HPLC-Systems

Shimadzu Nexera X2 UHPLC System Featuring LC-30AD

Preis auf Anfrage
ID-number: 14126
Status: LabprocureLabprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.?
Shipping: 4-6 weeks
Description:
The Shimadzu Nexera X2 is a flexible system design that enables a true fusion between UHPLC and HPLC technologies, enabling the use of Nexera This UHPLC system not only offers maximum speed, sensitivity, resolution, stability and reliability, but also a revolutionary i-PDeA separation technology and an i-DReC function that extends the dynamic range so that both concentrated and trace components are quantified simultaneously can be. The system includes:. Prominence SPD-M20A or Nexera X2 SPD-M30A photodiode array detector. DGU-20A degassing unit with solvent tray. two Nexera X2 LC-30AD liquid chromatographs. CBM-20A communication bus module. Nexera X2 SIL-30ACMP autosampler. Nexera X2 CTO-30A column oven,. PC with data. Specifications:. LC-30AD degassing unit. 3 or 5 lines (volume 400 ?L),. Flow rate range: 0.0001 to 10 mL/min. Flow rate precision: No more than 0.06% RSD or 0.02 min SD, whichever is greater. Gradient type: high pressure/low pressure mixed gradient. Gradient/Concentration Accuracy: ±0.5% (specific conditions). Maximum pressure: 130 MPa (0.0001 to 3 mL/min), 80 MPa (3.0001 to 5 mL/min), 22 MPa (5.0001 to 10 mL/min). SIL-30ACMP: . Injection method: needle-in-flow path,. Injection volume accuracy: ±1% (at 50 ?L injection, n = 10),. Injection volume range: 0.1 to 50 ?L (Option: 0.1 to 100 ?L),. Injection volume reproducibility: RSD: maximum 0.2% (at 10 ?L),. Sample capacity: Sample plate: 324 (1.5 mL), 576 (96-well MTP/DWP plates), 2304 (384-well MTP/DWP plates),. Control plate: 10 (1.5 mL),. Sample cooler: block cooling/heating, used together with dehumidification function, temperature range: 4 to 40°C. CTO-30A:. Oven capacity: Up to 2 - 150 mm columns. Temperature control range: room temperature ± 5 to 150°C, setting range 4 to 150°C Labprocure is responsible for this device.
Quotation
More Information
Objektnummer C00014126
ID-number 14126
Object name Shimadzu Nexera X2 UHPLC System Featuring LC-30AD
Status Labprocure Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.
Manufacture SHIMADZU
Shipping 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Product group: HPLC Systems

Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
lazyOwllazyOwl
Labprocure