Description:
Tecan Workstation Genesis WS 150/4. Gemini Software. RoMa and Barcode Reader. Sunrise Reader with Magellan Software. Incubator for 6 plates. YoC: 2001.
Quotation
siehe Storeview
More Information
Objektnummer B00010280
ID-number 010280
Object name Tecan Genesis WS150/4
Status Stock unit

Product group: DNA-Sequencer

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Tecan

Modell:            Genesis WS150/4

Kommentar:   Dokumente engl.

Overview

The Assay Workstation consists of:

•     Assay Workstation Base Unit with cutout Worktable

•     Extension Kit (Worktable Extension)

•     Customer's choice of options and accessories.

Figure 1 - 1 GENESIS Assay Workstation 150/8 equipped

Figure 1 - 2 GENESIS Assay Workstation, Worktable equipped

Intended Use

The GENESIS Assay Workstation is intended for processing of microplate based tests, including liquid handling, incubation, wash, read and data acquisition. lt is to be applied exclusively in the research field.

The GENESIS Assay Workstation is intended to be part of a liquid handling system and as such installed and put into Operation by a trained System Integrator.

Unintended Use

Due to its open architecture, the GENESIS Assay Workstation is NOT intended for clinical and diagnostic applications. These applications would be carried out by less qualified people, exposing them to dangerous liquids in case of Instrument malfunction.

Do not attempt to use liquids with undissolved particles as this could result in liquid not being dispensed due to clogged tips.

Carefully observe the Safety Instructions in Chapter 2.

Assay Workstation, Basic Instrument

The Assay Workstation is produced in two different sizes, the arm is available with four or eight tips. 150 or 200 stands for the approx. instrument width in cm (without the work­table extension), the extension /4 means it is a 4-tip arm, /8 an 8-tip arm.

Figure 1 - 5 GENESIS Assay Workstation 150/8

Overview

The Logistics Workstation consists of:

•     Logistics Workstation Base Unit with RoMa

•     TECAN Carousel

•     Customer's choice of options and accessories.

Figure 1 - 6 GENESIS Logistics Workstation 150/8

Intended Use

The GENESIS Logistics Workstation is intended for pipetting tasks as well as storage, iden­tification and transfer of microplates. lt is to be applied exclusively in the research field.

The GENESIS Logistics Workstation is intended to be part of a liquid handling system and as such installed and put into Operation by a trained System Integrator.

Unintended Use

Due to its open architecture, the GENESIS Logistics Workstation is NOT intended for clini­cal and diagnostic applications. These applications would be carried out by less quali­fied people, exposing them to dangerous liquids in case of instrument malfunction.

Do not attempt to use liquids with undissolved particles as this could result in liquid not being dispensed due to clogged tips.

Logistics Workstation, Basic Instrument

The Logistics Workstation is produced in three different sizes, the arm is available with four or eight tips. 100, 150 or 200 stands for the approx. instrument width in cm (without the worktable extension), the extension /4 means it is a 4-tip arm, /8 an 8-tip arm.

Figure 1 - 9 GENESIS Logistics Workstation 150/8

Specifications

Assay Workstation

Overall Dimensions

Figure 1 - 10 Overall Dimensions GENESIS Assay Workstation

Weights

150

200

Assay Workstation with 4-tip arm

131 kg / 288 Ibs

181 kg / 400 Ibs

Assay Workstation with 8-tip arm

138 kg / 295 Ibs

188 kg / 414 Ibs

Packing

50 kg / 111 Ibs

74 kg / 163 Ibs

Worktable Dimensions

X-Range:

WorKstation 150       925 mm

Workstation 200        1525 mm

Y-Range:

418 mm

total range from first to last Tip

364 mm

common range for all tips on 4-Tip Arm

292 mm

common range for all tips on 8-Tip Arm

Z-Range:

165 mm

with Standard Tip

185 mm

with DiTi 200µl

150 mm

with DiTi 1000µl

195 mm

with LV DiTi 10µl

Logistics Workstation

Overall Dimensions

Figure 1 - 11 Overall Dimensions GENESIS Logistics Workstation

Weights

100

150

200

Logistics WS with 4-tip arm

104 kg / 230 Ibs

123 kg / 271 Ibs

173 kg / 381 Ibs

Logistics WS with 8-tip arm

111 kg / 245 Ibs

130 kg / 286 Ibs

180 kg / 397 Ibs

MPO or FWO

2 kg / 4.4 Ibs

2 kg / 4.4 Ibs

2 kg / 4.4 Ibs

Packing

35 kg / 77 Ibs

47 kg / 104 Ibs

71 kg / 156 Ibs

Worktable Dimensions

100

150

200

Accessible X-range

745 mm

1120 mm

1720 mm

(X-travel)

