Varian SpectrAA 400 P
Objektnummer | B00016258 |
---|---|
ID-number | 016258 |
Object name | Varian SpectrAA 400 P |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Kommentar: Dokumente engl. (IDNR.: 09566)
VARIAN SPECTRAA-400P DOUBLE-BEAM ATOMIC ABSORPTION SPECTROMETER WITH EMISSION CAPABILITY.
Comprises spectrometer module and IBM PS/2 Model 30.
Optics: All reflective for constant focus, hard dielectric coated for high reflectivity and increased resistance to corrosion, sealed against dust and vapor.
Monochromator: Czerny-Turner monochromator with 330mn focal length. Holographic diffraction grating of 1800 lines/mm, blazed at 240 nm.
Wavelength range 180-900 nm, automatic drive under computer control, automatic peaking.
Full height slits with 0.1, 0.2, 0.5 and 1.0 nm spectral bandwidth, reduced height slits with 0.2, 0.5 and 1.0 nm spectral bandwidth, autmatic slit selection. Selected photomultiplier covering fult wavelength range.
Eight-lamp turret: Computer-controlled turret mounts 8 hollow cathode lamps. Provides automatic recognition and selection of coded SpectrAA lamps. In a multi-element sequence, the next lamp in the sequence is warmed up at its operating current.
Programmable flame control. Uses data station for entry, display and storage of flame type and gas flows. Push-button flame ignition and extinction.
Interlocks monitor: oxidant pressure, reservoir pressure, mains voltage, gas flows, burner type, flame condition, spray-chamber bungs, flame shield and liquid trap level.
Flame atomizer: Hi-vac nebulizer with plantinum-iridium capillary and tantalum venturi, interlocked nebulizer bung with externally adjustable glass impact bead.
Inert polypropylene spraychamber with interlocked pressure relief bung at rear, integrat polypropylene liquid trap with liquid level interlock. Titanium burner head. Burner, spraychamber and liquid trap may be removed for maintenance by releasing two screws.
Sensitivity greater than 0.5 absorbance for 5 ug/ml copper using air-acetylene burner.
Background correction: Pre-aligned deuterium lamp for background correction between 190 nm and approx. 425 nm. Correction to 2 absorbance. High-Speed electronic modulation for correction of transient signals.
lncludes IBM PS/2 Model 30/286
Controls complete AA + accessory.
Incorporated 28.5 cm video display unit: 1 MB RAM,
one double-sided, double density disk drive with 1,4 MB storage; one 30 MB hard disk; full alphanumeric keyboard plus 12 special function keys, separate numeric and cursor keypads; Centronics interface for connection to printer. (IBM DOS 3.30). Enhanced Graphics Adapter (EGA) Card with EGA Colour Monitor.
Software for flame and furnace operation. Utilities and communication software.
PSC-56 PROGRAMMABLE SAMPLE CHANGER
Automatically present samples to SpectrAA series flame atomic absorption spectrometers or VGA-76 vapor generation accessory. Carrousel holds 5 standards and 67 samples in test tubes plus rinse, blank and restope beakers. The SpectrAA keyboard, video display unit and disk drive are used for entry, display and storage of PSC-56 parameters. Programmable parameters are numbers of standards, first and last sample, rinse rate, rinse time, delay time, dip time (for micro sampling), number of replicates, recalibration rate and reslope rate.
OPTION
GTA-96 GRAPHITE TUBE ATOMIZER WITH SAMPLE DISPENSER
220 V, 50 Hz.
DISPLAY
Tables for temperature and sample dispenser programming, and graphical display of temperature/time profile, background absorbance and background corrected absorbance are provided.
TEMPERATURE RANGE
40 to 3000 degrees C, up to 20 temperature steps, programmable heating rate to 2000 C/sec.
GASES
Inert gas (usually ergon or nitrogen) and alternate gas. Flow setectable.
HEATED INJECTION
Programmable in the range of 40°C to 150°C.-Programnable injection rate.
PROGRAMMABLE SAMPLE DISPENSER
Dispenses blank, standard (5) and samples (45) together with chemical modifier solution if required. Modifier may be injected and dried prior to sample injection. Automatically prepares calibration standards or standard addition on samples using stock solution.
MULTIPLE INJECTION
Up to 99 injections may be made, drying (and ashing if required) between each injection, before atomizing the sample.
CALIBRATION
Normal or standard addition or bracketing standards. Programmable reslope and recalibration rates. Up to five standards can be used.
MODEL VGA-76 VAPOR GENERATION ACCESSORY
Supplied complete with quartz absorption cell with holder, gas liquid separator, reagent containers, all tubings, hoses and connectors, spare kit of tubing and connectors.