Varian SpectrAA 220

ID-number: 011119
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Varian Flame AAS SpectrAA 220 FS. Able to measure 4 elements paralel. Software SpectrAA 4.0
siehe Storeview
More Information
Objektnummer B00011119
ID-number 011119
Object name Varian SpectrAA 220
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Varian

Modell:            SpectrAA 220

Kommentar:   Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.

SpectrAA-50/55/110/220 instrument dimensions

Spectrometer System unit                      Width               Depth              Height        Weight

SpectrAA-50/55/110/220                            790 mm           585 mm           575 mm      46 kg

instrument only                                           (31")                 (23")                 (22.5")         (101 Ib)

SPS-5 Sample Preparation System          525 mm           610 mm           570 mm      19 kg

                                                                  (21")                 (24.4")              (22.8")         (42 Ib)

SIPS 10/20:

Sample Introduction Power Unit                225 mm           105 mm           385 mm      4.5 kg

                                                                  (9 ")                  (4 ")                  (15.5 ")        (10 Ib)

Sample Introduction Pump Unit                 280 mm           265 mm           220 mm      4.5 kg

                                                                  (11 ")                (10.5 ")             (9 ")             (10 Ib)

System unit                                               Required supply voltage                        Rating

SpectrAA 50/55/110/220                            100, 120, 220 or 240 VAC ±10%               170 VA         230 VAC +14% -6%

                                                                  230 VAC +6% -14%

                                                                  50 or 60 Hz ±1 Hz

SIPS 10/20                                                 90-264 VAC                                                55 VA

SPS-5 Autosampler                                   100, 120, 220 or 240 VAC ±10 %              80 VA

                                                                  230 VAC +14% -6%,

                                                                  230 VAC +6% -14%

                                                                  50 or 60 Hz ±1 Hz

Sample Introduction Pump System (SIPS) for Varian AA instruments

The Sample Introduction Pump System (SIPS) is an innovative sample introduction and dilution system for flame AA that eliminates the task of multiple standard preparation and provides fast, accurate on-line dilution of over-range samples. SIPS is available in 2 versions:

·        The single pump SIPS 10

·        The dual pump SIPS 20 (shown at right)

The SIPS 10 or 20 can be used on all PC-controlled Varian AA instruments in the current range. The SpectrAA 50 and 55 without PC can be fitted with the SIPS 10 only.

Features

·          No tedious, multiple standard preparation. Performs online multi point calibration from a single standard

·          Fast, online dilution of over range samples

·          No costly, time consuming manual dilution and re-analysis

·          Enhances accuracy and precision with < 2% error - no more dilution errors

GTA

Specifications

Environmental conditions

Your accessory is designed for indoor use only.

Condition

Altitude

Temp t (°C)

Humidity (%RH)

non-condensing

Non-operating (storage)

0-2133 m

(0-7000')

5-45

20-80

Not operating but meeting dielectric sea level strength tests

sea level

5-40

90-95

Operating, but not

necessarily meeting performance specifications

0-2000 m

(0-6562')

5-31

31-40

≤80

≤{80-3.33(t-31)}

Operating within performance specifications

0-853 m

(0-2800')

853-2133 m

(2800-7000')

10-35

10-25

8-80

8-80

Power

Voltage 208, 220, or 240 volts AC ± 10%, 230 +140/o -6% volts AC, 230 +60/o -140/o volts AC.

Frequency 50-60 Hz ±1 Hz

Gas supplies

An inert gas is always needed at the normal gas inlet to the GTA. This gas is used to shroud the hot graphite components and prevent oxidation.

The preferred gas for the normal gas inlet is argon. Nitrogen is an acceptable lower cost alternative but furnace performance may be degraded for some elements and tube lifetime may be reduced. The argon or nitrogen used must be at least 99.99% pure.

Nitrogen or air may be used at the alternate gas inlet. A choice is made on the basis of the analytical technique for the sample.

Water supply

Maximum temperature                               40°C (104 °F)

Recommended temp. range                      18-25°C (64-70 °F)

Note Water temperature should be set above the dew point to avoid condensation forming on the workhead surfaces.

Minimum flow rate required                        1.5 L/min at 180 kPa (27 psi)

Typical flow rate at recommended            1.5-2.0 L/min

pressure range

Product group: Atomic absorption spectrometers (flame)

We can't find products matching the selection.
Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Smart Deals Smart Deals
Labprocure