Shimadzu UV 120-02
| Objektnummer | B00007889 |
|---|---|
| ID-number | 007889 |
| Object name | Shimadzu UV 120-02 |
| Status | Stock unit |
Product group: Photometers / Spectrophotometers
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Features
Digital display
The 4-figure digital meter ensures rapid and accurate readout of photometric values.
Highly stable and low-noise silicon photocell of a wide wavelength range.
The silicon photocell covers a wide wavelength range from 200nm to 1000nm, and ensures far lower noise and drift, compared with conventional phototubes.
Blazed holographic grating of unique design*
The combined technique of laser holography and ion-beam etching has produced a grating with minimized stray light.
Easy operation
The filters are automatically changed over, so that any errors in manual operation are eliminated. The prealigned deuterium lamp and tungsten lamp require no re-alignment after replacement.
Spacious sample compartment
The sample compartment is a cartridge type so that it can be easily mounted or dismounted and that it can be easily washed. Made of stainless steel, it is corrosion free.
Various attachments can be easily mounted and dismounted; it is quite easy to position them in the sample compartment.
Compact and lightweight with a built-in power supply
UV-120 series weighs only 19 kg (42 lbs.) and measures only 505 mm (20") wide, 374 mm (14¾") deep, and 240 mm (9½ ") high.
Wide variety of attachments (option)
Attachments for rapid measurement of many samples, such as auto flow-thru cell, semi-auto flow-thru cell, and funnel-type flow-thru cell, are available.
*Based on a patent of Institute of Physical and Chemical Research, Japan.
SPECIFICATIONS
The UV-120 is available in two types of UV-120-01 (visible range only) and UV-120-02 (UV and visible ranges)
|
Model |
UV-120-02 |
|
Wavelength range |
200- 1000nm |
|
Wavelength indication |
3-figure digital counter (0.2nm divisions) |
|
Wavelength accuracy |
± 2nm |
|
Wavelength reproducibility |
± 0.3nm |
|
Monochromator |
Blazed holographic grating |
|
Spectral bandwidth |
7nm (constant) |
|
Stray light |
Less than 0.1% at 340nm and less than 0.15% at 220nm |
|
Light source |
Tungsten lamp and deuterium lamp. Socket type requiring no re-adjustment. |
|
Detector |
Wide-range silicon photocell |
|
Filter changeover |
Automatic |
|
Photometric range (4-figure digital display) |
Transmittance: 0~100%T (000.0~199.9) Absorbance: 0~2 Abs. (0.000~1.999) 0~3 Abs. (0.00~3.00) Concentration: CONC. (0000~1999) |
|
Photometric accuracy |
±0.5%T at 30%T, tested with the standard NBS-930 glass filter |
|
Photometric reproducibility |
± 0.1%T (0~100%T) ± 0.003 Abs at 1.0 Abs |
|
Noise level |
± 0.001 Abs at 0 Abs ± 0.003 Abs at 1.0 Abs ± 0.01%T at 0%T |
|
Stability |
0.03%T/5 min at 0%T 0.002 Abs/5 min at 0 Abs Measured in the visible region after 30-minute warm-up. |
|
Sample compartment |
Cartridge type, easy to mount and dismount, and easy to clean. Four-square-cell holder as standard. 100 mm in the maximum optical path length. |
|
Measurement with micro cell |
Possible without any attachment A micro cell, 10 mm in optical path length and 4 mm in inner width, is used. |
|
Analog output* |
0~100%T: 100mV, 1V 0~2 Abs: 100mV, 2V 0~3 Abs: 100mV, 3V |
|
Power consumption |
170W |
|
Power requirements |
AC 100/117/220/240V to be selected with a switch, 50/60Hz |
|
Dimensions |
505 W x 374 D x 240 H mm |
|
Weight |
19kg |
* An adapter is necessary for connection to a digital printer