(29.3")

(44.1")

(67.7")

Accessible Y-range

418 mm

418 mm

418 mm

(Y-travel)

(16.5")

(16.5")

(16.5")

Pin Columns

30

45

69

Specifications applying to both Assay and Logistics WS

Supply Ratings

Primary Voltage:                 100 - 240 VAC

Line Frequency                   50 - 60 Hz

Secondary Voltage:            24 VDC

Power:                                800 VA peak power RWS 100

                                           1200 VA peak power RWS 150 and 200

Ground Line:                       Must be connected

Circuit breaker:                   10 A RWS 100 / 15 A RWS 150 and 200

Environmental Conditions

Operating:        Temperature 18 - 30°C / 64 - 86°F

Relative Humidity 30 - 80% at 30°C / 86°F or below (non condensing)

Storage:           Temperature 1 - 60°C / 34 - 140°F

Relative Humidity 5 - 80% at 30°C / 86°F or below (non condensing)

Liquid System

System Liquid

Standard          De-ionized water or aqueous buffer solution.

Optional           Organic solvents, only with DMSO-resistant Tubing Set 619 417.

Tip Configuration

4 or 8 sampling tips arranged on one arm. Independent movement in Z-direction. In Y equidistant tip spreading of 9 - 38 mm / 0.31 - 1.5 inches. Any combination of Standard Tips and Disposable Tips (DiTis) possible.

Syringes, Tips

Syringe Volumes 250µl to 5 ml; with Low Volume Option 250µl and 500µl.

Free Dispense Volumes of 3 µl to max. syringe volume or max. DiTi volume.

With Low Volume Option 0.5µl to max. syringe volume or max. LV DiTi volume.

Precision* (TECAN Quality Control requirements)

TECAN guarantees the following values for free dispensing (single pipetting mode, with water). Tip Touch significantly improves these values.

Volume                 Fixed Tip               DiTi 200                LV Fixed Tip          LV DiTi 10

100µl                     CV ≤ 0.5%            CV ≤ 0.5%            -                            -

10µl                       CV ≤ 3%               CV ≤_3%              CV ≤ 3%               CV ≤ 3%

1µl                         -                            -                            CV ≤ 10%             CV ≤ 10%

* Values are valid only if maintenance instructions and schedule have strictly been followed.

Carryover

< 10 -6 with Standard Tips and Monitored Pump Option.

Liquid Detection

Detection of conductive liquids of ≥ 50 µl (in microplates with round bottoms).

Robotic Manipulator Arm

Force in Z-direction 35 N

Transportable mass 0.4 kg

Gripper force 1...4 N

Gripper space range 55 to 140 mm

Rotation angle 280°

Minimum Computer Requirements

Hardware:   min. PC Intel Pentium ® , clock rate ≥ 100 MHz

                   (recommended Pentium 200 MMX or Pentium II)

                   min. 64 Mbytes RAM (recommended 128 Mbytes RAM

                   Monitor VGA (1024 x 768)

                   Hard disk with 250 Mbytes free space

                   Floppy disk drive 3.5" 1.44 MB

                   CD - ROM

                   One free serial port RS-232 onboard and parallel interface (printer port)

                   Digi multiple serial port card (Digi AccelePort 8e-ISA DB25)

Operating System: Windows NT ® ≥ 4.0, Service Pack ≥ 3

Specifications

Barcode Reader

Laser Class:                       Class IIA

Power:                                220 mA @ 5 VDC

Barcode Types

The optional Barcode Reader on top of the Hotel for Microplates recognizes the following Barcode Types:

•     Code 39                         • Code 128

•     Code 39 Full ASCII        • 2/5 Interleaved

•     Code 93                         • 2/5 Discrete

•     Codabar                         • UPC A and E (EAN 8 and 13)

The scanner autodiscriminates between these codes except for Code 39 and Code 39 Full ASCII.

Barcode Specifications

Barcodes to be in accordance with specifications ANSI X3.182 and DIN EN 1635.

•     Module width 7.5 - 15 mils (0.19 - 0.381 mm)

•     Quiet zone ≥5 mm

•     Print Contrast Ratio PCS >70%

•     Barcode height ≥ 8 mm

•     Barcode length max. 64 mm (without quiet zone)

•     Number of characters: max. 32

•     Black code on white background

Recommendations in regard to Barcode Quality

Use barcode testing device to verify barcode quality.

Quality Class A, B or C required. Identification of Class D is not guaranteed.

• Print Quality: Use barcodes printed by thermal-transfer or photographic methods

• Code label surface to be mat and clean

• Do not use yellowed, dirty or damaged barcodes

Barcode positioning

Figure 1 - 12 Barcode Label Position on Microplates