Archive

Siemens ADVIA 120

ID-number: 020250
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Siemens Hematology System ADVIA 120. With OKI-printer. New computer unit with monitor. Sample racks. 230 V. 50/60 Hz. Software ADVIA 2.4 for control and evaluation on CD-ROM. Is currently running under LIS Cobas IT-5000. Maintenance contract currently still active. Device is currently still in a district hospital in routine analytical applications. Available from March 2012. Similar to the ADVIA 2120i. Acrylate block (Block UFC) in February 2012 replaced by manufacturer service. As new.
siehe Storeview
More Information
Objektnummer B00020250
ID-number 020250
Object name Siemens ADVIA 120
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Firma:              Bayer Diagnostic

Modell:            Advia 120

Kommentar:   Dokumente engl.

The ADVIA 120 Hematology System - Gets The Job Done

The ADVIA 120 Hematology System from Bayer Diagnostics gets the job done and gets it right the first time, with a review rate far lower than competing systems. Results are more accurate, physicians are more confident and treatment is more effective.

The ADVIA 120 Hematology System, for great performance, the one and only.

Advancing world standards in hematology

Improve your service to clinicians and patients with the ADVIA 120 Hematology System.

A system that is designed to streamline laboratory workflow and achieve long-term economic benefits...a system you can always rely on to get the right results the first time. This simple benchtop analyzer offers a unique portfolio of diagnostic assays, meeting the needs of clinicians, enhancing patient management and adding value to your laboratory.

Elevates your standards

The ADVIA 120 system features patented, proprietary clinical parameters - raising the level of care your physicians can provide.

• Benefit from technology which utilizes Peroxidase staining-the gold standard for differential testing.

• Detect abnormalities early and differentiate leukemias with cytochemical staining and nuclear complexity.

• Maximize the effectiveness of costly platelet transfusions with accurate results the first time, every time - even at very low platelet levels.

• Achieve sensitive detection of red cell abnormalities without recourse to expensive and time-consuming manual tests.

• Differentiate microcytic anemias (thalassemia, iron deficiency) and macrocytic anemias (hereditary spherocytosis, sickle cell) with RBC and reticulocyte technology.

• Detect and treat iron deficiency anemia using CHr TM . %Hypo assay* maybe a useful tool in the investigation of iron deficiency.

*%Hypo assay is for research use only, not for use in diagnostic procedures in the US. The CHr assay has been cleared by the FDA. Both tests are available only on the Bayer Hematology systems.

Really means business

• Use of the ADVIA 120 Hematology System enables you to achieve immediate workflow efficiencies. This enhances patient care by facilitating the path to diagnosis, while freeing skilled laboratory staff for other tasks.

• Rack-based capacity for 150 samples delivers all the benefits of "walkaway" convenience .

• Fixed throughput of CBC/Diff at 120 samples per hour, even on leukopenic samples, provides fast results reporting to enhance the service to clinicians.

• Accurate results on all samples whether immediately post-collection or up to 54 hours old reduce the need for retesting.

• Increased linearities minimize costly, timeconsuming dilutions and repeats.

• Proven technology, reference methods and onboard delta checks reduce manual slide reviews.

• Internal QC checks on every sample allow results to be reported with confidence, as anomalous results are highlighted automatically.

Saves for the future.

• Supplies, equipment, staffing: On every front, the ADVIA 120 Hematology System helps you reallocate resources, reduce costs – and deliver better results.

• Cross-train operators easily on intuitive software, minimizing the need for dedicated staff.

• Select only the tests the physician orders.

• Eliminate separate reticulocyte analyzer – workstation has fully automated random-access reticulocytes; no batching is required.

• Right results the first time saves unnecessary reagent usage, reduces film review rates and minimizes the need for time-consuming repeats.

