Shimadzu SCL-10A
| Objektnummer | B00018296 |
|---|---|
| ID-number | 018296 |
| Object name | Shimadzu SCL-10A |
| Status | Stock unit |
Product group: HPLC-Miscellaneous
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer : Shimadzu
model : SCL-10A
annotation : Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
SCL-10Avp System Controller

This system controller is designed to be connected to the various units in the. Shimadzu LC-10N10Avp High Performance Liquid Chroma.tography series, and control their functions.
This controller centralizes control of a wide variety of system configurations, and can also permit fully operation.
- By means of specially designed fiber optic hnk interfa.ces, the controller can be connecte,d to the pump, column oven, detector, auto injector and fraction collector in the LC-10A/10Avp series.
Use of a sub-controlier will also permit the controlier to be connected to and control options such as special vaives and a heliurn degasser.
- An fiber optic link interface for connection to a Chrornatopac is supplied. This interface permits operation in tandem with a Chromatopac, or system control by
BASIC programs vvritten on the Chromatopac.
- An optional RS-232 cable can be used to connect the controiler to a PC, for PC
control. (When the controlier is under PC control, the fiber optic |inkin1erface
cannot be used.)
- The controller's LCD screen permits setting anaiysis conditions for the connected
devices , provides displays relating to control operation, and displays the status of each device for monitoring puposes during ana.lysis.
Additionally, the screen's graphic functions can provide graphic displays of scan data from the detector, chromatograms from the fraction collector, and other data that facilitate pararneters settings.
Display panel
LCD with back light 320 x 240 dots
Operation panel
Fixed function keys 22 keys
Keys
Variable function keys 5 keys
Flexible disk drive
Drive Double sided high density
Diskette 3.5" 2HD
Capacity (forrnatted) approx. 1.6 MByte.
Input terminals
External START signal Input (MAN.INJ iN) x1 (relay contact input) Actuated by time
program or by
EPiROR signal input (ALARM IN) x 3 (relay contact input) START, STOP or
ERROR
Common output terminals (EVENT1 ,2,3,4 ) x 4 (relay contact output) signals, as applicable
External power outlet control (AC REMOTE) x1 (for multiple terminal box )
Optical link (OFT LINK) connector x1 (for Chrornatopac)
RS-232C connector |x1 (for connection to PC)
REMOTE connector x 8 (for controlling HPLC units)
Compatible HPLC units
Pumps Up to 3 units
Auto injector 1 unit
Coiumn oven 1 unit
Detectors 1 or 2 units
Fraction collector 1 unit
Sub-controller valve intertace
1 unit
Equipment below can be connected via sub-controller (or valve Interface)
2-position rotary valves 2 units
6-position rotary valves 2 units
Solenoid valve unit 1 unit (cannot be connected via valve interface)
Helium degasser 1 unit (cannot be connected via valve interface)
Syringe unit 1 unit (cannot be connected via valve interface)
Parameter files
Analysis flies Number of flies 20
( parameters , Time program steps 400 (total of all flies)
time programs) Program time 0.01 - 9999.9 minutes
Fraction collector Nes Number of files 10
(
parameters
,
Time program steps
100 (total of all flies)
time programs)
Program time
0
,33
- 9999.9 minutes
Auto injector analytical Number of steps 102
sequence file
Auto injector Nurnber of files 20
pre-treatrnent files Program memory capac. 250 Bites for each file
Data files
Scan data files Number of files 3 (one for background, two for samples)
*Reception and display of scan data from SPD- 10A( V)vp possible
Chromatogram files Number of files 1 (for the fraction collector)
* Reception and display of chromatograms from FRC-10A possible
Pump control
Control modes Isocratic, high-pressure gradient, low-pressure
Gradient, constant pressure
Parameters Flow rate, pressure, concentration, upper and lower pressure limits l
Gradient proflies Step, linear and exponential functions (all at multiple levels)
Auto injector control
Parameters Sample injection, number of repeat lnjections, analysis duration or analysis file No., pre-treatment file No., fraction collector file No.
Column oven control
Parameters Oven temperature., upper temperature limit
Detector control
Parameters Detection wavelength, RANGE, time constant, lamp switching, scan conditions, etc.
Fraction collector control
Parameters Fractionation conditlons, etc., peak detection conditions, various analysis conditions
Data backup
All condition setting files (listed in 6. above) saved by battery backup if power failure occurs
Self-diagnosis and safety.measures
Memory check
Upper and lower pressure limits, upper temperature limit, monitoring of lamp current, motor speed, etc.
Operating conditions, dimensions, weight
Power supply voltage
Voltage range depends on Part No.:
Part No. 228-34350-91: 100-120V AC, 50 ,/ 60Hz, 320VA, 4A fuse
Part No. 228-34350-92: 100-120\ ,, AC, 50/6'0Hz, 320JA, 4A fuse
Part No. 228-34350-38: 220-240V AC, 50/60'Hz, 320VA, 2A fuse
Ambient temperature 4-35°C
Outer dirnensions Width 260 x depth 420 x height, 140 mm (excluding protruding parts)
Weight 6kg approx.