Photometers / Spectrophotometers

Thermo Antaris II FT-NIR Spectrometer

Preis auf Anfrage
ID-number: 14435
Status: LabprocureLabprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.?
Shipping: 4-6 weeks
Description:
Easily implement the power of lab-based FT-NIR in a plant-ready package with the Thermo Scientific Antaris II FT-NIR Analyzer. With industry-leading method transfer performance, the Antaris II FT-NIR Analyzer delivers robust and reliable data acquisition for analysis: at-line, online and in-line. You can customize an Antaris II FT-NIR Analyzer for specific applications or choose the Antaris II MDS Method Development Sampling System, which includes transmission, fiber optic and integrating sphere diffuse reflectance analyzes in a turnkey system. Specifications:. Analyzer Type: Fourier Transform Near Infrared. Detection: Highly sensitive, highly stable tuned InGaAs. Height (Metric): 33 cm. Interface: Direct PC to Ethernet connection enables file system and OPC communication. Interferometer: Proven, smooth, stable, long-lasting Michelson. Length (Metric): 68.5 cm. Operating temperature range: 15°C to 35°C (59°F to 95°F). Photometric linearity: slope 1.0 ±0.05 and an intercept of 0.0 ±0.05. Resolution: 4 cm-1 over the entire spectral range (0.6 nm at 1250 nm), 2 cm-1 over the entire spectral range (0.3 nm at 1250 nm). Sampling mode: Configurable with reflection, transmission, fiber optic or tablet transmission. Sealed and dried: Yes. Source Type: Long-life, high-intensity halogen NIR source; Replacement source supplied with the system, guaranteed filament imaging alignment. Spectral range: 12,000 to 3,800 cmto1 (833 to 2,630 nm). System status indicators: Yes. Voltage: 90/264 V. Wavenumber accuracy: ±0.03 cm-1 (0.005 nm at 1250 nm). Wavenumber repeatability: Single system: 10 measurement standard deviation <0.006 cm-1. Wavenumber reproducibility: System to system: Better than 0.05 cm-1 (0.008 nm at 1250 nm). Weight (Metric): 47.7 kg. Width (Metric): 40.6 cm Labprocure is responsible for this device.
Quotation
More Information
Objektnummer C00014435
ID-number 14435
Object name Thermo Antaris II FT-NIR Spectrometer
Status Labprocure Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.
Manufacture Thermo
Shipping 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Product group: UV

Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
lazyOwllazyOwl
Labprocure