Thermo Electron Omni slide
Objektnummer | B00014386 |
---|---|
ID-number | 014386 |
Object name | Thermo Electron Omni slide |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Thermo Electron
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
Introduction
The OmniSlide Thermal Cycler can be programmed to perform all types of temperature-controlled reactions on slides, from simple one step incubations, to complex multi-step temperature cycling protocols.
The OmniSlide Thermal Cycler Controller stores up to 18 programs; additional programs (up to 36) may be stored on Data Cards by individual users. Programming and operation are simple to perform, using the combination of user-friendly screens and operating keys. During programmed operation the display screens provide comprehensive Information regarding sample temperature, number of cycles completed, estimated time for completion, etc.
There are two options for control of sample temperature on slides using the OmniSlide Thermal Cycler:
Block Control
Simply controls the temperature of the block, with reference to the thermistors mounted on the lower surface of the block.
Simulated Slide Control
An advanced method of temperature control designed to give accurate temperatures at the upper surface of slides. Typically, when slides are heated on a block, the temperature at the surface of the block is as muck as 3°C higher than the temperature at the surface of the slide. The Simulated Slide Control algorithm compensates for hegt losses from the surface of the slide, so that the programmed temperature is the temperature achieved in samples mounted on the surface of the slides. Furthermore, the approach to temperature is accelerated by precise overshoots in the block temperature.
Two additional software features control the rate of change of temperature and the length of programmed steps with successive cycles:
Temperature Ramping
The temperature ramping Option precisely controls the rate of change of sample temperature (degrees centigrade per second). The maximum setting for the ramp rate with the OmniSlide Thermal Cycler is 0.5°C/ second, which is the default ramp rate. Unless the ramp rate is adjusted then the rate of change of temperature will be fixed at 0.5°C/second that ensures consistent performance from one unit to another. In some instances, however, it may be advantageous to limit the rate of change of temperature, for example, to allow limited extension of short or degenerste primers between primer annealing and DNA synthesis steps to stabilise the primer and template duplex in primer extension reactions. In this case a lower ramp rate (adjustable from 0.1-0.5'/second) should be selected.
Time Increment
This feature enables the time interval of a specified programmed step to be increased with successive temperature cycles. For example, if a time increment of 10 seconds is entered with a step time of 60 seconds, then the incubation times will be 60,70,80,90... etc. seconds.
Temperature accuracy and uniformity across the block, particularly during rapid temperature cycling operations, haue been of paramount importance during the design and development of the OmniSlide. Every machine is calibrated using miniature thermistor probes attached to microscope slides at several block positions simultaneously to ensure that the required temperatures and incubation times are achieved homogeneously in all samples.
Specifications
Thermal Cycler Specifications
Ingress Protection Rating IP20
Standard Accessories Open Humidity Chamber
Slide Rack
Data Card
Temperature
Temperature Range Ambient +15°C for cycling
Ambient + 5°C for incubations
Temperature Control
Accuracy ± 1 °C
Display Resolution 0.1 °C
Block Uniformity ±1.25°C
Temp. Control Options Block Control
Simulated Slide Control
Blocks
Block Component Epoxy/Polyester Povvder Coating
Block Capacity 20 slides (75mm x 25mm x 1 mm)
Programming
Number of Programs on Controller 18
Number of Programs on Data Card 36 Max.
Number of Program Stages 10 Max.
Number of Steps per Stage 10
Max. Programmed Dwell Time 9 hrs 59 mins 59 secs
Temperature Ramping 0.1 to 0.5°C/sec
Time Increment 1 sec - 59 mins 59 sec
Auto Restart Facility Yes
Run End Time Calculation Yes
Dimensions
Width 380mm
Depth 670mm
Height 170mm
Weight 19.8 kg
Equipment Rating
Supply Voltage Range 220/240V on 240V setting
110/120V on 110V setting
Supply Frequency Range 50-60Hz
Power Rating 950W
Fuse Rating 2 fuses of 5A (T) HBC for 220/240V regions
2 fuses of 10A (T) HBC for 110/120V regions
Environmental Operating Conditions
Ambient Operating Temperatures 5°C-40°C
NOTE: When removing the OmniSlide Thermal Cycler from a cold room it should first be equilibrated for 2-3 hours to avoid condensation.
Conforms to IEC1010-1 pollution degree level 2.
Conforms to Electrical Safety requirements described in IEC1010-1.