Archive

Tecan Genios FL

ID-number: 013587
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Tecan Microtitrationsplate Reader Genios FL. Wavelength 230-700nm.TWT Software Xfluor. YoC: 2005. Unused.
siehe Storeview
More Information
Objektnummer B00013587
ID-number 013587
Object name Tecan Genios FL
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Tecan

Modell:            Genios FL

Kommentar:   Dokumente deut.

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

GENios FL

1 = power LED

2 = emission filter

3 = excitation filter

4 = plate carrier

The GENios instruments are fully automatic, computer controlled microplate readers for measuring samples in a microplate. The instruments fulfill the requirements for numerous fluorescence, absorbance and glow type luminescence applications in research and routine investigations.

Note:   The GENios FL instrument does not have absorbance or glow type
luminescence measurement capabilities.

The GENios Reader offers fluorescence, absorbance, and glow type luminescence and can be used with 384, 96, 24, 12 or 6 well microplates.

The GENios FL Reader offers fluorescence top measurement with 384, 96, 24, 12 or 6 wells.

The GENios Plus Reader offers glow type luminescence, absorbance and fluorescence with high sensitivity especially in the UV range and the capability of measuring fluorescence in 1536 well plates.

The filters are arranged in filter slides; four excitation filters and four emission filters respectively. The instrument has no on-board software and is exclusively controlled via an external computer using Windows TM format.

Specifications (GENios FL)

The following types of measurement are provided with the GENios FL microplate reader.

Measurement Type

Read Mode

Microplates to be Used

Fluorescence

Standard and time-resolved,

top measurement

6 - 384 wells

The instrument allows for kinetic measurements. Reading may be restricted to one part of the microplate.

Up to four-measurement parameter sets can be queued using XFLUOR.

Parameters                            Characteristics

Measurement                          Software controlled

Interface                                  Serial interface: RS 232

Filter handling                          External filter exchange

            Up to 4 excitation filters and 4 emission filters in separate filter slides.

            Up to 8 excitation and emission filter slides can be defined when using software.

Plate definition                         Via scanning software

Plate shaking                           Orbital or linear shaking - both oller 3 speeds

Light source                            High energy Xenon flash lamp

Optics                                      PMMA fibers and lenses

Detector                                  Side window, Iow dark current photomultiplier tube

Power supply                          Auto-sensing:100-120V / 220-240V
50/60 Hz

Power consumption                200 VA

Main fuse                                 T 2A / 250 (slow blow)

Physical

Outer dimensions                   Width: 380 mm

                                               Depth: 415 mm

                                               Height: 170 mm

Weight                                     18.8 kg

Environmental

Ambient temperature

Operation                                15°C - 30°C                59°F - 86°F

Non-operation                          -20°C - +60°C                         -4°F - +140°F

Relative humidity

Operation                                90% non-condensing

Overvoltage category              II

Pollution degree                      2

Usage                                      Commercial

Noise level                               < 70 dBA

Method of disposal                  Electronic waste (infectious waste)

Fluorescence

Parameters                            Characteristics

Sensitivity                                ≤ 3 pg fluorescein / well (200 µI / well) or
≤ 8 fmol / well

                                               in a Greiner 96 well black plate using 100 flashes / well

Wavelength Range                 340 - 700 nm

Standard Filters                    Wavelength   Band Width 1 )

Excitation                                 1. 360nm         35nm

                                               2. 485nm         20nm

Emission                                 1. 465nm         35nm

                                               2. 535nm         25nm

Read Mode                              Top

Integration Time 2 )                   20 - 2000 µs

Lag Time 4 2 )                          0 - 2000 µs

Gain setting                           Values                        Measurement range

Manual                                     1 – 255                        0 - 60,000 RFU

Optimal                                    Automatic                    0 - 60,000 RFU

Extended Dynamic                  Automatic                    0 - 6,000,000 RFU

Range                                                                         (using XFLUOR)

1 ) Band width for standard filters may have some tolerance ± 10%

2 ) Needs to be adjusted for Time Resolved Measurements. Lag Time is typically 40 ps.

No. of Flashes /                    Definition                   Characteristic            Meas. Time for

Well                                                                                                               96 Wells

1 - 3                                         Plate carrier does      max. speed                 < 30 sec

                                               not stop at the

                                               measurement

                                               point (on the fly)

4 - 255                                     Plate carrier stops     max. precision             Dependent on the

                                               at the meas. point                                          flash parameter

                                                                                                                        setting

Product group: Microplate-Devices