Thermo Electron Konelab 20i
Objektnummer | B00015881 |
---|---|
ID-number | 015881 |
Object name | Thermo Electron Konelab 20i |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer : Thermo Electron
model : Konelab 20i
annotation : Dokumente engl .
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
Throughput
Workload dependent, being in typical routine use up to 200 tests/hour . Time to first result is typically 3 to 12 minutes.
Samples
Continuous access to samples without interrupting test processing. MAX ON-BOARD CAPACITY:
84 routine samples and 5 STAT samples - 6 segments with 14 positions per segment. Integrated barcode reader and cup/ tube recognition. SAMPLE CUPS AND TUBES:
0.5 ml and 2.0 ml cups, 5 ml and
7 ml tubes, 10 ml tubes with tailored segments.
SAMPLE TYPES: Serum , plasma, urine, CSF.
SAMPLE VOLUMES: Possible range 1-120 µ l ; typically 2-15 µl and 50 µl for Na+ K+ and Cl - tests
Reagents
Continuous access to reagents without interrupting test processing. External barcode reader for identification. Real time reagent status clearly displayed. Up to four reagent additions / test possible.
ON-BOARD STORAGE:
35 positions in the cooled reagent disk.
REAGENT VIALS: 10, 20 and 60 ml REAGENT VOLUMES: 2-250 µl; typically 120 - 200 µl.
Cuvettes
Discrete disposable 12-cell cuvette . Continuous access to cuvettes without interrupting test processing. ON-BOARD CAPACITY:
600 measurement cells - 50 multicell cuvettes with 12 reaction cells, typically up to up to 3 hours walk-away time.
Calibration
Linear, non-linear or bias calibration. Method-dependent use of individual calibrators or automatically diluted series from a stock calibrator. Automatic repeat for bias correction available
Quality Control
Sample and Reagent Dispensing
Externally and internally rinsed single probe dispensers equipped with level sensing.
Dispensing with precision syringes driven by stepping motors. REACTION END VOLUME: 100-250 µl.
SAMPLE CARRY OVER: <1%. REPRODUCIBILITY:
CV less than 2% for sample volumes ≥2 µl and for reagent volumes >5 µl
Dilutions
Automatic sample pre-dilution. Automatic post-dilution with both high and low secondary dilution ratios. Ability to add the value of manual pre-dilution for the result calculation.
DILUTION RATIOS: up to 1+120
Photometric Measurement
Single channel interference filter photometer with beam splitting reference- 11 fixed filters, others available upon request. SPECTRAL RANGE: 340-800 nm. MEASUREMENT TEMPERATURE: 37°C
MEASUREMENT PRINCIPLES: Colorimetric, turbidimetric . MEASUREMENT MODES:
Kinetic, end-point.
KINETIC MEASUREMENT:
30 sec to 60 min, max 12 points LIGHT SOURCE: Halogen lamp. with linear absorbance range of 0-2.5 A, resolution of 0.001 A and reproducibility of SD≤0.005 A at 2 A.
ISE Measurement in the model Konelab 20i
Direct potentiometry . Electrodes for Na+, K+ and Cl -; upon request Li+.
SAMPLES: Serum, plasma and urine.
USABLE RANGE: ( mmol /l)
serum , plasma:
K+ 2.0 - 10
Na+ 100 - 200
Cl- 55 - 150
serum :
Li+ 0.2 - 4.0
urine :
K+ 20 - 200 Na+ 20 200
Dimensions and Weight Width 80 cm, depth 79 cm, height 115 cm, weight 130 kg. Separate workstation table.
Power Requirements
100-240 V ±10%, 50-60 Hz ±5%, 300 W Konelab 20, 350 W Konelab 20i.
Distilled Water Consumption Typically <0.5 l/h
On-board storage with no external connections required.