Description:
Unicam UV/VIS/NIR-Spectrometer PU 8620. Wavelength 195-1100 nm.With Liquid Cuvette.
Quotation
siehe Storeview
More Information
Objektnummer B00012270
ID-number 012270
Object name Unicam PU 8620
Status Stock unit

Product group: NIR-Spectrometer

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                Unicam

Modell:              PU 8620

Kommentar:      Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.

Principal Design Features

The PU 8620 Series of single beam UV/VIS/ spectrometers has the following major characteristics:

·        Tungsten-halogen and deuterium arc sources an pre-focussed bases

·        Master holographic diffraction grating with 600 lines/mm and blazed at 240mm

·        Silica-coated grating and mirrors

·        Automatic selection of appropriate light source and filters

·        Automatic wavelength calibration

·        Wide-range solid state, diode detector

·        Keyboard entry and display of all parameters

·        Microprocessor control and data handling

·        Results displayed in A, %T, Concentration and Rate (8630 and 8680 versions)

·        Automatic peak-seek with baseline correction

·        Storage of 10 methods in non-volatile memory

·        Self-test of electronics, optical and mechanical functions

·        Result averaging

·        Keyboard selection of measurement delay and repeats

·        Complete remote control via bi-directional RS-232-C link

·        Standard kinematic cell holder for 2 to 50mm cells

·        Accessory set up and control via instrument keyboard

·        Extensive range of accessories

Specifications

Wavelength range:                       8620/8630: 195-1100nm

Wavelength setting speed           100nm/s

Bandwidth                                    8nm

Display ranges   absorbance        -0.300 to 3.000

                          transmission      0.1 to 200.0

                          concentration     -999 to 9999 with adjustable decimal position; automatically                 computed after input of value of factor or standard

                          rate                     0000 to 9999 (8630 and 8680 only)

Test mode                                    checks RAM and ROM memory, displays wavelength drive      and calibration, detector output, etc.; generates test report   an external Printer (if fitted) including instrument and source          ages and character set; generates test ramp (if 8606      Recorder Interface fitted)

Peak seek                                    ±10nm about current wavelength

Method storage                            10 method capacity (including Autocell and Electrocell settings)

Delay times                                  00.00 to 99.59 min.s

Integration (averaging) times       00.00 to 99.59 min.s

Number of cycles (repeats)         1 to 999

Typical Performance

Wavelength accuracy                  within 1 nm

Wavelength reproducibility           within 0.5nm

Photometric accuracy                 within 0.50% of absorbance value or ±0.002A, whichever is greater, relative to standards traceable to National Physical Laboratory standards

Photometric reproducibility          within 0.5% of absorbance value

Photometric noise                        <0.001 A near OA,<0.002A near 2A (peak to peak) at 546nm

Zero drift                                       <0.003 A/hr after warm-up

Stray light                                     <0.05% at 220nm (Nal/D 2 )

                                                    <0.05% at 340nm (NaNO 2 /W)

General Information

Environmental operating ranges

    temperature                             5 to 40°C (IEC 359)

    relative humidity                       10 to 90% (IEC 359)

Sample compartment

    dimensions                              88 x 240 x 120mm

    tubing routes                            access in front, base and aperture in hinged lid

Dimensions (mm)                        590 (wide) x 374 (deep) x 278 (high)

Weight                                          19.3kg

Radio Interference                       conforms to BS800:1977 (EEC Council Directive 76/889/EEC), CISPR14

Voltage                                         110/120/220/240V ± 10%

Frequency                                    50/60 Hz

Power                                           140 VA (max)

Electrical Safety Class:              

This apparatus has been desigend and tested in accordiance with Safety Class 1 requirements of IEC Publication No. 348, Safety Requirements for Electronic and Measuring Apparatus and has been supplied in a safe condition.