Shimadzu TOC 5050 A
Objektnummer | B00009372 |
---|---|
ID-number | 009372 |
Object name | Shimadzu TOC 5050 A |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Specification
Analyte |
TC, IC, TOC (TC-IC), NPOC (non-purgeable organic carbon), POC (purgeable organic carbon: option) |
|
Method |
Combustion/non-dispersive infrared gas analysis method) |
|
Combustion temperature |
680ç C |
|
Measuring range |
50 ppb to 4000ppm (to 5000ppm for IC) (POC: Max 400 ppm) |
|
Average analysis time |
2 to 3 minutes for both TC and IC (4.5 minutes for TC and 3.5 min. for IC at the longest) |
|
Repeatability |
Standard deviation is less than 1% of full scale for the range less than 2000ppm to 4000ppm (from 2500ppm to 5000ppm for IC) |
|
Sample introduction |
Automatic injection via microliter syringe |
|
Sample injection volume |
4 to 250 µL |
|
Pretreatment for IC |
Automatic sparging function |
|
Carrier gas |
Cylinder of high purity air or oxygen; about 6kgf/cm 2 (7kgf/cm 2 max.) in supply pressure; 150 mL/min. in flow rate (300mL/min. including sparging) |
|
Data processing |
|
|
|
Detector signal |
Linearization, baseline correction, peak detection, and area calculation |
|
Data |
Calculation of concentration using one-point to four-point calibration curve; automatic selection of best calibration curve; store up to 18 calibration curves; automatic exclusion of anomalous value(s) and automatic re-analysis/re-calculation; calculation of standard deviation and coefficient of variation, automatic re-analysis with different measurement range and/or different sample volume when response goes off scale. |
|
Instrument control |
Aspiration, measurement, and injection sample; TC furnace temperature; ON/OFF of carrier gas and sparge gas. |
|
Other features |
Automatic selection of the optimum set of operation conditions; maintenance/self-diagnostics, warning of abnormality; timer for restarting from the running mode. |
Display |
White liquid crystal display with back-light, 640X400 dots, 88 characters x 22 lines. |
|
Printer |
Thermal, 240-dot graphic printer, 40 characters/line, 110 mm in chart width. External dot matrix: option. |
|
Ambient temperature requirements |
5ç to 35ç C |
|
Power requirements |
100, 110, 115, 120, 127, 220, 230, or 240V as ordered, ±10%, 50/60Hz, about 300 VA power consumption. (500 VA max.) |
|
Approx. dimensions and weight |
480 W X 525 D X 480 H mm (excluding projections), 46 kg |