Systec 3870 ELV

ID-number: 020335
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Systec Autoclave 3870 ELV. Automatic VE water supply. Thermal barrier 80°C. With sieve basket. Unused
siehe Storeview
More Information
Objektnummer B00020335
ID-number 020335
Object name Systec 3870 ELV
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

manufacturer:       Systec

model:                   3870 ELV

annotation:           Dokumente engl.

 

 

 

 

 

 

 

Systec laboratory autoclaves series ELV are used wherever reproducible and safe sterilization processes and successful results are required – in research institutes, microbiological and quality control laboratories and in the food and pharmaceutical industries.

 

 

Sterilization applications

  • Liquids such as nutrient media and buffer solutions
  • Solid items such as pipettes, tubes, filters, glassware and plastic articles
  • Waste sterilization

 

 

The right system for every type of sterilization

Fully automatic, microprocessor-controlled.

The various applications can be carried out using the autoclave’s standard programmes. Additional options ensure even more efficient work, with control of results and optimal, safe and reproducible sterilization processes.

 

 

Built-in technical progress

  • Controlled steam release after sterilization to avoid overboiling of the liquid products
  • Programmable start time
  • Warming function to a presetable temperature of 25 – 80°C after sterilization
  • Autofill for demineralised water
  • Special cleaning programme
  • Waste program with pulsed heat up for waste sterilization in waste bags to optimize air removal out of waste bags

 

 

Process control

Via state-of-the-art microprocessor technology

 

 

Programmes

6 individual programmes standard

 

 

LCT display

For pressure, temperature, time and errors

 

 

Sterilization parameters

Temperature and time are freely selectable; temperature can be set between 60 and 138°C. Sterilizing time can be set from 1 – 99 minutes. Preselected parameters remain programmed until altered.

 

 

Sterilization initiation

A PT 100 temperature sensor in a reference vessel guarantees that the set sterilization temperature is actually attained before sterilization starts.

 

 

RS 232 Interface

 

 

Demineralised water level regulation

Feed water for steam generation is automatically regulated.

 

 

Exhaust steam condensation

Exhaust steam is cooled down before leaving the autoclave. No unnecessary steam is exhausted. Drainage equipment protected from contact with steam.

 

 

Heat-resistant plastic covering on lid

Prevents contact with hot parts and protects from burning.

 

 

Pressure-dependent door lock

Prevents the door from being opened whilst under pressure.

 

 

Temperature-dependent door lock

In conjunction with temperature measurement in a reference vessel, the system prevents the door from being opened until the temperature is below a specified level. Hence preventing delayed boiling (as specified by technical regulations for pressure vessels, complies with British-and German Standards)

 

 

Door lock safety switch

Prevents the sterilization programme from being started if the door is not properly closed.

 

 

Water level safety device

Prevents the autoclave from being heated up if insufficient water is available for steam generation.

 

 

Excess temperature safety device

Switches off the heating elements if too high a temperature is attained.

 

 

Overpressure valve

Release of too high pressure.

 

 

 

 

Short batch times with intelligent technology

 

The actual sterilization time of e.g. 15 to 20 minutes at 121°C is only a fraction of the total time involved in the sterilization process.

 

Especially when sterilizing liquids, the heating and cooling phases are much longer.

 

State-of-the-art technology makes it possible to reduce the entire batch time considerably – several hours can be saved. In addition, this also means that media need not be exposed unduly long to high temperatures.

 

In conventional autoclaves, the prescribed temperature may well be reached in the vessel, but the liquids to be sterilized may only be at e.g. 100°C; the overall time required to attain equilibrium between vessel and liquid is hence much longer.

 

 

 

 

Up to 50 % less heating time – in all autoclaves!

 

This system is different! Due to the dual temperature and pressure control, the chamber pressure and hence temperature is increased in the heating phase. Temperature equilibrium is thus attained much more quickly and the overall sterilization time is shorter.

 

Up to 90 % less cooling time – optional!

 

The specially developed rapid cooling system – with or without support pressure – enables cooling time to be reduced by up to 90 %. This system can also be fitted retrospectively.

 

 

 

 

Technical data serie ELV

 

Type

3870 ELV

 

Chamber dimensions Ø x depth in mm

380 x 690

 

Chamber volume in litres

85

 

External dimensions (W x H x D)

650 x 955 x 500

 

Heating performance in KW

6.0

 

Voltage in Volts 50/60 Hz

380 – 400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product group: Autoclaves