Tecan Sunrise RC
Objektnummer | B00013183 |
---|---|
ID-number | 013183 |
Object name | Tecan Sunrise RC |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
SUNRISE general speciticatioins
Optical system 12 measurement channnels
1 reference channel
Wavelength range 340 to 750 nm
Wavelength selection Interference filters (slide of 4 to 6 filters)
Bandwidth: 10nm
Measurement range 340 to 399 nm: 0 to 3.0 OD
400 to 750 nm: 0 to 4.0 OD
Measurement time - Single wavelength: 6 seconds
- Dual wavelength: 8 seconds
- Kinetic repeat time: 5 seconds
Accuracy 0.0 to 2.0 OD/492 nm: better than +/- 1% +/-0.010 OD
2.0 to 3.0 OD/492 nm: better than +/- 1.5% +/-0.010 OD
Linearity 340 to 399 nm: 0.0 to 2.0 OD better- than +/- 2%
400 to 750 nm: 0.0 to 2.0 OD better than +/- 1%
2.0 to 3.0 OD bettcr than +/- 1.5%
Precision 0.0 to 2.0 OD/492 nm: better than +/- 0.5% +/-0,005 OD
2.0 to 3.0 OD/492 nm: better than +/- 1.0% +/-0.005 OD
Resolution 0.001 OD
Interface RS 232 C (remote control)
Parallel Centronics (printer interface only wlth Option touchscreen)
Shaking Linear shaking in 4 different modes
Physical data Width 28.5 cm
Depth 34.0 cm
Height 14,5 cm / 21.0 cm with TS C
Weight min 6.2 kg Sunrise RC; max. 8,6 kg incl. all options
Sunrise absorbance reader: the tailor-made microplate reader suitable for diagnostic, pharmaceutical as well as research laboratories
Sunrise is a versatile microplate absorbance reader providing all the features needed for the numerous applications required in clinical diagnostics, biotechnology and the pharmaceutical industry. The sophisticated design with a 12-channel optical module guarantees high quality and excellent optical performance with fast, reproducible and accurate measurements. Options such as temperature control, different filter slides and a barcode scanner can be added to create a fully customized instrument configuration. Through a new touchscreen option, Sunrise can operate without a PC, saving space and adding a new dimension to ease-of-use and computer-independent data processing. The preferred language can be selected easily.
§ Absorbance measurement of 96-well microplates
§ Most comfortable onboard operation with TouchScreen Color
§ Measurement with high precision and high resolution
§ 4 filter, 6 filter or free wavelength selection filter slide
§ Fast measurement time: 6 seconds per microplate
§ Precise temperature control up to 42°C
§ 12 measurement channels and 1 reference channel
§ Compact and space-saving design
§ Easy integration in robotic systems
§ Designed to meet the Directive 98/79/EC for in vitro diagnostics
§ Magellan software for comprehensive data reduction
§ QC Pac tools for absorbance reader qualification guidances and checklists for instrument qualification (IQOQ package)