Sold

Varian CP-3800

ID-number: 021211
Status: Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
Varian GC/MS Saturn CP-3800. MS Ion trap detector Saturn 2000. Autosampler CP-8400. Turbopump. Capillary Injector. PTV. PC with GC/MS-Workstation , Version 5.4. YoC 2000
Quotation
siehe Storeview
More Information
Objektnummer B00021211
ID-number 021211
Object name Varian CP-3800
Status Stock unit

Product group: GC / MS

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Varian

Modell:            CP 3800

Kommentar:   Dokumente engl.

 

 

 

 

Outstanding Flexibility with Proven Performance

The Varian CP-3800 GG for any application

 

Flexible platform – single, dual, or three-channel configurations for maximum productivity.

 

Easy upgrades – quickly add additional capabilities as your requirements change.

 

Simplified PC control – password security, Star Chromatography Workstation Quick Start Applications, and Custom Report. Writer templates streamline operation

 

The Varian CP-3800 GC meets all your analytical requirements with practical solutions for simple and complex applications.

 

In a standard configuration, the CP-3800 accommodates up to three injectors and three detectors, all operating simultaneously. In addition, the CP-3800 is easily configured to perform on-line analyses for monitoring critical gas and liquid process streams.

 

The CP-3800's flexible platform lets you start with a basic configuration and add a wide variety of options in the field. Options include additional channels, gas and liquid sampling valves, and external sampling devices. Future upgrades guarantee that you can meet changing requirements at a moment's notice.

 

Star Chromatography Workstation combined with Quick Start Applications provide a powerful yet simple interface for controlling the CP-3800 GC. Routine applications can be launched from the desktop with minimal data entry. Reports specific to your application are easily created with Star Custom Report Writer. Report generation can be automated for around-the-clock monitoring.

The CP-3800 GC from Varian-unlimited possibilities!

 

 

• Simple and easy to operate

• Flexible custom configurations

• Stand-alone, PC, and client/server control

 

 

 

Injectors

•            CP-1177 Split/Splitless Injector with optimized Split vent design

•            1079 PTV (Programmable Temperature Vaporizing) injector for cold on-column, LVI (Large Volume Injection), and solid sample introduction with ChromatoProbe

•            1093 SPI (Septum-Equipped Programmable Injector) for high temperature capillary column applications

•            1041 On-Column/Packed Injector for 0.53 mm ID capillary and packed column applications

•            1061 Flash Injector for simplified direct injections

•            Valve Systems for gas and high pressure liquid samples

•            Integrated SPT (Sample Preconcentration Trap) for concentrating gas samples

Column oven

•            Spacious oven accommodates three or more columns

•            Varian Quick Connects provide easy column Installation

•            Rapid oven cool down increases sample throughput

•            Cryogenic cooling extends application range

Detectors

•            Flame lonization (FID) with a patented, ceramic flame tip for ultimate peak shape and sensitivity

•            Thermal Conductivity (TCD) with automatic filament protection for lowest maintenance costs

•            Electron Capture (ECD) for ultra-high sensitivity and selectivity of halogenated compounds

•            Thermionic Specific (TSD) for selective detection of nitrogen/phosphorus compounds

•            Pulsed Flame Photometric (PFPD) for selective detection of sulfur, phosphorus, nitrogen, and 25 additional elements

Galaxie Chromatography Data System

•            Simple Interface for easy method building and data acquisition

•            Password protection eliminates unauthorized data access and method editing

•            Easy for occasional users with customized screens showing just the Information needed

Simpfified user interface

•            Large display with 11 lines and 35 characters/line for easy viewing

•            Easy method navigation for greater productivity

•            Access to all GC parameters for complete method editing and System control

AutoSamplers

•            CP-8400 handles up to 100 samples with liquid, ambient headspace, or optional SPME sampling modes

•            CP-8410 with a fixed Sample trag Supports multiple vial sizes

•            Combi PAL offers maximum flexibility for liquid, heated headspace, and SPME applications

•            Archon with Tekmar Vetocity XPTTm for automated Purge and Trap sampling

 

 

 

 

CP-3800 GC Specifications

Dimensions and Weights

• Size: 53 cm (h) x 66 cm (w) x 56 cm (d)

• Weight: 43 kg

 

Environmental Conditions

• Operating temperatures: 10°C to 40°C

• Operating humidity (relative): 5% to 95%

• Line voltage requirements: 101V, 120V, 230V (±10% nominal)

 

Column Oven

• Dimensions: 28 cm (w) x 20 cm (d) x 28 cm (h)

• Temperature range: arnbient +4 °C to 450 °C

• With liquid N 2 : -99 °C to 450 °C

• VVith liquid CO 2 : -65 °C to 450 °C

• Temperature program ramps/holds: 7/8

§ Maximum temperature ramp rate: 100 °C /min for all voltages

§ Cool down rate: 400 °C to 50 °C in 4.5 minutes

§ Temperature set-point resolution: 1 °C

 

Injector Options

• Maximum injectors: three operating concurrently

• Pneumatics: manual or electronic flow control (EFC)

• Columns: capillary columns standard with optional packed column adapter

• Injectors

• CP-1177 Split/Splitless

• 1079 Programmable Temperature Vaporizing (PTV)

