Sold

Shimadzu UV 160A

ID-number: 001712
Status: Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
Shimadzu recording UV/VIS- spectrophotometer UV-160A. YoC:1990. Newprice: 15.140,- DM.
Quotation
siehe Storeview
More Information
Objektnummer B00001712
ID-number 001712
Object name Shimadzu UV 160A
Status Stock unit

Product group: Photometers / Spectrophotometers

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Shimadzu

Modell:                         UV 160A

Kommentar:     Dokumente engl.

 

 

 

 

 

 

FEATURES

Excellent ease of operation

The UV-160A has only 24 single-function keys. High-level data processing is easily carried out through dialog with the video display software.

 

High-speed scanning-up to 3600nm/min.

lt takes only two seconds to scan a 100nm spectral range. The entire 1100 ~ 200nm range may be scanned in 25 sec. including the automatic lamp changeover. The monochromator will slew at 60nm/sec. for single wavelength selection.

 

Spectral bandwidth of 2nm

Shimadzu's renowned blazed holographic grating provides a sharp 2nm bandpass over the entire wavelength range.

 

Reliable measurement of micro samples

The optional super micro cell holder is convenient for measurement of precious samples such as isolated proteins or nucleic acids. Sample volumes as small as 50µl may be measured reliably.

 

A large variety of quantitative functions

The standard programs include: (1) quantitation by the least squares calibration method or multilinear method using a single wavelength, two or three additional background wavelengths, or derivative values, (2) multicomponent analysis, and (3) kinetic activity assay.

 

Highest spectral data processing capability in its class

Graphic expansion and compression, peak picking, differentiation, smoothing, memory storage, arithmetic calculation between files, and much more are available for spectral scan data.

 

Color X-Y plotter available

The addition of an optional plotter allows publishable-quality output of graphic and digital data.

 

Amber video display

The amber video display allows easy user interaction and feedback and minimizes eye fatigue.

 


Specifications

 

Wavelength Range

200 ~ 1100nm

Spectral Bandvvidth

2nm

Wavelength Display

Video display , readable to 0.1 nm

Wavelength Setting

0.1nm steps

Wavelength Accuracy

± 0.5nm, with automatic wavelength correction

Wavelength Repeatability

± 0.1nm

Wavelength Drive Speed

No data sampling About 3600nm/min.

FAST About 2400nm/min.

M About 1500nm/min.

SLOW About 480nm/min.

Data Sampling Interval

Automatically set according to the wavelength range to be scanned (λ-range)

900nm (λ-range) > 500nm 1nm

500nm (λ-range) > 200nm 0.5nm

200nm (λ-range) > 100nm 0.2nm

100nm (λ-range) 10nm 0.1 nm

Light Source Changeover

The wavelengths for lamp changeover can be selected in a range from 295nm to 364nm. The changeover is made automatically.

Stray Light

Less than 0.1%T at 220nm and 340nm

Photometric System

Double-beam optics

Photometric Range

Absorbance: -2.0 ~ 2.0 Abs.

Transmittance: 1 ~ 125%T

Recording Range

Absorbance: -2.5 ~ 2.5 Abs

Transmittance: -125 ~ 125%T

Photometric Value Presentation

CRT (amber), printer, and optional color X-Y plotter

Photometric Accuracy

± 0.005Abs. at 1.0 Abs. (Tested with NBS 930D filter)

Photometric Repeatability

± 0.002Abs. at 1.0 Abs.

Auto-Zero Adjustment:

One-touch key operation

Baseline Stability

Better than 0.001 Abs/hour after 2-hour warm-up

Baseline Correction

Baseline memory is incorporated, so baseline is automatically corrected at the start of a run. A baseline correction command is available for later correction.

Baseline Flatness

Better than ± 0.002Abs.

Recording Mode

Printout of photometric values and calculation results

Recording of spectral curve, various graphs, instrument parameters, and digital data. (Hard copy of CRT

image)

Repetitive Scanning

Selectable between OVER LAY mode and SEQUENTIAL mode. Cycle time is adjustable from 1 second to 9999 seconds and the number of repetitions from 1 to 99.

Data Processing Functions

Two/three wavelength operation (Absorbance ratio is also available)

4-data calculation

Wavelength program (for 5 wavelengths)

Data memory, 2 channels (2K bytes X 2)

Expansion or compression of absorption/time-course spectra

Peak picking in absorption/time-course spectra

1st ~ 4th derivative of absorption/time-course spectra

Smoothing of absorption/time-course spectra

Output of photometric value at a given wavelength/time interval

Readout of photometric value by cursor location

Calculation of enzyme activity by the method of least squares

Automatic concentration calculation by linear or multilinear calibration curve (Quantitation by two/three wavelength method or derivative method is also possible)

Quantitative calculation of up to 8 components

Arithmetic calculation between spectra

Connection to External PC

Via optional RS-232C interface and GPIB interface.

Backup Functions

Up to 20 sets of instrument parameters (including calibration curve and matrix for multicomponent analysis), and date

Date Display

Year, month, day, hour, and minute are presented on the CRT. (Can be turned off.)

Light Source

50W halogen lamp (2000 hour life) and deuterium lamp (alignment-free socket type), Automatic positioning system.

Monochromator

Aberration-corrected concave blazed holographic grating

Detector

Silicon photo diode

Recorder

Computer-controlled thermal graphic printer

Recorder Chart

Heat-sensitive rolled paper, 110mm in effective width (280 dots)

Sample Compartment

110 W X 230 D X 105 H mm in inner dimensions, 100mm in beam-to-beam distance. Cartridge design to permit rapid dismounting.

Power Requirements

100/115/220/240V switch selectable, 50/60Hz, 300VA

Dimensions and Weight

630 W X 500 D X 450 H mm, 42 kg

Ambient Requirements

Temperature: 15 ~ 35°C

Humidity: 45 ~ 80% (Below 70% when ambient temperature is above 30°C)

 

 

DIMENSIONS

 

Part of labexchange logo
Search engine powered by ElasticSuite