Shimadzu QP 2000

ID-number: 011659
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Shimadzu GC/MS-System QP 2000. Analysis unit with PC and Software. GC 14A.
siehe Storeview
More Information
Objektnummer B00011659
ID-number 011659
Object name Shimadzu QP 2000
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Shimadzu

Modell:            QP 2000

Kommentar:    Dokumente engl. (für IDNR 11659)

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.

INTRODUCTION

Shimadzu GCMS-QP2000 Gas Chromatograph/Mass Spectrometer System is a top performance desktop type GC/MS system which features exceptionally high degree of computerization and excellent ease of operation. It is sure to be effectively used in variety of routine works as well as for research and development.

Principle and Construction

The GCMS-QP2000 consists of the following three units:

(1) Gas chromatograph

(2) Interface

(3) Mass spectrometer

(1) Gas Chromatograph GC-14A

The GC-14A series Gas Chromatograph, which is controlled by microcomputer, is a multipurpose gas chromatograph exhibiting high performance. This GC unit has particularly distinguishing features such as small installation area requirements and large system expansion capabilities.

Specifications

Column oven

Dimensions of column compartment: 230 (W) X 140 (D) X 360 (H) mm

Length of columns to be         Stainless steel column           10m X 2

accommodated:

                                               Glass column 3m X 2

                                               Capillary column         100m X 1

Range of temperature setting:            Temperature;   -80~+399         1°C step

Rate of temperature rise;        0~40°C/min 0.1°C step

Constant temperature hold time; 0~655 min 0.1°C step

Program stages                      5 stages max.

Range of temperature control (with power voltage of 100V)

Range of linear temperature

increase:                                 30°C/min         150°C or less

                                               20°C/min         250°C or less

                                               10°C/min         330°C or less

                                               5°C/min           399°C or less

Lower-limit temperature:         When INJ and DET temperature is 300°C,

                                               room temperature + 15°C

                                               When INJ and DET temperature is 150°C,

                                               room temperature + 10°C

                                               Additional cryogenic equipment is required for controlling at           lower temperatures than those above.

Cooling speed:                        Approx. 9 min to reduce from 399°C to 100°C with room   temperature of 25°C.

                                               Approx. 14 min for reducing from 399°C to 50°C with room           temperature of 25°C

Detector oven

Range of temperature setting:            Room temperature ~399°C (in 1°C steps)

Control accuracy:                    ±0.02°C (Average)

TCD oven

Range of temperature setting:            Room temperature ~399°C (in 1°C steps)

Control accuracy:                    ±0.01°C

Sample injection port unit

Range of temperature setting:            Room temperature ~399°C

Control accuracy:                    ±0.1°C (Average)

Sample injection port unit (Either one of the following units is provided)

Single injection port unit:         For packed glass column, combination type of glass

                                               insert and on-column injection,          1 flow line

Dual injection port unit:            For packed glass column, combination of glass insert

                                               and on-column injection,        2 flow lines

Injection port unit for                Exclusive injection port for capillary analysis

for capillary columns:

Overheat protection circuit            3 circuits

1. 450°C-fixed independent protection circuit.

2. Protection circuit for which the upper-limit temperature can be set via key operation.

3. Overheat protection circuit by CPU abnormality detection

Combination of Detectors

1. Four detectors at maximum from among TCD, FID, ECD, FPD, and FTD can be simultaneously installed to the detector oven of the GC main body. Two TCD detectors cannot be set simultaneously.

2. Only two types of detector controllers (except FTD) can be installed simultaneously to the control section of the GC. Another unit should be applied for installing three or more detector controllers, or FTD.

(2) Interface

The interface is installed between the gas chromatograph (GC) and the mass spectrometer (MS) and connects the MS which operates under a high vacuum to the GC which operates under the atmospheric pressure.

The GCMS-QP2000 uses a direct connection interface; an analytical GC capillary column is directely connected to the MS. Capillary columns less than 0.25mm i.d. are recommended, those with an inside diameter of 0.2mm being most popularly used.

(3) Mass Spectrometer

Mass spectrometer

The apparatus to acquire the mass spectrum is the mass spectrometer. This apparatus is composed of the ion source for making ions and accelerating them in a specific direction, the analyzer for separating ions by the mass of them, and the detector for detecting separated ions. Besides, the vacuum system for evacuating the entire apparatus and spectrum recorder and data processor are needed.

As the method to separate the mass of ions, the one using a sector magnetic field is called a magnetic field type mass spectrometer, and the one using high frequency quaddrupole electric field isknown as the Q mass (or mass filter). Or the apparatus for generating ions in pulse form, and separating the mass by the difference in the flight time for passing a specific distance is called the time-of-flight (TOF) mass spectrometer. Besides, the Fourier transform mass spectrometer making use of ion cyclotron has come to be used practically.

Specifications

Performance

Mass range                             m/z10 - 900

Resolution                               2M (50% valley)

Detection limit                         1ng of methyl stearate, M + -(m/z298) with S/N ratio > 100

Scanning speed                      0.5, 1, 2, 4      256 seconds/full range, 10-step selection

Sample Inlet System

Gas chromatograph                Shimadzu GC-14A

Interface                                  Direct connection interface

Standard sample inlet:            PFTBA*2

Direct sample inlet*3               (Option)

Ion Source

Ionization method                    EI

Ionization voltage                     70eV

Maximum temperature            350°C

Analyzer/Detector Unit

Analyzer rods                          Hyperbolic quadrupole type*4

Detector                                  16-stage electron multiplier

Evacuation System

Evacuation pump                    A turbomolecular pump and a rotary pump

Baking                                     About 150°C

Operation system

Keyboard                                 Full keyboard with function keys

CRT                                         12" color CRT

Measurement

Mass spectra

MC (mass chromatogram)*5

Integrated TIC*6

SIM*7   8 channels x 5 sets (40 channels in total)

Software for Data Processing

Listing, tabulation, and edition of data

Drawing of mass spectra, MC, and SIM

Background subtraction of mass spectra

Area calculation of SIM

Library search*8 (option in QP2000, standard in QP2000A)

Quantitative calculation (option)


Hardware for Data Processing

Internal memory                      256K byte RAM

External memory                     Hard disk, 20M byte, 40 MB (option)

                                               Floppy disk, 1M byte

Printer                                      Dot matrix type

Installation Requirements

1) Power requirements

GC unit                                    100VAC, 17A, 50/60Hz

MS unit                                    100VAC, 15A, 50/60Hz

(Including the power for the CRT, keyboard, and printer.)

Allowable line voltage fluctuation

                                               90 - 110V; The equipment can operate.

                                               95 - 105V; The equipment operates to the specifications.

Provision for other line voltages is available by using optional transformer.

Grounding                                Less than 100Ω in the grounding resistance

2) Temperature and humidity

Temperature                           18 - 28°C

Humidity                                  40 - 70%

3) Dimensions and weights

GC                                     400Wx475Dx595H mm, about 40 kg

MS                                     560Wx575Dx430H mm, about 60 kg

Keyboard                           464Wx194Dx45H mm, about 1.5 kg

CRT                                   330Wx370Dx405H mm, about 11 kg

Printer                                403Wx344Dx90H mm, about 4.5 kg

Rotary pump                     411Wx160Dx236H mm, about 14 kg

Chart paper                       260Wx280D mm,

Power source terminal and earth terminal

The bench should have a top space of 2100W x 700D mm or larger.

Product group: GC / MS