied)

                                   For automated sampling

 

Display                       LCD

 

Spindle material          Stainless steel

 

Drive unit                     Motor drive, controllable from front-panel touch keys

 

Keypad                        Sealed switch-type with alphanumeric menu keys

 

Fuse

Requirements             115 V-Internal circuit breaker, 15 Amp

                                   230 V-Internal circuit breaker, 15 Amp

 

Dimensions                 Height              68.58 cm (27 in.)

                                   Width               67.31 cm (26.5 in.)

                                   Depth               76.2 cm (30 in.)

 

Machine weight           83.5 kg (185 lb), with vessels and paddles

 

Printer                          Impact

 

 

 

 

  • Direct Vessel Heating (DVH) technology precisely controls the heating of dissolution media and replaces traditional water baths.

 

  • Innovative V-shaped design and vessels offer a direct view of the six sample vessels at all times

 

  • Optional control of individual spindles is ideal for automated methods

 

 

 

 

Designed for use with USP Apparatus 1 and 2, the VK 7030 replaces a traditional water bath with patented DVH technology. Water baths and circulating pumps are now a thing of the past. The result is a fast startup, excellent temperature uniformity, and the easiest maintenance of any dissolution tester available today.

 

Our DVH technology meets USP, EP, and JP requirements for heating. The dual-zone DVH heater element uses copper wire captured between two layers of thin-film polyester, which is then attached to the glass vessel using high-temperature clear adhesive. The heater element withstands vigorous cleaning in industrial-grade washers up to 65°C.

 

The VK 7030 also features an alpha-numeric keypad, digital communication, and programmability. The configuration includes six or eight spindles and can be equipped with paddles or baskets.

 

 

Designed for Automation

  • Standard on all units, Dosage Delivery Module (DDM) can be programmed automatically, simultaneously, or sequentially to deliver dosages to vessels with instant or delayed starts. This feature replaces the need for manual dropping and allows for unattended test starts.
  • Also standard on all units is the AutoTemp in-vessel temperature monitoring system that automatically measures and records individual vessel temperatures.
  • Independent cannulas allow staggered drops and sampling without disrupting vessel hydrodynamics, while ensuring an accurate sampling position based on the specified volume of media used. The independent sampling cannulas can be lowered individually in a sequential run or in unison during a simultaneous sampling gprogram .
  • Optional AutoSpindle control (clutches) allows for sequential delivery of dosage into non-rotating media. These electric clutches can stop and start each spindle independently.
  • Flexible integration with VK 8000 Dissolution Sampling Station. Easily automated for online UV analysis and Fiber Optics.
  • Built-in security features within the software allow administrator and user functionality. Methods require a user name and password. Stores up to 10 users with unique passwords.
  • Large front-panel display provides full information on spindle speed, elapsed time, temperature, and more. Two character sizes are available: standard size for programming and a larger size for better visibility when monitoring operating parameters.

 

 

 

Direct Vessel Heating

  • DVH TruCenter TM vessels ensure perfect centering and alignment every time.
  • Environmental chambers isolate vessels from laboratory conditions and contain media in the event of vessel breakage.
  • Dual-zoned heating elements allow precise control of media from 500 mL to 1000 mL .
  • DVH incorporates two temperature control mechanisms. The first monitors and controls temperature while the second measures and records temperature.

 

 

 

Motorized Drive Unit

  • Unit lifts at the touch of a button.
  • Motorized drive unit slides from the front to the rear of the tester providing complete access to the vessels for removal and cleaning.
  • Drive unit sits low and close to the vessels. Less overhead clearance is required.
  • Lower profile allows for shorter shafts, reducing the potential for wobble.

 

 

 

Easy Access, Easy Use

  • Access to the six perimeter vessels for sampling is simple. An easy-to-use sampling cannula is included to reach interior vessels.
  • Vessel evaporation covers automatically lower into position as the drive unit is lowered and are easily removed for cleaning.
  • Hinged-top cover offers convenient access to the system mechanics.
  • Vessel plate is made of chemically resistant Corian® for durability and easy clean up.
Part of labexchange logo