JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Usually, laboratory and analysis devices are very exigent system with a very own specifications and requirements. Therefore, the startup of a laboratory device often rises the question how to assemble, adjust and to launch it.
We would be pleased to take over the professional installation of your laboratory devices!Please contact us.
Benefit from the installation by us in more than one way:
24 months legal warranty
60 days Labexchange Fullguarantee
Certificate of operativeness
The Labexchange right of return
Optional installation of equipment for immediate and safe use of equipment
Questions regarding this device
If you buy this item used instead of new, you save as much CO2 as driving 1590 km with a gasoline car.
The legal warranty period for our devices is 24 months from delivery date.
All used instruments of Labexchange are subject to a technical inspection before delivery and will be supplied only, when they function perfectly well. The verification and functionability is documented by a service report of an independent service company. The Labexchange Fullguarantee is 60 days from delivery date. Malfunctions occurring within the warranty period will be corrected by us free of charge. (Valid for countries within the EU and CH)
Our certificate of operativeness ensures a technically perfect condition.
You are on the safe side with our used laboratory and analysis systems! For even more security during the purchase, we are granting the Labexchange right of return.
Return your laboratory or analysis system simply without explanation.
Our special terms and conditions are to be applied:Labexchange right of return(https://www.labexchange.com/fileadmin/user_upload/pdf/downloads/en/Rueckgaberecht_08_18_E.pdf)
On demand, we verify the option of an extension of warranty for your device. If possible, the period of warranty is 6 months for 10 % extra charge and 1 year for 20 % extra charge on the list price. (Valid for DE, AT, CH, FR, NL, BE, LU, GB and IR)
Play it safe! We are pleased to offer you the installation of your laboratory equipment. Our qualified technicians install the device on your desired date in the laboratory, so that you can work quickly and safely with your new laboratory equipment.
The installation of the equipment by Labexchange brings further advantages. You thereby obtain a guarantee extension to 6 months and you have also the right to the Labexchange Repurchase Guarantee. You receive sensible laboratory equipment and analytical systems as well as much of the available laboratory hoods, already incl. installation.
* Required Fields
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country
Possible payment methods
Comment
DE, AT, CH
Payment by invoice, payment in advance
Payment by invoice is only possible for corporate clients.
NL, BE, LU
Payment by invoice is only possible for corporate clients
Other countries
Payment in advance
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
All articles are used articles, except an article is listed especially as a new device.
Status
Condition
Immediately available
Used
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.
Published
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.
New device
new
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.
Model: LC 10A
The following illustrations and descriptions are model-related and taken from brochures.
They do not reflect the scope of delivery of the system.
The exact scope of delivery can be found in the offer text.
The LC-10AD is a dual piston pump designed to improve accuracy and sensitivity when using a high performance liquid chromatograph.
In addition to a pump, an automatic or manual injector, column, injector holder, and detector are required for a high-performance liquid chromatography system. All these devices are supplied as additional special accessories.
Please note that these operating instructions are solely limited to the operation of the LC-10AD and the important accessories. As far as the operation of the optional accessories is concerned, please refer to the operating instructions for the respective devices.
1. Ultra-low flow pulsation solvent delivery and highly accurate gradient delivery
Compared with conventional models, the strength of the flow pulsation has been significantly reduced and the pulsation cycle is noticeably shortened. This was achieved by reducing the outflow volume to a micro volume of 10 liters per piston stroke and by using a high-speed piston. These properties allow the use of pulsation-sensitive detectors (eg differential refractometers and electrochemical detectors) in the high-sensitivity range. In addition, extremely precise gradient delivery is possible in the semi-micro volume range.
2. Variety of functions for gradient delivery
Two methods, the low and the high pressure method, are available for gradient delivery. The high-pressure gradient method is extremely accurate and has minimal delay, while the low-pressure gradient method allows solvent delivery with up to four liquids at low cost.
In addition, the control of these gradient delivery methods can be performed with two different system configurations. Either use the SCL-10A system controller or control the gradient delivery from the LC-10AD (without using a system controller).
3. Use of buffer solutions
The automatic flushing device on the back of the piston seal automatically cleans the piston. When using a high salt concentration buffer solution as the mobile phase, this device effectively prolongs the life of the piston seal.
1. Pump: Micro volume double piston pump (approx. 10 l/stroke)
2. Solvent Delivery Methods: Delivery at a constant flow rate or
with constant pressure.
a) Delivery with constant flow rate:
Flow Velocity Range:
0.001 - 5 ml/min (10 - 400 bar)
5,001 - 9,999 ml/min (10 - 200 bar)
Compliance with the set flow rate:
Within 2% or 2 l/min, whichever is greater
(0.01 - 5 ml/min, 10 - 400 bar, with water and room temperature of 20°C) except for areas of low pressure gradient delivery
Flow Velocity Accuracy: Within 0.3% (0.1 - 5 ml/min, 10 - 400 bar with water and room temperature of 20°C)
b) Feeding with constant pressure:
Pressure input range: 10 - 400 bar (at 1 bar intervals)
Maintaining the set pressure: Less than 10% or 10 bar, whichever is greater.
3. Pressure limit: high/low pressure
4. Pulsation dampener: Internal capacity of about 200 l.
5. Materials in contact with solvent: SUS 316 (stainless steel), Ruby, Sapphire, Teflon 9 9 graphite annealed, Hastelloy Ce, PEEK, Kahez KelF
6. Suction filter: Sieve size 10
7. Line filter: Sieve size 2, capacity approx. 200 1
Time program: Flow rate, pressure, EVENT and LOOP (program repetition). A total of 10 files and 320 steps.
9. Pressure reading accuracy: 2% or 5 bar, whichever is greater.
10. Piston seal cleaning flow line: Automatic cleaning is made possible by connecting the optional automatic rinsing device.
11. Dimensions: 260 x 150 x 420 (width x height x depth), but protruding components are not included.
12. Weight: 11kg
13. Operating temperature range: 5 - 35°C
14. Operating voltage: P/N 228-25000-93 : 200 - 250 VAC,
100W
High Pressure Gradient Specifications
1. SCL-10A controller
1) Number of mixed solvents: 2 or 3
2) Gradient profile: linear, step and exponential functions; they can consist of several steps.
3) Number of program steps: 20 files and 400 steps in total
4) Program time: 0.01 - 9999.9 min
5) Mixing ratio input area: 0 - 100% (in 0.1% steps)
6) Compliance with the entered mixing ratio: 1% (0 - 100%, 0.1 - 3m1/min, 10 - 400 bar, with a water - acetone mixture)
2.LC-10AD
1) Number of mixed solvents: 2
2) Gradient profile: linear and stairs; they can consist of several steps.
3) Number of program steps: 10 files and 320 steps in total
4) Program time: maximum 999.99 min (in 0.01 min increments)
6) Compliance with the entered mixing ratio: 1% (0 - 100%, 0.1 - 3 ml/min, 10 - 400 bar, with a water - acetone mixture)
Low Pressure Gradient Specifications
1) Number of mixed solvents: up to 4
5) Mixing ratio input range: 0 - 100% (in 0.1% increments)
6) Applicable flow rate range: 0.1 - 9.99 ml/min
6) Applicable flow rate range: 0.1 - 9,999 ml/min
Your Labexchange-Team will gladly help:
Christian Schmid Laboratory and analysis, Laboratory equipment, Life science
Hubert Sauter Spectroscopy, Chromatography