Archive

Thermo Finnigan Trace DSQ

ID-number: 018281
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Thermo Finnigan GC/MS System Trace DSQ.EI. CI. Autosampler AI/AS, version 1.4 SR1. DSQ, version 1.4.1. SP7. Trace GC 2000, version 1.4. SR1. Edwards vacuum pump 3. Software Xcalibur 1.4 SR1 for control and evaluation. System Win2000. Maintenance agreement until the closure of the system end 2009. YoC 2003
siehe Storeview
More Information
Objektnummer B00018281
ID-number 018281
Object name Thermo Finnigan Trace DSQ
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Finnigan

Modell:            Trace DSQ

Kommentar:    Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

TRACE DSQ Features

•            Mass range of 1-1050 amu

•            Scan speeds up to 10,000 amu/sec (profile and centroid)

•            Curved pre-filter for noise reduction

•            ±10 kV conversion dynode for better performance

•            Wide spectral/quantitative dynamic range

•            Removable ion volumes for EI and CI

•            Combination ion volume for automated EI/CI Operation

•            Powerful Xcalibur® data system

Analytical versatility

•            EI mode for identifying unknowns - library search Information

•            PCI for molecular weight confirmation

•            NCI for ultimate sensitivity and selectivity

•            Simultaneous Full Scan and SIM in a single analysis

•            PPINICI - hardware/software Option wich

alternating PCl/NCI scans for sample screening

Expanded capabilities

•            Vacuum interlock

•            Liquid and headspace autosamplers

•            DEP/DIP solids probes

•            High-capacity differential pumping system

•            Two positions available for traditional GC detectors

Specifications

Features

Options

Certification: Electromagnetic Compatibility

(EMC) and FCC Clans A

Electron lonization (EI) with

Exchangeable Ion Volumen

Autosamplers: Liquid or

Headspace

Dimensions: l 68 cm x w 33 cm x h 44 cm

70 L/s Turbomolecular Pump

Chemical lonization (CI)

Space Requirements: 2 m (6 ft)

RF-Only Curved Quadrupole

Prefilter

Data System Software

Options: NIST, Wiley, or

Pfleger-Maurer-Weber

Library, EnviroLab Forms,

ToxLab 2.0

Weight: 45 kg (98 lbs)

Ion Source Temperature up to

300 °C and GC Interface

Temperature up to 350 °C

Direct Proben System (DIP or DEP)

Power: 120 V ac or 230 V ac, 50/60 Hz

Mass Range 1 –1050 u (Unit Mass Resolution)

Inlet valve

Temperature: 15-31 °C (59-88 °F)

Scan Rate up to 10,000 u/s

PPINICI (Pulsed Positive Ion,

Negative Ion CI)

Humidity: 40-80%

Full Scan, SIM, and Simultaneous

Full Scan/SIM

Programmable Temperature

Vaporizer or Cold On‑

Column Injector

Post-Acceleration ±10 kV

Conversion Dynode

Turbomolecular Pumps:

250 L/s or 200/200 L/s Split‑Flow

Xcalibur Ver. 1.4 Running Under

Microsoft® Windows@ XP

Professional with Office XP

Ion Gauge with internal

vacuum protection safety

Product group: GC / MS

We can't find products matching the selection.