Shimadzu IR 470

ID-number: 002092
Status: Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
Shimadzu IR-spectrometer IR 470. With additional equipment IEEE-488 Interface and several quartz-küvettes. YoC: 1991.
Quotation
siehe Storeview
More Information
Objektnummer B00002092
ID-number 002092
Object name Shimadzu IR 470
Status Stock unit

Product group: Infrared spectrometers

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Shimadzu

Modell:            IR 470

Kommentar:    Dokumente dt.

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

Spezifikationen

Photometrisches                              Zweistrahliges Ratiogeraet, Proben- und

Messprinzip                                      Referenzstrahl mit unterchiedlicher Frequenz moduliert.

Lichtquelle                                         Globar mit automatischer Leistungskontrolle

Monochromator                                Littrow-Anordnung, 2 Gitter

Detektor                                            Hochempfindliches Vakuum-Thermoelement (mit KRS-5     Fenstern)

Drucker                                             Paralleler Thermodrucker

                                                         Variable Spreizung der

                                                         Ordinatenskalierung:    -500% - 500% T

                                                                                               -5.0 - 5.0 ABS

                                                         Abzissenskalierung:      x1, x2, x4, x8, x16

                                                                                               x 32, x64, x128

                                                         Gleichzeitiger Ausdruck des Spektrums mit Gitter ist            moeglich.

                                                         Hardcopy der Bildschirmanzeige ist moeglich

                                                         4 auswaehlbare Linienformen.

                                                         Moeglichkeit der Ausgabe mehrere Spektren in einem          Rahmen.

Bildschirm                                         12" Bildschirm, monochrom, mit Kippfuss

                                                         Parameter- oder Spektrumseite auswaehlbar.

                                                         Zooming-Funktion:

                                                         Ordinate: x1, x2, x4, x8

                                                         Abzisse : x1, x2, x4, x8, x16

                                                         Kapazitaet des Bildschirmspeichers: 10.000 Datenpunte

                                                         Einstellbarer Bereich der Ordinatenskalierung:

                                                         0 - 150% T

                                                         0 - 3.0 ABS

Wellenzahlbereich                            4000cm -1 - 400cm -1

Aufloesung                                        Bei normalen Messungen: 2.7cm -1 bei 1300cm -1 ,     getestestet mit CH 4 mit den Parametern W.NO SCALE     =x16, SPEED = SLOW, SLIT = AUTO-1

                                                         Bei optimierten Bedingungen: 0.8cm -1 bei 1000cm -1 ,            getestet mit NH 3 -Gas, SLIT = FIX

Wellenzahlgenauigkeit                      4.0cm -1 (4000 - 2000cm -1 )

                                                         1.5cm -1 (2000 - 400cm -1 )

Wiederholgenauigkeit                       2.0cm -1 (4000 - 2000cm -1 )

                                                         0.4cm -1 (2000 - 400cm -1 )

Wiederholgenauigkeit                       0,5% Transmission, mit Ausnahme des

der Transmission                             Wellenzahlbereiches, in dem Absorptionsbanden

                                                         von Wasserdampf existieren.

Registriergeschwindigkeit                6-stufig

                                                         AUTO

                                                         RAPID                       3:10 Min.

                                                         FAST                         5:45 Min.

                                                         MEDIUM                    12:00 Min.

                                                         SLOW                       32:00 Min.

                                                         ACCUMULATION      (1 - 200)

Wiederholungsmessungen              Wiederholungszahl: 1 - 100

                                                         Wartezeit                  0 - 60 Min.

                                                         Moeglicher Wellenzahlbereich:

                                                         4000 - 400cm -1

Spaltprogramm                                 5-stufig und fest

Gitterwechsel                                    Veraenderbar von 1400cm -1 bis 1100cm -1

Backup Speicher                              16 KByte, fuer

                                                         4 Parameterspeicher

                                                         1 Spektrum

                                                         4 Auto-scan-Programme

Backup Uhr                                       Jahr, Monat, Tag, Stunde, Minute

Auto-scan-Programm                       Standard

Datenverarbeitung                            Standard, Speicherbare Daten-Files: 9

                                                         davon:

                                                         8 Daten-Files a" 2000 Datenpunkte

                                                         1 Backup-File a" 2000 Datenpunkte