Tecan Genesis WS150/4
| Objektnummer | B00010280 |
|---|---|
| ID-number | 010280 |
| Object name | Tecan Genesis WS150/4 |
| Status | Stock unit |
Product group: DNA-Sequencer
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Overview
The Assay Workstation consists of:
Assay Workstation Base Unit with cutout Worktable
Extension Kit (Worktable Extension)
Customer's choice of options and accessories.

Figure 1 - 1 GENESIS Assay Workstation 150/8 equipped

Figure 1 - 2 GENESIS Assay Workstation, Worktable equipped
Intended Use
The GENESIS Assay Workstation is intended for processing of microplate based tests, including liquid handling, incubation, wash, read and data acquisition. lt is to be applied exclusively in the research field.
The GENESIS Assay Workstation is intended to be part of a liquid handling system and as such installed and put into Operation by a trained System Integrator.
Unintended Use
Due to its open architecture, the GENESIS Assay Workstation is NOT intended for clinical and diagnostic applications. These applications would be carried out by less qualified people, exposing them to dangerous liquids in case of Instrument malfunction.
Do not attempt to use liquids with undissolved particles as this could result in liquid not being dispensed due to clogged tips.
Carefully observe the Safety Instructions in Chapter 2.
Assay Workstation, Basic Instrument
The Assay Workstation is produced in two different sizes, the arm is available with four or eight tips. 150 or 200 stands for the approx. instrument width in cm (without the worktable extension), the extension /4 means it is a 4-tip arm, /8 an 8-tip arm.

Figure 1 - 5 GENESIS Assay Workstation 150/8
Overview
The Logistics Workstation consists of:
Logistics Workstation Base Unit with RoMa
TECAN Carousel
Customer's choice of options and accessories.

Figure 1 - 6 GENESIS Logistics Workstation 150/8
Intended Use
The GENESIS Logistics Workstation is intended for pipetting tasks as well as storage, identification and transfer of microplates. lt is to be applied exclusively in the research field.
The GENESIS Logistics Workstation is intended to be part of a liquid handling system and as such installed and put into Operation by a trained System Integrator.
Unintended Use
Due to its open architecture, the GENESIS Logistics Workstation is NOT intended for clinical and diagnostic applications. These applications would be carried out by less qualified people, exposing them to dangerous liquids in case of instrument malfunction.
Do not attempt to use liquids with undissolved particles as this could result in liquid not being dispensed due to clogged tips.
Logistics Workstation, Basic Instrument
The Logistics Workstation is produced in three different sizes, the arm is available with four or eight tips. 100, 150 or 200 stands for the approx. instrument width in cm (without the worktable extension), the extension /4 means it is a 4-tip arm, /8 an 8-tip arm.

Figure 1 - 9 GENESIS Logistics Workstation 150/8
Specifications
Assay Workstation
Overall Dimensions

Figure 1 - 10 Overall Dimensions GENESIS Assay Workstation
Weights
|
|
150 |
200 |
|
Assay Workstation with 4-tip arm |
131 kg / 288 Ibs |
181 kg / 400 Ibs |
|
Assay Workstation with 8-tip arm |
138 kg / 295 Ibs |
188 kg / 414 Ibs |
|
Packing |
50 kg / 111 Ibs |
74 kg / 163 Ibs |
Worktable Dimensions
|
X-Range: |
WorKstation 150 925 mm Workstation 200 1525 mm |
|
|
Y-Range: |
418 mm |
total range from first to last Tip |
|
|
364 mm |
common range for all tips on 4-Tip Arm |
|
|
292 mm |
common range for all tips on 8-Tip Arm |
|
Z-Range: |
165 mm |
with Standard Tip |
|
|
185 mm |
with DiTi 200µl |
|
|
150 mm |
with DiTi 1000µl |
|
|
195 mm |
with LV DiTi 10µl |
Logistics Workstation
Overall Dimensions

