Shimadzu UV 240
Objektnummer | B00013017 |
---|---|
ID-number | 013017 |
Object name | Shimadzu UV 240 |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Specifications
Wavelength Range 190~900nm
Light Source 50W halogen lamp (2000 hrs" life) and deuterium lamp (alignment free socket type)
Light Source Changeover Automatic mirror changeover linked with the wavelength, and automatic turning-on of lamp according to the wave length range selected. The changeover wavelength can be selected in a range from 295nm to 364nm.
Monochromator Aberration-corrected Czerny-Turner mounting with a blazed holographic grating.
Spectral Bandwidth Variable from 0.008nm to 5nm in 0.001nm steps.
Resolution Better than 0.15nm
Stray Light Less than 0.05%T at 340nm (UV-39 filter)
Less than 0.05%T at 220nm (Nal, 10g/l)
Wavelength Readout 4-digit LED, readable to 0.1nm
Wavelength Accuracy ±0.3nm with automatic wavelength correction.
Wavelength Reproducibility ±0.1nm*
Detector Photomultiplier R-928-05
Photometric System Double-beam, direct ratio recording system by dynode feedback.
Recorder Computer-controlled digital recorder of thermal graphic printer type
Chart Paper Temperature-sensitive rolled chart paper, 170mm in effective width, A4 size, ruled in Abscissa and Ordinate scales. Non-ruled paper is optionally available.
Recording Mode 1. Recording of spectral curves and time-course change of photometric value, by solid line or three types of broken lines.
2. Printout of photometric values with sample numbers (2 figures).
3. Drawing of format, which includes printout of instrumental parameters and drawing of X and Y axes with main numerical values.
Repetitive Scanning Selectable between OVERLAY mode and SEQUENTIAL mode. Cycle time is selectable from 0 to 100 minutes. The number of repetition is selectable from 1 to 100 times.
Photometric Range l. Display: 4-digit LED and negative sign Transmittance: 0.00~160.0%T.
0.01% division (below 100%T)
Absorbance: -0.200~3.999 Abs. (0.001 Abs.division) Energy: Arbitrary unit
2. Recorder: Upper and lower limits of the full scale are digitally set in 0.1%T or 0.001 Abs.increments.
Effective full scale is:
1~160%T in %T Range
-0.200~4 Abs. in Abs. Range
Selectable range is:
-1000~+1000%T in 0.001%T steps
-9.999~+9.999Abs. in 0.001Abs. steps
Photometric Accuracy ±0.002 Abs. in 0~0.5 Abs. \ inspected with
±0.004 Abs. in 0.5~1.0 Abs.> NBS 930
±0.3%T in 0~100%T / standard filters.
Drift Less than 0.0004 Abs/h (after 2 hr. worm-up)
Wavelength Setting Starting and ending wavelengths are both set digitally.
The GO TO λ key is provided to move the wavelength to a desired position by one-touch operation. Wavelength can be set in 0.1nm steps.
Quantitative Calculation Mode l. Automatic concentration calculation by the least square calibration system and printout of the results.
2. Calculation of data obtained from two/three wavelengths, and printout of the results.
Scanning Speed 4-step selection, FAST, M (medium), SLOW, and ACC (accumulation). The built-in automatic scanning speed suppression system ensures distortion-free spectra irrespective of the scanning speed selected.
Wavelength Scale Expansion Five steps of 2.5, 5, 10, 20, 40nm/cm
Baseline Correction Automatically corrected by the built-in baseline memory at the initializing period. A correction
command key is incorporated for later correction.
Baseline Flatness ±0.001 Abs. for 195~860nm with 2nm slit width
(excluding noise) ±0.001 Abs. for 190~900nm with 5nm slit width.
In order to test baseline flatness both memorize and record at slow scan speed.
Response Automatically adjusted according to the slit width.
Auto-Zero Adjustment One-touch operation by the ABS 0 100%T key
Sample Compartment Maximum optical path length for cell: 100mm
Cartridge system for easy mounting and dismounting and washing.
A standard cell holder for a pair of l0mm square cells (for sample and reference beams) is attached.
Effective inner space: 110mm wide (in optical path direction), 230mm deep and 170mm high.
Power Requirements 100, 115, 220 and 240V, selectable by line voltage Selection switch: 50/60Hz, 300VA
External Dimensions Spectrophotometer main body: 480mm wide, 560mm deep and 190mm high
Graphic printer: 400mm wide, 520mm deep and 170mm high
Weight Spectrophotometer main body: 32kg
Graphic printer: 13kg
*Note: The wavelength reproducibility is inspected using GO TO λ key from longer wavelengths.