Archive

Thermo Electron Konelab 20i

ID-number: 015881
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Thermo Electron Clinical-chemical Analyser Konelab 20i. With PC. Workstation. Printer. PC-Table. YoC 2006.
siehe Storeview
More Information
Objektnummer B00015881
ID-number 015881
Object name Thermo Electron Konelab 20i
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Thermo Electron

model :                   Konelab 20i

annotation :           Dokumente engl .

 

 

 

 

 

Throughput

Workload dependent, being in typi­cal routine use up to 200 tests/hour . Time to first result is typically 3 to 12 minutes.

 

Samples

Continuous access to samples with­out interrupting test processing. MAX ON-BOARD CAPACITY:

84 routine samples and 5 STAT sam­ples - 6 segments with 14 positions per segment. Integrated barcode reader and cup/ tube recognition. SAMPLE CUPS AND TUBES:

0.5 ml and 2.0 ml cups, 5 ml and

7 ml tubes, 10 ml tubes with tailored segments.

SAMPLE TYPES: Serum , plasma, urine, CSF.

SAMPLE VOLUMES: Possible range 1-120 µ l ; typically 2-15 µl and 50 µl for Na+ K+ and Cl - tests

 

Reagents

Continuous access to reagents without interrupting test processing. External barcode reader for identifica­tion. Real time reagent status clearly displayed. Up to four reagent addi­tions / test possible.

ON-BOARD STORAGE:

35 positions in the cooled reagent disk.

REAGENT VIALS: 10, 20 and 60 ml REAGENT VOLUMES: 2-250 µl; typi­cally 120 - 200 µl.

 

Cuvettes

Discrete disposable 12-cell cuvette . Continuous access to cuvettes with­out interrupting test processing. ON-BOARD CAPACITY:

600 measurement cells - 50 multicell cuvettes with 12 reaction cells, typi­cally up to up to 3 hours walk-away time.

 

Calibration

Linear, non-linear or bias calibra­tion. Method-dependent use of individual calibrators or automati­cally diluted series from a stock calibrator. Automatic repeat for bias correction available

 

Quality Control

Real time QC with multiple, user-definable Westgard rules. Programmable control interval. QC chart printouts, daily and cumulative reports.

 

Sample and Reagent Dispensing

Externally and internally rinsed single probe dispensers equipped with level sensing.

Dispensing with precision syringes driven by stepping motors. REACTION END VOLUME: 100-250 µl.

SAMPLE CARRY OVER: <1%. REPRODUCIBILITY:

CV less than 2% for sample volumes ≥2 µl and for reagent volumes >5 µl

 

Dilutions

Automatic sample pre-dilution. Automatic post-dilution with both high and low secondary dilution ratios. Ability to add the value of manual pre-dilution for the result calculation.

DILUTION RATIOS: up to 1+120

 

Photometric Measurement

Single channel interference filter photometer with beam splitting reference- 11 fixed filters, others available upon request. SPECTRAL RANGE: 340-800 nm. MEASUREMENT TEMPERATURE: 37°C

MEASUREMENT PRINCIPLES: Colorimetric, turbidimetric . MEASUREMENT MODES:

Kinetic, end-point.

KINETIC MEASUREMENT:

30 sec to 60 min, max 12 points LIGHT SOURCE: Halogen lamp. with linear absorbance range of 0-2.5 A, resolution of 0.001 A and reproducibility of SD≤0.005 A at 2 A.

 

ISE Measurement in the model Konelab 20i

Direct potentiometry . Electrodes for Na+, K+ and Cl -; upon request Li+.

SAMPLES: Serum, plasma and urine.

USABLE RANGE: ( mmol /l)

serum , plasma:

K+ 2.0 - 10

Na+ 100 - 200

Cl-        55 - 150

serum :

Li+ 0.2 - 4.0

urine :

K+ 20 - 200 Na+ 20 – 200

 

Dimensions and Weight Width 80 cm, depth 79 cm, height 115 cm, weight 130 kg. Separate workstation table.

 

Power Requirements

100-240 V ±10%, 50-60 Hz ±5%, 300 W Konelab 20, 350 W Konelab 20i.

 

Distilled Water Consumption Typically <0.5 l/h

On-board storage with no external connections required.

 

 

Product group: Clinical chemistry

We can't find products matching the selection.
Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Smart Deals Smart Deals
Labprocure