Figure 1 - 11 Overall Dimensions GENESIS Logistics Workstation
Weights
|
|
100 |
150 |
200 |
|
Logistics WS with 4-tip arm |
104 kg / 230 Ibs |
123 kg / 271 Ibs |
173 kg / 381 Ibs |
|
Logistics WS with 8-tip arm |
111 kg / 245 Ibs |
130 kg / 286 Ibs |
180 kg / 397 Ibs |
|
MPO or FWO |
2 kg / 4.4 Ibs |
2 kg / 4.4 Ibs |
2 kg / 4.4 Ibs |
|
Packing |
35 kg / 77 Ibs |
47 kg / 104 Ibs |
71 kg / 156 Ibs |
Worktable Dimensions
|
|
100 |
150 |
200 |
|
Accessible X-range |
745 mm |
1120 mm |
1720 mm |
|
(X-travel) |
(29.3") |
(44.1") |
(67.7") |
|
Accessible Y-range |
418 mm |
418 mm |
418 mm |
|
(Y-travel) |
(16.5") |
(16.5") |
(16.5") |
|
Pin Columns |
30 |
45 |
69 |
Specifications applying to both Assay and Logistics WS
Supply Ratings
Primary Voltage: 100 - 240 VAC
Line Frequency 50 - 60 Hz
Secondary Voltage: 24 VDC
Power: 800 VA peak power RWS 100
1200 VA peak power RWS 150 and 200
Ground Line: Must be connected
Circuit breaker: 10 A RWS 100 / 15 A RWS 150 and 200
Environmental Conditions
Operating: Temperature 18 - 30°C / 64 - 86°F
Relative Humidity 30 - 80% at 30°C / 86°F or below (non condensing)
Storage: Temperature 1 - 60°C / 34 - 140°F
Relative Humidity 5 - 80% at 30°C / 86°F or below (non condensing)
Liquid System
System Liquid
Standard De-ionized water or aqueous buffer solution.
Optional Organic solvents, only with DMSO-resistant Tubing Set 619 417.
Tip Configuration
4 or 8 sampling tips arranged on one arm. Independent movement in Z-direction. In Y equidistant tip spreading of 9 - 38 mm / 0.31 - 1.5 inches. Any combination of Standard Tips and Disposable Tips (DiTis) possible.
Syringes, Tips
Syringe Volumes 250µl to 5 ml; with Low Volume Option 250µl and 500µl.
Free Dispense Volumes of 3 µl to max. syringe volume or max. DiTi volume.
With Low Volume Option 0.5µl to max. syringe volume or max. LV DiTi volume.
Precision* (TECAN Quality Control requirements)
TECAN guarantees the following values for free dispensing (single pipetting mode, with water). Tip Touch significantly improves these values.
Volume Fixed Tip DiTi 200 LV Fixed Tip LV DiTi 10
100µl CV ≤ 0.5% CV ≤ 0.5% - -
10µl CV ≤ 3% CV ≤_3% CV ≤ 3% CV ≤ 3%
1µl - - CV ≤ 10% CV ≤ 10%
* Values are valid only if maintenance instructions and schedule have strictly been followed.
Carryover
< 10 -6 with Standard Tips and Monitored Pump Option.
Liquid Detection
Detection of conductive liquids of ≥ 50 µl (in microplates with round bottoms).
Robotic Manipulator Arm
Force in Z-direction 35 N
Transportable mass 0.4 kg
Gripper force 1...4 N
Gripper space range 55 to 140 mm
Rotation angle 280°
Minimum Computer Requirements
Hardware: min. PC Intel Pentium ® , clock rate ≥ 100 MHz
(recommended Pentium 200 MMX or Pentium II)
min. 64 Mbytes RAM (recommended 128 Mbytes RAM
Monitor VGA (1024 x 768)
Hard disk with 250 Mbytes free space
Floppy disk drive 3.5" 1.44 MB
CD - ROM
One free serial port RS-232 onboard and parallel interface (printer port)
Digi multiple serial port card (Digi AccelePort 8e-ISA DB25)
Operating System: Windows NT ® ≥ 4.0, Service Pack ≥ 3
Specifications
Barcode Reader
Laser Class: Class IIA
Power: 220 mA @ 5 VDC
Barcode Types
The optional Barcode Reader on top of the Hotel for Microplates recognizes the following Barcode Types:
Code 39 Code 128
Code 39 Full ASCII 2/5 Interleaved
Code 93 2/5 Discrete
Codabar UPC A and E (EAN 8 and 13)
The scanner autodiscriminates between these codes except for Code 39 and Code 39 Full ASCII.
Barcode Specifications
Barcodes to be in accordance with specifications ANSI X3.182 and DIN EN 1635.
Module width 7.5 - 15 mils (0.19 - 0.381 mm)
Quiet zone ≥5 mm
Print Contrast Ratio PCS >70%
Barcode height ≥ 8 mm
Barcode length max. 64 mm (without quiet zone)
Number of characters: max. 32
Black code on white background
Recommendations in regard to Barcode Quality
Use barcode testing device to verify barcode quality.
Quality Class A, B or C required. Identification of Class D is not guaranteed.
Print Quality: Use barcodes printed by thermal-transfer or photographic methods
Code label surface to be mat and clean
Do not use yellowed, dirty or damaged barcodes
Barcode positioning

Figure 1 - 12 Barcode Label Position on Microplates