• 1061 Flash Megabore/Packed

• 1041 On- Column Megabore/Packed

CP-1177 Split/Splitless

• Pressure range: 0-100 psi

• Total flow: 500 rrillrnin at 10 psi

• Maximum temperature: 450 °C

• Split range: 1-10,000 (column dependent)

1079 Programmable Temperature Vaporizing (PTV)

• Pressure range: 0-100 psi

• Total flow: 500 mL/min at 10 psi

• Temperature range

• -99 °C to 450 °C liquid N 2

• -65 °C to 450 °C liquid CO 2

• Maximum temperature ramp rate: 180 °C/min

• Temperature ramps: 4

• Split range: 1-10,000 (column dependent)

•     Operational modes

•     Temperature ramped splitless

•     Cold on-column

•     Large Volurne Injection

•     Split and splitless

•     ChromatoProbe solid sample introduction:

optional

1061 Flash Megabore/Packed

• Pressure range: 0-100 psi

• Total Flow:    50 mL/min (Type 3 EFC)

                        500 mL/min (Type 4 EFC)

• Maximum temperature: 450 °C

1041 On-Column Megabore/Packed

• Pressure range: 0-100 psi

• Total Flow:     50 mL/min (Type 3 EFC)

                        500 mL/min (Type 4 EFC)

• Maximum temperature: 450 °C

 

Quick-Switch Valve Option

• Instantly switch between injectors/columns and cletectors

• Configurations: automated or manual, factory or field installed

 

Detector Options

• Maximum detectors: three operating concurrently

• Pneumatics: manual or electronic flow control (EFC)

• Columns: capillary columns standard with optional packed column adapter

• Detectors

•     Flame lonization Detector (FID)

•     Thermal Conductivity Detector (TCD)

•     Electron Capture Detector (ECD)

•     Thermionic Specific Detector (TSD or NPD)

•     Pulsed Flame Photometrie Detector (PFPD)

FID

• Maximum temperature: 450 °C

• Detectivity: 2 pg C/see

• Linear dynamic range: 10 7

• Patented ceramic -Flame tip: standard

• Flame-out detection/auto re-ignition: standard

TCD

• Maximum temperature: 450 °C

• Detectivity: 300 pg/sec (C4)

• Linear dynarnic range: 106

• Filament proteefirm: standard

• Automatic bridge balancing: standard

ECD

• Maximum temperature: 450 °C

• Detectivity: 7 fg/sec Lindane

• Linear dynamic range: 10 4

TSD

• Maximum temperature: 450 °C

• Detectivity:

N: 100 fg N/sec (Azobenzene)

P: 100 fg P/sec (Malathion)

• Maximum temperature: 450 °C

• Linear dynamic range:

N: 10 5

P: 10 4

• Self-aligning bead: standard

PFPD

• Maximum temperature: 450 °C

• Detectivity: using 5/P Photomultiplier Tube

            S: 1 pg S/sec

            P: 100 fg P/sec

            N: 20 pg N/sec

• Linear dynamic range:

S: 10 3
P: 10 4
N: 10 2

Electronic Flow Control: injectors

• Module types: 4 injector-specifie modules

• Accuracy: ± 0.1 psi, 5% full scale flow

• Resolution: 0.1 psi or 0.1 mL/rnin

Electronic Flow Control: Detectors

• Module types: 6 detector-specific modules

• Accuracy: ± 7% set point flow

• Resolution: 1 mL/min

 

Communications

• Three channel analog output time prograrnmable (0-1V or 0-10V): standard

• Three channel digital output and control with TCP/IP Ethernet and LAN connectivity: optional

• Synchronization signals: for 'ready" and 'start" with other devices and data systems

 

Data Handling

• Star Integrator: optional

• Star Workstation (PC) control: optional

• Galaxie Workstation (PC) control: optional

• Galaxie Chromatography Data System (CDS) client/server control: optional

 

Other Specifications

• Powered external events: 7

• LCD display: 11 lines, 35 characters/line

• Maximum stored methods with battery protection: 8

• Internal autosampier control: standard

• On-line hell): standard

• Complete local control: standard

 

Automation Options
CP-8410 Autoinjector

• Sample eapacity: 10 x 2 mL, 6 x 5 mL, and 5 x 10 mL vials

• Dual and duplicate mode: standard Internal standard addition: standard

• Modes of Operation: liquid, standard; ambient headspace, optional; and SPME (Solid Phase Microextraction), optional

• Pre-programmed modes of injection: standard

CP-8400 AutoSampler

• Sample capacity: 100 x 2 mL vials

• Dual and duplicate mode: standard

• Internal standard addition: standard

• Modes of operation: liquid, standard; ambient headspace, optional; and SPME, optional

• Sample heating and cooling: optional

• Pre-programmed müdes of injection: standard

Combi PAL AutoSampler

• Sample trays: two standard and expandable to four

• Tray typcs: 98 x 2 mL vials; 200 x 1 mL vials;
32 x 10 m1120 mL vials; and 96-well plates

• Dual and duplicate mode: standard

• Internal standard addtion: standard

• Modes of Operation: liquid, standard; heated headspace, optional; and SPME, optional

• Sample heating and cooling: standard

• Optional modules: additional sample trays, micro-well plate holders, wach station, SPME fiber bake-out station, dilutor, barcode readers, and flowcell

Part of labexchange logo
Search engine powered by ElasticSuite