Product specifications

Performance Specifications

WBC

0.02 to 400 x 10 3 /µL

RBC

0.0 to 7.0 x 10 6 /µL

PLT

5.0 to 3500 x 10 3 /µL

Hgb

0.0 to 22.5 g/dL

Retic

0.2 to 24.5%

Precision

Parameter

Mean

SD

CV

WBC

7.5

0.20

2.7

RBC

5.0

0.06

1.2

Hgb

15.0

0.14

0.93

MCV

90.0

0.7

0.78

Plt

300.0

8.8

2.93

Retic%

2.0

0.25

12.5

Parameters

CBC Results:

WBC, RBC, HGB, HCT, MCV, MCH, MCHC, CHCM, RDW, HDW, CH, CHDW, PLT.

Differential Results

(absolute and %):

NEUT, LYMPH, MONO, EOS, BASO, LUC (Large Unstained Cells).

Platelet Results:

PLT, MPV, PDW, PCT.

Reticulocyte Results:

% and # RETIC, MCVr, CHCMr, RDWr,** HDWr,** CHr, CHDWr**.

Morphology results (User definable)

WBC:

Left Shift, Atypical Lymph, Blasts, BL-ABN, Immature Granulocytes, Myeloperoxidase Deficiency.

RBC:

NRBC, ANISO, MICRO, MACRO, HC VAR, HYPO, HYPER, RBC Fragments, RBC Ghosts, Platelet Clumps, Large Platelets.

Test Selectivity / Throughput

CBC

120 Samples/hr.

CBC/DIFF

120 Samples/hr.

CBC/DIFF

74 Samples/hr.

CBC/Retic

74 Samples/hr.

Retic

74 Samples/hr.

Sample Modes/Volumes

Automatic Closed Tube 157 µL

Manual Closed Tube 157 µL.

Manual Open Tube 157 µL.

Weight and Dimensions

Analytical Module with Autosampler (including reagents):

Weight

193 kg / 425 Ibs

Height

86 cm / 33,8 in

Width

141 cm / 55.5 in

Depth

68 cm / 26,8 in

Analytical Module without Autosampler (including Reagents):

Weight

163 kg / 360 Ibs

Height

86 cm / 33.8 in

Width

81 cm / 31.9 in

Depth

68 cm / 26.8 in

Data Management

Data Base

10,000 Patient Storage Capacity

Including Graphics

Review and Edit Capability:

User Defined Windows

User Defined Reports

User Defined ranges based an Age and Sex for

Normal Range, Panic, Rerun and Delta Check Criteria

Bi-Directional and Host

Query Communication

Protocols.

Extensive Quality Control:

3D Bar Graph

Levy-Jennings Plot

SDI Graphs

Table Format

Remote QC.

ILQC Program.

Patient Moving

Average.

Extensive On Line Documentation:

Context Sensitive Field Help

Operations Manual

Procedure Wizards Assistance

Problem Solving Diagnostics

Remote Diagnostics

Workstation Specifications

Windows NT.

15 Gigabyte Hard Disk Drive.

128 MB Memory.

CD-RW.

17" Color Monitor.

Full size Keyboard (Major Languages).

Physical Specifications

Electrical Power

Dedicated Line

Requirements:

Voltage Selectable for Single-Phase:

100 VAC (6 AMPS) - 240 VAC (3 AMPS)

Frequency: 50/60 HZ

Temperature:

Operating: 18°C – 32°C

Requirements:

Storage: -40°C - +70°C

Relative Humidity:

Operating: 15% - 80% (noncondensing)

Heat Generation - less than 3000 BTU's.

Waste Disposal:

Azide-free reagents drain into a waste container with automatic level-sensor shutoff

Optional auto waste removal system

Auto Sampler Option

150 Sample Capacity:

15 Racks with 10 tube capacity

Compatible Tube Type:

Vacutainer, Hemogard, Monovette, (Sarstedt 2.6 ml tubes require rack modification)

Bar Code Reader:

Up to 14 digits

Automatic discrimination of label

Codabar

Interleave 2 of 5 with and without check digit

Codes:

Codabar

Interleave 2 of 5 with and without check digit Code 39

Code128 EAN and JAN (8 and 13)

Other Specifications

Windows NT

Onboard analytical and wash reagents (1850 CBC/Diff tests).

Automated Daily Maintenance – fully programmable.

Product group: Hematology