HPLC-Systems

Shimadzu SIL-HTc Autosampler

Preis auf Anfrage
ID-number: 14193
Status: LabprocureLabprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.?
Shipping: 4-6 weeks
Description:
This refurbished Shimadzu SIL-HTc autosampler is in excellent condition. We have specialist expertise in analytical equipment. Specifications:. Sample injection system:. Full sample injection, variable sample injection system (no sample loss during injection). Adjustable range of injection volume:. 0.1 to 100 µL (standard) or 1 to 2000 µL (option). (0.1µL steps from 0.1 to 0.9 µL and 1 µL steps from 1 to 2000 µL). Sample preparation capacity:. With 1 mL vials: 350. With 1.5 mL vials: 140. With 4 mL vials: 100. With microtiter plates: 4 (96 wells: 284, 284 wells: 1536). With deep well plates: 4 (96 wells: 284, 284 wells: 1536). Injection volume repeatability:. RSD: max. 0.3% (at 10µL injection). Cross-contamination:. Max. 0.01% (when analyzing naphthalene). Injection volume accuracy:. Less than +/- 1% (50µL). Injection volume accuracy correction:. Possible. Number of injections:. 1-99 times per sample. Analysis time setting:. 0.01 – 9999.9 (0.1 minute increments up to 999.99 min., 0.1 minute increments over 1000 min.). Number of steps for injection conditions:. Maximum 102 steps. Sample aspiration speed:. 0.1-15 µL/s (0.1µL/s step for 0.1-0.9 µL/s, 1µL/s step for over 1 µL/s). Suction speed of the rinsing liquid:. 1-35 µL/s (1µL/s step). Maximum pressure:. Max. 20.0 MPa (by default the sample flow path is made of PEEK). Sample cooler:. Direct cooling method (at 4°C setting, room temperature must be less than 30°C and humidity less than 70%). Temperature range of setting:. 4 to 40°C (Cool down to 4°C when room temperature is up to 30°C and humidity is up to 70%). Ambient operating temperature range:. 4 to 35 °C Labprocure is responsible for this device.
Quotation
More Information
Objektnummer C00014193
ID-number 14193
Object name Shimadzu SIL-HTc Autosampler
Status Labprocure Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.
Manufacture SHIMADZU
Shipping 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Product group: HPLC

Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
lazyOwllazyOwl
Labprocure